Terramin Australia Limited · ASX:TZN
Terramin Australia — Technical Presentation (January 2018)
24 slides from Terramin Australia's technical presentation, Jan 30, 2018

Slide 1: Bird-in-Hand Gold Mine Acoustics
Bird-in-Hand Gold Mine Acoustics

Slide 2: Content
Content – Why are WSP involved? – Acoustic terminology – Baseline noise monitoring 2 – Project noise limits and regulatory noise criteria – Steady state noise (constancy)

Slide 3: Why are WSP involved?
Why are WSP involved? – Baseline noise monitoring and the noise impact assessment was undertaken by AECOM – Simon Moore was previously employed by AECOM and moved to WSP in September 2017 3 – Simon was the lead acoustic engineer for the baseline noise monitoring and noise impact assessment while he

Slide 4: Acoustic terminology
Acoustic terminology – Relevant terms: Leq, L90, Lmax Example – Other terms: Lmin, L10, L50 (median) 50 52 55 57 60 4 L90 50.8 Median (L50) 55.0 Average 54.8 Energy Average (Leq) 56.2 L10 58.8

Slide 5: Baseline noise monitoring
Baseline noise monitoring – Baseline noise monitoring was undertaken during September – October 2014, February – April 2015 and February – March 2016 5 – The baseline noise monitoring was undertaken at 4 locations – Baseline noise monitoring was delayed due to earthworks being undertaken for the con

Slide 6: Monitoring locations figure
Baseline noise monitoring – The locations in this figure are incorrect 6

Slide 7: Baseline noise monitoring
Baseline noise monitoring From: Mathew Daniel [maito:MtDaniel@Terrami } Sent: Thursday, 11 September 2014 11:35 AM To: Moore, Simon Cc: Katy Fechner Subject: RE: BIH Noise Monitoring ‘Yes, lets do this Simon, the rockbreaking has stopped. I'll be in Perth next week, but Katy can assist if needed. Ma

Slide 8: Baseline noise monitoring
Baseline noise monitoring 24 February 2014 8

Slide 9: Baseline noise monitoring
Baseline noise monitoring 30 September 2014 9

Slide 10: Baseline noise monitoring
Baseline noise monitoring 5 January 2015 10

Slide 11: Baseline noise monitoring
Baseline noise monitoring 6 February 2016 11

Slide 12: Baseline noise monitoring
Baseline noise monitoring 12

Slide 13: Baseline noise monitoring
Baseline noise monitoring 13

Slide 14: Project noise limits and regulatory criteria
Project noise limits and regulatory criteria – Area is zoned as Watershed (Primary Production) Zone within the Onkaparinga Valley Policy Area (Adelaide Hills Council Development Plan) – Noise source (Terramin BiH Gold Mine) and surrounding noise 14 sensitive receivers are all located within this zon

Slide 15: Project noise limits and regulatory criteria
Project noise limits and regulatory criteria – This is a development under the Mining Act 1971 – If this were a proposed new development under the Development Act 1993, the applicable noise criteria would be further reduced by 5 dBA. The purpose is to allow for multiple noise sources in the area. 15

Slide 16: Project noise limits and regulatory criteria
Project noise limits and regulatory criteria – Furthermore, Terramin are voluntarily adopting the requirement to achieve a noise level 5 dBA lower than required by the Noise EPP for operation of the mine – Therefore the project noise limits are 52 dBA during the day and 16 45dBA at night – Terramin

Slide 17: Project noise limits and regulatory criteria
Project noise limits and regulatory criteria 17

Slide 18: Steady state noise
Steady state noise – Many noise sources are steady state, and already exist in the background noise environment, such as: – Air conditioners – Ventilation fans – Pumps 18 – The Noise EPP recognises that some noises are more annoying than others. Noises with annoying characteristics are: – Modulating

Slide 19: Steady state noise
Steady state noise – Continuous steady state noise is not considered to be an annoying characteristic, and as such is not penalised under the Noise EPP – Steady state noise sources included in the proposed mine include: – Ventilation fans – Water pumps* 19 – Air compressors* – Air conditioning plant

Slide 20: Steady state noise
Steady state noise – Noise model has been checked to determine the contribution from the continuous noise sources – (primary vent shaft, magazine vent shaft, raw water plant, water treatment plant, wash down pump and workshop air compressor) 20 – Highest predicted noise level from the continuous noi

Slide 21: Steady state noise
Steady state noise 21

Slide 22: R12 continuous vs background noise level
Steady state noise – R12 continuous noise level vs background noise level at Location 2 22

Slide 23: R3 continuous vs background noise level
Steady state noise – R3 continuous noise level vs background noise level at Location 4 23

Slide 24: R14 continuous vs background noise level
Steady state noise – R14 continuous noise level vs background noise level at Location 1 24
Source: Internet Archive copy of terramin.com.au
More decks from Terramin Australia Limited
Shareholder Meeting (May 2026)15 slides · May 2026
Shareholder Meeting (May 2025)12 slides · May 2025
Shareholder Meeting (May 2022)12 slides · May 26, 2022
Investor Presentation (October 2019)23 slides · Oct 31, 2019
Investor Presentation (October 2019)22 slides · Oct 30, 2019
Technical Presentation (June 2019)20 slides · June 2019