BacTech Environmental Corp. · CSE:BAC

BacTech Environmental — Investor Presentation (July 2024)

30 slides from BacTech Environmental's investor presentation, July 2024

  1. Slide 1: Q3 2024 Corporate Presentation: Our Bugs Eat Rocks!

    Slide 1: Q3 2024 Corporate Presentation: Our Bugs Eat Rocks!

    CSE: BAC | OTCQB: BCCEF | FRA: 0BT1 | BACTECHGREEN.COM Q3 2024 CORPORATE PRESENTATION OUR BUGS EAT ROCKS!

  2. Slide 2: Legal Disclaimer

    Slide 2: Legal Disclaimer

    LEGAL DISCLAIMER This presentation contains certain forward-looking statements within the meaning of Canadian securities legislation (the “Forward-looking Statements”) and within the meaning of Section 21E of the United States Securities Exchange Act of 1934, as amended. Although the Company believe

  3. Slide 3: Commercially Proven Cleantech Company

    Slide 3: Commercially Proven Cleantech Company

    COMMERCIALLY PROVEN CLEANTECH COMPANY Focused on sustainable mining and environmental remediation bioleaching technology Commercially Proven Environmentally Friendly Favourable Macroeconomics Over 30 years of R&D, millions Bioleaching plants process toxic Ecuadorian artisanal and small invested, and

  4. Slide 4: The Problem: Toxic Concentrates and Tailings

    Slide 4: The Problem: Toxic Concentrates and Tailings

    THE PROBLEM …and the CAUSE of Toxic Concentrates Toxic Elements Released Expensive Reclamation and and Tailings into Atmosphere Remediations High arsenic concentrates are Pyrometallurgical processing Billions are spent every year on generally burned and pollute the releases arsenic trioxide and sulf

  5. Slide 5: Sulfides are the Glue of Nature

    Slide 5: Sulfides are the Glue of Nature

    THE PROBLEM Sulfides are the GLUE of nature… Millerite SPHALERITE Arsenopyrite COVELLITE Chalcopyrite PYRITE Galena Molybdenite MARCASITE Pyrrhotite Chalcocite 5 BACTECHGREEN.COM

  6. Slide 6: The Solution: Bioleaching

    Slide 6: The Solution: Bioleaching

    THE SOLUTION Bioleaching AKA Bacterial Oxidation Our Bugs Eat Rocks! BacTech Environmental is one of 2 companies worldwide with the expertise for vat bioleaching as an alternative to smelting/roasting. How? We like to use the analogy of a brick wall where the sulfides are the mortar holding everythi

  7. Slide 7: Sustainability at Our Core

    Slide 7: Sustainability at Our Core

    SUSTAINABILITY AT OUR CORE BACTERIA The bacteria are naturally occurring and harmless to the environment and WATER human health Efficient recycling of water from the process HEAVY METAL RECOVERY Toxic heavy metals, like arsenic, are EMISSIONS converted into stable environmentally No toxic gaseous em

  8. Slide 8: Ecuador Bioleaching Facility

    Slide 8: Ecuador Bioleaching Facility

    ECUADOR BIOLEACHING FACILITY THE FIRST DOMINO Substantial Revenues within 12 months 8

  9. Slide 9: Why Ecuador?

    Slide 9: Why Ecuador?

    WHY ECUADOR? Providing environmentally friendly processing locally and with positive local economic impact as BacTech can offer much better prices to miners. Full support from the Ecuadorian Ministry of Artisanal and Small Miners and the Ministry of Mines. Potential to become a regional processing h

  10. Slide 10: Tenguel Project

    Slide 10: Tenguel Project

    TENGUEL PROJECT BacTech is working to construct an owner operated Project Milestones 50 TPD bioleach processing facility in Tenguel, Ecuador. Bioleach Test Work The project is at an advanced stage and expected to begin construction once financing is secured. Bankable Feasibility Study Land Acquisiti

  11. Slide 11: Milestones

    Slide 11: Milestones

    MILESTONES April 2021 February 2022 October 2022 July 2023 November 2023 Carried out test work Completed Bankable Received Received an 80% rating Received on five samples that Feasibility Study Environmental (very good) from Consultation produced 96.2% gold showing US$17M in Impact Study (EIS) Moody

  12. Slide 12: Tenguel Project – Phase 2

    Slide 12: Tenguel Project – Phase 2

    TENGUEL PROJECT – PHASE 2 • Part of the IPA was BacTech’s commitment to build a Phase 2 of the project • The technology is modular, so expansion is straight forward • Expected total production >100,000 oz. per annum • Total market in Ponce area is 250 TPD of concentrate • Estimated CAPEX is US$60M,

  13. Slide 13: Investment Protection Agreement

    Slide 13: Investment Protection Agreement

    INVESTMENT PROTECTION AGREEMENT • Historic agreement signed on April 28, 2022, with the Government of Ecuador. • Covers up to US$75M in investment into Ecuador extending to any plant and operations expansions. • Under the IPA agreement specific protections relate to investor rights and guarantees su

  14. Slide 14: Economic Sensitivity

    Slide 14: Economic Sensitivity

    ECONOMIC SENSITIVITY Au Price NPV (5%) IRR EBITDA $1,600 USD $60.7M 58.0% $10.9M Annually $1,700 USD $68.0M 63.6% $11.9M Annually $1,800 USD $75.4M 69.3% $12.9M Annually $1,900 USD $82.7M 74.9% $13.9M Annually $2,000 USD $90.1M 80.5% $14.9M Annually $2,100 USD $97M 86% $15.9M Annually 14 BACTECHGREE

  15. Slide 15: BacTech Team

    Slide 15: BacTech Team

    BACTECH TEAM MANAGEMENT Board of Directors Ross Orr David Tingey Louis R. Nagy Dr. Paul C. Miller Kate Castro Bernardo Brito President and CEO Chief Operating Officer Chief Financial Officer VP Technology VP Environmental Country Manager, Ecuador BOARD OF DIRECTORS Timothy Lewin Ross Orr Walter Cimo

  16. Slide 16: Capitalization Structure

    Slide 16: Capitalization Structure

    CAPITALIZATION STRUCTURE As at January 1, 2024 Insiders, Management and Basic Shares Outstanding 193,035,333 Strategic Shareholders Public Reserved for Issuance 33,333,000 (Options & Warrants) Fully Diluted 226,368,033 Market Capitalization C$13.5M ($0.07) 51% 49% Average Daily Volume 80,000+ 52 Wee

  17. Slide 17: Pyrrhotite Tailings Treatment

    Slide 17: Pyrrhotite Tailings Treatment

    PYRRHOTITE TAILINGS TREATMENT 0 WASTE FROM TAILINGS SECOND OPPORTUNITY ~US$13-$15B of Nickel Ready for Recovery 17

  18. Slide 18: Sudbury Basin Market Opportunity

    Slide 18: Sudbury Basin Market Opportunity

    SUDBURY BASIN MARKET OPPORTUNITY In the Sudbury basin of Ontario, there is a vast resource of approximately 80-100M tonnes of 0.8% Ni-bearing pyrrhotite Assumptions: Nickel $16,000 tailings. Pyrrhotite consists of up to 60% Iron and 30% Sulphur in addition to cobalt, copper and nickel. BacTech has p

  19. Slide 19: 0 Waste from Tailings

    Slide 19: 0 Waste from Tailings

    0 WASTE FROM TAILINGS • BacTech has filed a provisional patent Project Milestones application for a novel bioleaching process relevant to the treatment of Provisional Patent Filed pyrrhotite tailings for iron, sulphur and nickel-cobalt recovery. Stakeholder Identification • New Patent details electr

  20. Slide 20: Direct Production of Iron from Tailings

    Slide 20: Direct Production of Iron from Tailings

    DIRECT PRODUCTION OF IRON FROM TAILINGS • Addition to existing patent application • Concept of electrowinning iron directly from bioleach liquor • Direct shipment of Iron to end user • Production of ammonia sulphate fertilizer from contained sulphur • Precipitate of nickel/cobalt • Precipitate of co

  21. Slide 21: Investment Summary

    Slide 21: Investment Summary

    INVESTMENT SUMMARY • One of 2 companies worldwide with commercial applications for bioleaching Market • Focused on high-arsenic gold concentrates produced by artisanal and small miners Position • Environmentally friendly process • EBITDA margin of 25-30% • Low CAPEX to EBITDA ratio Economics • ~US$6

  22. Slide 22: Appendix

    Slide 22: Appendix

    BacTtech APPENDIX 22

  23. Slide 23: Tenguel, Ecuador Plant Flowchart

    Slide 23: Tenguel, Ecuador Plant Flowchart

    AREA 100 20T FRESH WATER BIN 1.88 4.32 0.44 0.10 95.0 0.10 1.98 3.705 0.53 MILL TENGUEL, ECUADOR PLANT FLOWCHART VIBRATING FEEDER 0.11 MILL CONVEYOR 1.25 AIR COMPRESSOR TRASH SCREEN 1.88 4.32 0.44 0.42 2.30 45.00 2.30 1.88 4.32 0.44 4.18 1.53 2.73 0.21 90.0 0.21 NaOH 2.09 3.243 0.64 12.70 SAMPLER WA

  24. Slide 24: Tenguel, Ecuador Plant Flowchart

    Slide 24: Tenguel, Ecuador Plant Flowchart

    FROM SURGE TANK 12.23 AREA 200 0.05 AREA 100 NUTRIENTS 0.06 5% H2SO4 Mass ANTIFOAM 1.99 4.32 0.46 14.11 14.10 14.11 16.10 1.10 14.57 FEEDBOX TENGUEL, ECUADOR PLANT FLOWCHART LOW PRESSURE AIR FROM BLOWERS COOLING WATER BACK-UP PRIMARY PRIMARY PRIMARY INOC REACTOR REACTOR REACTOR #1 #2 #3 -0.28 EVAPOR

  25. Slide 25: Tenguel, Ecuador Plant Flowchart

    Slide 25: Tenguel, Ecuador Plant Flowchart

    WASH WATER AREA THICKENERS CCD WASH AND S/L SEPARATION 0.83 3.05 0.27 CCD THICKENER 14.66 5.36 14.66 #3 15.49 1.04 14.93 FROM BIOX AREA 200 TENGUEL, ECUADOR PLANT FLOWCHART PM - 02 CCD THICKENER #2 WASH WATER UPON REQUIREMENT 13.12 PM - 01 CCD THICKENER #1 PM - 03 TO AGL AREA 400 0.83 3.05 0.27 PROC

  26. Slide 26: Tenguel, Ecuador Plant Flowchart

    Slide 26: Tenguel, Ecuador Plant Flowchart

    FROM BIOX - AREA 300 THICKENER CCD#3 UNDERFLOW AREA 400 0.83 3.05 0.27 1.54 35.0 1.54 2.37 1.308 1.81 CAKE STOCK TANK PUMP TENGUEL, ECUADOR PLANT FLOWCHART FROM BARREN SOLUTION AREA 500 - MC 0.83 3.05 0.27 0.36 70 0.36 1.19 1.883 0.63 0.89 HORIZONTAL FILTER LIME SOLUTION LIME MIXING TANK TO NEUTRALI

  27. Slide 27: Tenguel, Ecuador Plant Flowchart

    Slide 27: Tenguel, Ecuador Plant Flowchart

    AREA 500 TO ATMOSPHERE SOLUTION m3/hr 9.5 gpm 2.15 AUTO-JET VACCUM TANK TENGUEL, ECUADOR PLANT FLOWCHART FILTER FROM 400 PREGNANT SOLUTION #1 WATER SEAL VACCUUM PUMP DIATOMITE ZINC DUST AUTO-JET FILTER #2 REAGENT PM - 01 DIATOMITE SOLUTION PUMP DIATOMITE CONDITIONING TANK PRECIPITATION CONE NON-LINE

  28. Slide 28: Tenguel, Ecuador Plant Flowchart

    Slide 28: Tenguel, Ecuador Plant Flowchart

    AREA 600 LIMESTONE 4.2 2.8 1.5 6.3 40.0 6.3 4.2 2.8 1.5 10.5 1.34 7.8 2.1 67.0 2.1 AGUA FRESCA 6.3 1.76 3.6 10.5 Rc = 200% 4.2 2.8 1.5 12.6 2.8 4.5 100.0 8.4 60.0 8.4 21.0 1.63 12.9 6.3 NUTRIENT NUTRIENTS TENGUEL, ECUADOR PLANT FLOWCHART 4.2 2.8 1.5 BAG HOIST SULPHURIC ACID 16.8 20.0 16.8 21.0 1.15

  29. Slide 29: Tenguel, Ecuador Plant Flowchart

    Slide 29: Tenguel, Ecuador Plant Flowchart

    AREA 700 22.50 450.00 COOLING WATER TENGUEL, ECUADOR PLANT FLOWCHART VENDOR PACKAGE COOLING COOLING COOLING TOWER 1 TOWER 2 TOWER 3 12,000 BIOX TANKS ANTISCALANT AREA 200 DOSING PUMP NEUTRALIZATION TANKS AREA 300 LOW PRESSURE AFTER BLOWERS COOLERS ANTISCALANT DRUM VENDOR PACKAGE COOLING WATER PUMP 1

  30. Slide 30: BacTech Environmental Corporation Contact

    Slide 30: BacTech Environmental Corporation Contact

    CSE: BAC | OTCQB: BCCEF | FRA: 0BT1 | BACTECHGREEN.COM BacTech Environmental Corporation Suite 409, 37 King St. East Toronto, Ontario M5C 1E9 Ross Orr, President & CEO borr@bactechgreen.com Office: 416-813-0303 ext. 222 30

Source: Internet Archive copy of bactechgreen.com

More decks from BacTech Environmental Corp.

All 10 BacTech Environmental decks