  1. Slide 1: Anteris Technologies

    ANTERIS TECHNOLOGIES January 2026

  2. Slide 2: Disclaimer

    Disclaimer This presentation has been prepared by Anteris Technologies Global Corp. (“Anteris,” the “Company,” “we” or “us” or "our"). This presentation, and its contents and the accompanying discussion with management are confidential and may not be further copied, distributed or passed on, directl

  3. Slide 3: 3

    3

  4. Slide 4: Anteris Technologies – Executing on strategy

    Anteris Technologies – Executing on strategy Building commercial readiness for a new class of TAVR that mimics a healthy aortic valve 1 Successfully priced U.S. IPO and listed on Nasdaq in December 2024 - Enhancing liquidity and visibility in the world’s largest healthcare investment market 2 Total

  5. Slide 5: Investment Highlights

    Investment Highlights The only biomimetic balloon expandable TAVR with >130 treated patients Poised to disrupt a high value, growth Path to Commercialization market Proprietary, Multi-billion-dollar Clinical Commercial Commercial First-in-Class TAVR global TAVR market Validation Readiness Launch >13

  6. Slide 6: Global Manufacturing Footprint

    Global Manufacturing Footprint Purpose-built infrastructure designed for efficient scale-up and commercial readiness 6

  7. Slide 7: TAVR market opportunity expected to reach US$9.9bn in 2028

    TAVR market opportunity expected to reach US$9.9bn in 2028 Underpenetrated patient population with only 15-20%1 of severe aortic stenosis cases treated today TAVR Aortic Stenosis & Valve-in-Valve Market2 Potential for further significant growth 14.0 Industry trials in progress 12.0 12.4 Severe Aorti

  8. Slide 8: A New Class of TAVR

    A New Class of TAVR anteristech.com

  9. Slide 9: Aortic Stenosis (AS) - Current Treatment Options

    Aortic Stenosis (AS) - Current Treatment Options SAVR – Invasive, open-heart surgery A life-threatening condition caused by narrowing of the aortic valve Patients with severe AS have a 50% risk of dying within 2 Years1 TAVR - Minimally invasive procedure 1. Leon M B, Smith CR, M ack M, e t al. Tra n

  10. Slide 10: Yesterday's TAVRs were not developed for today's patients

    Yesterday’s TAVRs were not developed for today’s patients DurAVR® was deliberately designed for younger and more active patients Patients need a safer alternative to Patients need a valve that restores an active open heart surgery lifestyle for the rest of their life First & second Third generation

  11. Slide 11: Anteris set out to address the needs in TAVR by asking different questions

    Anteris set out to address the needs in TAVR by asking different questions How does a healthy How can we mimic a How can we put that How do we deliver aortic valve perform? native valve? valve in a frame? the valve? Our expert panel of physicians advised the Company what they wanted in a next genera

  12. Slide 12: DurAVR®: A New Class of TAVR

    DurAVR®: A New Class of TAVR Single-piece, native-shaped biomimetic design built to mimic the performance of a healthy aortic valve. 12

  13. Slide 13: Sustained 1-year DurAVR® hemodynamic performance

    Sustained 1-year DurAVR® hemodynamic performance Mean Annular Diameter: 22.7 mm MPG (Mean Pressure Gradient mmHg) 8.6 EOA (Effective Orifice Area cm2) 2.1 DVI (Doppler Velocity Index) 0.58 Mean Pressure Gradient (MPG) • The average pressure across the aortic valve between the left ventricle and aort

  14. Slide 14: Clinician quote: balloon expandable valve with self-expanding hemodynamics

    “ A balloon expandable valve with self-expanding hemodynamics is like the “ holy grail. Dr Michael Reardon Professor of Cardiothoracic Surgery, Allison Family Distinguished Chair of Cardiovascular Research Methodist DeBakey Heart & Vascular Center Clinician panel discussion, PCR London Valves 2023.

  15. Slide 15: Restores flow dynamics, significantly reducing left ventricular (LV) mass

    Restores flow dynamics, significantly reducing left ventricular (LV) mass SEVERE AORTIC STENOSIS Increased LV mass is an adaptive response to the increased workload caused by the narrowed aortic valve. Untreated it may progress to heart failure. A narrowed aortic valve creates increased pressure in

  16. Slide 16: DurAVR® is the first aortic valve to restore normal aortic flow

    DurAVR® is the first aortic valve to restore normal aortic flow Normal Aortic Flow Impaired Aortic Flow When compared to a healthy aortic valve, DurAVR® THV Normal Valve (n=5) vs: TAVR (n=4) p<0.05 | SAVR (n=8) p<0.01 showed no significant difference in flow (p>0.05) Healthy Aortic Valve Severe AS S

  17. Slide 17: Valve in Valve (ViV) expanding TAVR market

    Valve in Valve (ViV) expanding TAVR market – US$2.5bn by 2028 Existing bioprosthetic valves fail and patients need retreatment ViV Challenges Preserving coronary access, providing good hemodynamic result Solution – DurAVR® THV Short-frame valve, paradigm-shifting hemodynamic performance and large op

  18. Slide 18: Path to Commercialization

    Path to Commercialization anteristech.com

  19. Slide 19: 130 DurAVR® patients – support pivotal trial launch (PARADIGM Trial)

    130 DurAVR® patients – support pivotal trial launch (PARADIGM Trial) 2021 2022 2023 2024 2025 First-in-human (“Embark”) Study FPI Nov 2021 FDA submission Early Feasibility Study (“EFS”) - DurAVR® Ongoing monitoring FDA approval Valve-in-Valve Compassionate use Patient recruitment commenced 4Q 2025 L

  20. Slide 20: PARADIGM Trial

    PARADIGM TRIAL

  21. Slide 21: The first all-risk, head-to-head TAVR registration trial

    The first all-risk, head-to-head TAVR registration trial “All Comers” Randomized Cohort 1-year data used to support PMA Submission Assessment for Eligibility Enrollment I Study Co-Chairs: Dr. Michael J. Reardon, Professor Stephan Windecker 1:1 Randomization (All surgical risk strata) Clinical Trial

  22. Slide 22: PARADIGM Trial – Planned enrollment and anticipated revenue

    PARADIGM Trial – Planned enrollment and anticipated revenue * Category B Medicare coverage of US$25k per device* ENROLLMENT FOLLOW UP REVIEW Patients screened for eligibility. Patients followed up at 1 month, The 1-year data is included in a PMA If selected, they are randomized and 1 year (primary s

  23. Slide 23: Low Risk Randomized Continued Access Cohort and ViV Registry Cohort

    Low Risk Randomized Continued Access Cohort and ViV Registry Cohort Low Risk Randomized Continued Access Cohort Valve-in-Valve Cohort Commences when ‘all-risk’ PMA study recruitment concludes Standalone parallel registry Enrollment II Assessment for Eligibility Enrollment Assessment for Eligibility:

  24. Slide 24: Anticipated Milestones

    Anticipated Milestones Q4 2024 (completed) Q2 2025 (completed) Q4 2025 (completed) Q2 2026 Q4 2026 • Danish regulatory clearance for • US IPO & NASDAQ LISTING • PARADIGM - EU Investigator Meeting • PCR presentation • PARADIGM PARADIGM Trial • TCT presentation: Flow • PCR – Innovation session Trial L

  25. Slide 25: Key Takeaways

    Key Takeaways Building commercial readiness for a new class of TAVR that mimics a healthy aortic valve 1 DurAVR® THV - Proprietary, new class of TAVR for aortic stenosis - Easy, predictable balloon expandable deployment with the function of a healthy, native aortic valve 2 US$9.9bn global TAVR marke

  26. Slide 26: Appendices

    Appendices

  27. Slide 27: Procedural Success Endpoints Across Various Anatomies

    Procedural Success Endpoints Across Various Anatomies Technical Success (VARC 3): 94% Challenging anatomies treated Device Success (VARC 3): 92.3% (Baseline MDCT) n = 65 Severe annular calcium Extreme leaflet calcium Type 1 bicuspid Extreme LVOT calcium 1 patient required 2 valves; 3 patients had va

  28. Slide 28: DurAVR® Data Spotlight in Small Annulus Patients

    DurAVR® Data Spotlight in Small Annulus Patients 97% freedom from moderate or No Moderate or Severe Paravalvular Leak severe prosthesis-patient mismatch1 1. De Ba ck er, O. Outcom es of a Novel Biomi metic Balloon Expandable Valve in Small A ortic A nnuli. Oral Presentation at: PC R Londo n Valves;

  29. Slide 29: Medical Advisory Board

    Medical Advisory Board Anteris is guided by a global team of well-regarded cardiovascular physician advisors North America Europe Australia 29

  30. Slide 30: Highly Experienced Leadership – Clinical, Operational, Commercial

    Highly Experienced Leadership – Clinical, Operational, Commercial Wayne Paterson David St Denis Matthew McDonnell Dr. Chris Meduri VICE CHAIRMAN & CEO PRESIDENT & DIRECTOR CHIEF FINANCIAL OFFICER CHIEF MEDICAL OFFICER Mr. Paterson has served as CEO since March 2017 and was appointed Vice Mr. St Deni

  31. Slide 31: Board of Directors

    Board of Directors John Seaberg Wayne Paterson Dave Roberts Greg Moss David St Denis CHAIRMAN VICE CHAIRMAN & CEO NON-EXECUTIVE DIRECTOR NON-EXECUTIVE DIRECTOR PRESIDENT & DIRECTOR Mr. Seaberg has been Chairman Mr. Paterson has served as CEO since Mr. Roberts joined LeMaitre Mr. Moss serves as Chief