Biorem Inc. · TSXV:BRM

Biorem — BIOREM Technologies — Investor Presentation (June 2003)

19 slides from Biorem's investor presentation, June 2003

  1. Slide 1: BIOSORBENS Biofilter: Your Best Choice For Plant Odor & H2S Control

    BIOSORBENSTM BIOFILTER: Your Best Choice For Plant Odor & H2S Control Richard Puntis, M.Sc. BIOREM Technologies Inc.

  2. Slide 2: About BIOREM

    About BIOREM ¾ Most Experienced Biofilter Company ¾ Over 40 Installations for VOCs & Odors ¾ Exclusively Biofiltration ¾ Resources: ¾ Full Biotech Laboratory ¾ Monitoring & Service Program ¾ (Bio)Technology Contractors ¾ Regional N.A. – Wide Representation ¾ Proven Systems ¾ Wide range of contaminan

  3. Slide 3: Odor Control Technologies - Your Choices

    Odor Control Technologies - Your Choices ¾ Thermal oxidation (Incineration) ¾ Adsorption (Granular Activated Carbon) ¾ Condensation (industry) ¾ Chemical Scrubbing ¾ Biotrickling Filter (Bioscrubbing) ¾ Biofiltration 1-800-353-2087

  4. Slide 4: Operating Ranges of the Technologies

    Operating Ranges of the Technologies 50000+ Biofiltration 40000 Airflow ACFM 30000 Incineration/Oxidation 20000 Scrubbers 10000 Adsorption Condensation 0 0 250 500 750 1000+ Concentration, ppmv

  5. Slide 5: What Is Biofiltration?

    What Is Biofiltration? ¾ Removal and destruction of odorous compounds in contaminated or foul air ¾ Occurs on a fixed bed of filter media ¾ Media has microbiologically active surface area ¾ Reduces odors and VOCs to H2O and CO2 ¾ Complete destruction (not phase transfer) ¾ Self regenerating ¾ No was

  6. Slide 6: Dynamics of Biofiltration Efficiency & Kinetics

    Dynamics of Biofiltration Efficiency & Kinetics Kinetics (determines removal efficiency) ¾ Biodegradability & Biodegradation Rate Residence Time (determines biofilter size) ¾ Solubility & Solubilization Rate ¾ Conventional Biofilter (2 steps) ¾ Solubilization-Biodegradation ¾ BIOSORBENSTM Biofilter

  7. Slide 7: Desired Air Quality & Optimum Design Parameters

    Desired Air Quality & Optimum Design Parameters ¾ Temperature - 12°C/50°F - 38°C/110°F ¾ pH - 6-8 ¾ RH - 98% ¾ Low particulate loading ¾ Known contaminant concentration ¾ Selection of best (inorganic) Media ¾ Location & space for system ¾ Monitoring & service contract 1-800-353-2087

  8. Slide 8: Where is Biofiltration Used?

    Where is Biofiltration Used? ¾ Biofiltration is becoming more widely used to control odors & H2S and VOCs at rendering, pet-food, food, composting WWTP, pumping stations and many other facilities: ¾ American Proteins Mars Doane Petcare ¾ Maple Lodge Farms CBP Minneapolis WWTP ¾ Cold Springs Farms Co

  9. Slide 9: The Traditional (Retro!) Organic Media, Header-Lateral Biofilter System

    The Traditional (Retro!) Organic Media, Header-Lateral Biofilter System Lateral Air Flow Piping 1-800-353-2087

  10. Slide 10: The Traditional Organic Media Biofilter System – The problems

    The Traditional (1st Generation) Organic Media, Header-Lateral Biofilter System – The problems ¾ Typical 60 seconds residence time means HUGE space requirement (4xbigger than with BIOSORBENSTM!) ¾ Organic media has background odor ¾ Organic media decomposes over time leading to: ¾ Compaction, shorte

  11. Slide 11: BREAKTHROUGH: BIOSORBENS Inorganic Media

    BREAKTHROUGH: BIOSORBENS™ Inorganic Media ¾ Long lasting (>10 Year) ¾ No compaction ¾ Low pressure drop (1”-2”) ¾ Consistent Performance ¾ Hydrophilic mineral cores ¾ Buffers built in ¾ Hydrophobic components ¾ Good biological env’t ¾ Very high surface area ¾ pH neutral ¾ Low volume required ¾ Regen

  12. Slide 12: Monitoring/Service Program

    Monitoring/Service Program ¾ Plant Operations ¾ BIOREM Media Tests ¾ Back Pressure ¾ Moisture Content ¾ Air Temperature ¾ Nutrient Level ¾ Flow Rate ¾ pH ¾ RH ¾ Fines Content ¾ bacterial enumeration ¾ bacterial speciation 1-800-353-2087

  13. Slide 13: Performance of BIOSORBENS Media (12 ppm inlet H2S)

    FIGURE 1 . PERFORMANCE OF BIOSORBENSTM MEDIA with 20 second- EBRT (12 ppm average inlet H 2 S) 100 100.0 90 90.0 Input 80 80.0 RE%, 20 sec. EBRT 70 70.0 H2S (ppm) 60 60.0 RE% 50 50.0 40 40.0 30 20 30.0 10 20.0 0 10.0 0.0 10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0 90.0 100.0 Operation Time (hrs) 1-800-3

  14. Slide 14: Performance of BIOSORBENS Media (39 ppm inlet H2S)

    FIGURE 2 . PERFORMANCE OF BIOSORBENSTM MEDIA with 30 second-EBRT (39 ppm average inlet H2S) 100.0 100.0 90.0 90.0 80.0 80.0 70.0 70.0 H2S (ppm) 60.0 60.0 RE% 50.0 50.0 40.0 40.0 30.0 30.0 20.0 Input 20.0 10.0 RE%, 30 sec. EBRT 10.0 0.0 0.0 200 210 220 230 240 250 260 270 280 290 300 310 320 330 340

  15. Slide 15: Performance of BIOSORBENS Media in Hydrogen Sulphide Removal

    FIGURE 4. PERFORMANCE OF BIOSORBENSTM MEDIA IN HYDROGEN SULPHIDE REMOVAL with 30 seconds-EBRT (Shock Loading; fluctuations in concentrations) 100 90 Input 80 Output : 30 sec EBRT 70 H2S (ppm) 60 50 40 30 20 10 0 355 356 357 358 359 360 361 362 363 364 365 Operation Time (hrs) 1-800-353-2087

  16. Slide 16: BIOFILTAIR System

    BIOFILTAIRTM System CO2 Evolution Ground level BIOSORBENSTM inorganic media Gate entrance H2S resistant/ epoxy coated concrete basin Slotted Sub Floor Air flow 1-800-353-2087

  17. Slide 17: The BASYS Modular Biofilter

    The BASYSTM Modular Biofilter Duct BIOSORBENSTM inorganic media Air Flow Optional pre-treatment FRP fan with VFD Stainless steel consutruction Recycled plastic slotted flooring 1-800-353-2087

  18. Slide 18: Case Studies

    Case Studies: Purina Mills - 50,000 cfm Friskies Petcare - 35,000 cfm Central Byproducts – 15,000 cfm City of Mt Pleasant – 2,000 cfm 1-800-353-2087

  19. Slide 19: For More Information …

    For More Information … Richard Puntis, M.Sc. BIOREM Technologies Inc. 7496 Wellington Road 34 RR#3 Guelph ON N1H 6H9 (519) 767-9100 X 224 (519) 767-1824 rpuntis@bioremtech.com www.bioremtech.com

BIOREM Technologies — Investor Presentation (June 2003) on 6ix