Biorem Inc. · TSXV:BRM
Biorem — BIOREM Technologies — Investor Presentation (February 2006)
34 slides from Biorem's investor presentation, February 2006

Slide 1: BIOSORBENS: Your Best Choice For Plant Odor, H2S & TRS Control
BIOSORBENSTM Your Best Choice For Plant Odor, H2S & TRS Control Richard Puntis, M.Sc. BIOREM Technologies Inc.

Slide 2: About BIOREM
About BIOREM Most Experienced Biofilter Company in N.A. Over 150 Worldwide Installations for VOCs & Odors Resources: Full Biotech Laboratory Monitoring & Service Program A Decade of Biotechnology Expertise Worldwide Representation Proven Systems (BASYSTM BIOFILTAIRTM) Wide range of c

Slide 3: What Is Biofiltration to BIOREM?
What Is Biofiltration…… to BIOREM? High Efficiency Removal and destruction of odorous compounds in contaminated or foul air Process occurs on a fixed bed of single layer homogenous engineered filter media Permanent BIOSORBENSTM Media has microbiologically active amigdales & surface area Redu

Slide 4: The Retro-Biofilter (Organic Media)
The Retro-Biofilter (Organic Media) (STOP! We don’t do it like this anymore!) Lateral Air Flow Piping 1-800-353-2087

Slide 5: The Retro-Biofilter: Too Many Problems!
The Retro-Biofilter….. Too Many Problems! Organic media has background odor Organic media can quickly decompose leading to: Compaction, shortened residence time, odor breakthrough Add more media, increases weight and compaction Poor moisture control, leading to bed dry out or patchiness

Slide 6: BREAKTHROUGH: BIOSORBENS
BREAKTHROUGH: BIOSORBENS™ First PERMANENT Inorganic Media In N.A. (Now that’s the way to do it!) Long lasting (>10 Year) No Compaction Low pressure drop (1”-2”) Consistent Performance Hydrophilic Mineral Core Buffers built in! Hydrophobic Components Good Biological Env’t High Surfa

Slide 7: Why BIOSORBENS Compared to Carbon or Lava
Why BIOSORBENS TM Compared to….. Carbon…… or……Lava…... Carbon is more expensive per pound High O&M costs because of need to replace regularly Or messy on-line regeneration with hazardous chemicals Only 30% effective regen cycle – media deteriorates quickly Works best in dry environment…..D

Slide 8: Benefits of BIOSORBENS
Benefits of BIOSORBENS TM Smaller More Compact System (¼ space!) Lower capital cost for biofilter reactor Single bed - easy to install & replace media Permanent Media – 10-YEAR Warranty Superior, predictable H2S, Odor & VOC removal Only biofilter system with predictive performance Very

Slide 9: The BASYS Patented Modular Biofilter
The BASYSTM Patented Modular Biofilter (Completely integrated, compact treatment from 300 cfm – 10,000 cfm) Duct BIOSORBENSTM Clean Air! inorganic media Optional pre-treatment FRP fan Stainless steel with VFD construction Recycled plastic slotted flooring 1-800-353-2087

Slide 10: BIOFILTAIR System
BIOFILTAIRTM System (Now that’s a better design – for 10,000 cfm 500,000 cfm!) Ground level BIOSORBENSTM CO2 Evolution inorganic media Gate entrance H2S resistant/epoxy coated concrete basin Strong Slotted Sub Floor Air flow 1-800-353-2087

Slide 11: Performance of BIOSORBENS Media in H2S Removal
FIGURE 4. PERFORMANCE OF BIOSORBENSTM MEDIA IN HYDROGEN SULPHIDE REMOVAL with 30 seconds-EBRT (Shock Loading; fluctuations in concentrations) 100 90 Input 80 Output : 30 sec EBRT 70 H2S (ppm) 60 50 40 30 20 10 0 355 356 357 358 359 360 361 362 363 364 365 Operation Time (hrs) 1-800-353-2087

Slide 12: Performance of BIOSORBENS Media (12 ppm inlet H2S)
FIGURE 1 . PERFORMANCE OF BIOSORBENSTM MEDIA with 20 second- EBRT (12 ppm average inlet H 2 S) 100 100.0 90 90.0 Input 80 80.0 RE%, 20 sec. EBRT 70 70.0 H2S (ppm) 60 60.0 RE% 50 50.0 40 40.0 30 20 30.0 10 20.0 0 10.0 0.0 10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0 90.0 100.0 Operation Time (hrs) 1-800-3

Slide 13: Performance of BIOSORBENS Media (39 ppm inlet H2S)
FIGURE 2 . PERFORMANCE OF BIOSORBENS TM MEDIA with 30 second-EBRT (39 ppm average inlet H2S) 100.0 100.0 90.0 90.0 80.0 80.0 70.0 70.0 H2S (ppm) 60.0 60.0 RE% 50.0 50.0 40.0 40.0 30.0 30.0 20.0 Input 20.0 10.0 RE%, 30 sec. EBRT 10.0 0.0 0.0 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340

Slide 14: Design Diagram for H2S (Model Predictions)
DESIGN DIAGRAM FOR H2S (Model Predictions) 1 2 3 4 100 100.00 5 6 99 7 98 8 97 90.00 9 96 10 95 11 94 80.00 12 93 13 92 14 91 70.00 15 90 16 89 60.00 17 EBRT=20 s 88 18 EBRT=30 s 87 50.00 19 EBRT=45 s 86 40.00 20 85 21 84 30.00 22 83 23 82 20.00 24 81 25 10.00 80 26 79 0.00 27 78 28 77 29 76 30 75 3

Slide 15: BIOSORBENS vs The Competition
BIOSORBENS TM VS THE COMPETITION! The following results were undertaken by MWH Consultants at the Hyperion WWTP, Los Angeles California, May 2003 Media Type RE% RE% BIOSORBENSTM 89 89 Lava Rock/Wood Chips 69 58 (Liquid nutrification added regularly) Bioscrubber 34 67 (Recirculation nutrient-rich liq

Slide 16: Analysis of Gas Samples for Volatile Sulfur Compounds
Table 1. The Analysis of Gas Sampling Bulb Samples for Volatile Sulfur Compounds BIOREM Technologies (April 3/03) ORTECH ID BIOSORBENS™ BIOSORBENS™ RE% (03-25180) MEDIA MEDIA Sample ID INLET OUTLET CONCENTRATION CONCENTRATION Dimethyl 11.40 1.27 90% Sulphide Results are reported in mole ppm and are

Slide 17: BIOSERVE Extended 10 Year Performance Guarantee
BIOSERVETM Extended 10 YEAR Performance Guarantee TM Total Biofilter System Responsibility Plant Operations BIOREM Media Tests Back Pressure Moisture Content Air Temperature Nutrient Level Flow Rate pH RH Fines Content bacterial enumeration bacterial speciation 1-800-353-2087

Slide 18: BIOSERVE Monitoring/Service Program
BIOSERVE TM Monitoring/Service Program Level 1 – (Standard) On site manual monitoring – daily readings by operator 24 hour Dedicated Service Manager (?DL). Level 2 – Option Semi-automated Remote monitoring with manual adjustment alert (eg Rothsay) Level 3 – Option – Fully automated 2

Slide 19: Centre Street WWTP, Mt. Pleasant, SC
Centre Street WWTP Mt. Pleasant, SC 1-800-353-2087

Slide 20: Frito Lay, Detroit, Michigan
Frito Lay Detroit, Michigan 1-800-353-2087

Slide 21: City of Headingly, MB
City of Headingly, MB 1-800-353-2087

Slide 22: Whipple Road Pump Station, Mt. Pleasant, SC
Whipple Road Pump Station Mt. Pleasant, SC 1-800-353-2087

Slide 23: City of Montpelier, VT Septage Receiving Area
City of Montpelier, VT Septage Receiving Area 1-800-353-2087

Slide 24: City of Broomfield, Colorado Main WWTP
City of Broomfield, Colorado Main WWTP 1-800-353-2087

Slide 25: Coleman Blvd. Pump Station, Mt. Pleasant, SC
Coleman Blvd. Pump Station Mt. Pleasant, SC 1-800-353-2087

Slide 26: Premier Candles, Mississauga Ontario
Premier Candles Mississauga Ontario 1-800-353-2087

Slide 27: Louisville, MSD, Kentucky
Louisville, MSD, Kentucky 1-800-353-2087

Slide 28: Jacksonville Electric Auth., Jacksonville, FL
Jacksonville Electric Auth. Jacksonville, FL 1-800-353-2087

Slide 29: City of Wild Dunes, SC
City of Wild Dunes, SC 1-800-353-2087

Slide 30: Jefferson County, Birmingham, AL
Jefferson County Birmingham, AL 1-800-353-2087

Slide 31: City of La Malbaie, Quebec, Canada
City of La Malbaie, Quebec, Canada 1-800-353-2087

Slide 32: Maple Leaf Foods: Worlds Largest - 250,000 CFM!
Maple Leaf Foods Worlds Largest - 250,000 CFM! 1-800-353-2087

Slide 33: Benefits of BIOREM VS The Competition
Benefits of BIOREM VS The Competition Single Homogenous Media vs Multiple Layers Permanent Media - No Decomposing Woodchips vs Woodchip Layer Predictive Curves & Tons of Data vs Little or No Data Industry’s Longest Warranty vs 1 yr or 5 year Manufactured Media vs Stone/Carbon, Clay/Lava/Co

Slide 34: For More Information
For More Information…. Website: www.biorem.biz Richard Puntis PH: (519) 767-9100 x 224; FAX: (519) 767-1824 Email: rpuntis@biorem.biz 1-800-353-2087
Source: Internet Archive copy of biorem.biz
More decks from Biorem Inc.
Investor Presentation (February 2022)18 slides · February 2022
BIOREM Technologies — Investor Presentation (February 2006)34 slides · February 2006
BIOREM Technologies — Investor Presentation (January 2006)16 slides · January 2006
BIOREM Technologies — Missouri WEA 200428 slides · March 2004
BIOREM Technologies — Investor Presentation (June 2003)19 slides · June 2003
BIOREM Technologies — Technical Presentation (August 2002)32 slides · August 2002