Actelis Networks, Inc. · OTC:ASNS

Actelis Networks — Technical Presentation (September 2019)

46 slides from Actelis Networks's technical presentation, September 2019

  1. Slide 1: Actelis Training Series: Repeaters Made Easy

    High Performance Broadband Over Copper Actelis Training Series Repeaters Made Easy XR239 Training - Getting the most from your Actelis’ Repeatered High Speed Links Frank W Alexander III Director of Sales Engineering and Field Support Email: FAlexander@Actelis.com Office: +1 585 612 0288; Cell: +1 51

  2. Slide 2: History of Innovation in Copper Technologies

    History of Innovation in Copper Technologies • BBA 3.0 - VBA • BBA– GBA, SBA • ML690E/ES • ML690EN • ML700 CE 2.0 • ML650xx: TDM & Enhanc. Eth. • ML640E product line • ML540E CE 2.0 NID • ML684DRTP • Symmetrical Vectoring: • Introducing SDN • ML620R 1/2/4 pairs • ML5x0M/S - Unprecedented Rate & CE2.

  3. Slide 3: Long Reach, Fiber Quality Services for Hybrid Fiber-Copper Networks

    Long Reach, Fiber Quality Services for Hybrid Fiber - Copper Networks Ethernet Access Devices Ethernet Aggregation (EAD/EDDs) Switches  Deliver 100’s of Mbps over existing copper pairs  Optimized for different network topologies and >1G over fiber/ G.fast and CO sizes  G.FAST, VDSL, G.SHDSL  Poi

  4. Slide 4: Delivering Fiber-Grade Services Instantly over Bonded Copper

    Delivering Fiber-Grade Services Instantly over Bonded Copper (up to 10Gbps and up to 100Km) Business Ethernet Smart City Services ML600 ERPS G.8032 ML2300 RING Community (Police/Fire/ Education /Medical) Branch Office / SME Utility, Bandwidth To the Building Industry Factory DSLAM Cabinet SOHO ITS V

  5. Slide 5: Actelis' XR239SE Repeaters

    Actelis’ XR239SE Repeaters High Speed • Allows same rate at longer distances or higher rate at same distance High Reliability • 239 Mechanics – fits in standard repeater housings • Powered by PFU – injects DC voltage along Compact with Data pairs for Repeater powering • Each Repeater handles 2 pairs

  6. Slide 6: Actelis' PFU-8x

    Actelis’ PFU-8x • Remote Power Feeding Unit - 8 pair unit • Up to 8 repeater hops per link in dual-side feeding mode (4 with PFU-8E) Long Reach • Enables high BW over very long reach with multi hop repeaters – Up to tens of Kilometers/Miles • Easy configuration through Dip-switches High • Supports b

  7. Slide 7: HSL Repeater Spacing – Maximize Link Bandwidth

    HSL Design and Installation HSL Repeater Spacing – Maximize Link Bandwidth • Unlike T-1 and HDSL, there is no required spacing • Proper spacing determined by BW goal • Shorter sections = Higher BW Longer section = Lower BW • Total HSL BW dependent on longest section Example – Impact of • For best re

  8. Slide 8: Broadband Rate & Reach Calculator – Friendly Planning

    HSL Design and Installation Broadband Rate & Reach Calculator – Friendly Planning Available @ Actelis.com 1. Set Region and Units 2. Set Equipment (CP/CPE) 3. Set # Repeaters (Hops/Segments) 4. Set Gap 5. Set SNR 6. Enter Loop Lengths (separately per each hop with repeaters) 7. Click Calculate 8. Op

  9. Slide 9: HSL Power Feeding – Single Fed

    HSL Design and Installation HSL Power Feeding – Single Fed • Each PFU Port can support up to 4 repeaters • A PFU-8x unit can support up to 16 repeaters – 8 lines x 4 repeaters (2 pair) per line • Even number of pairs only in a repeatered HSL • All repeaters must be fed by two pairs Page 9 Confidenti

  10. Slide 10: HSL Power Feeding – Dual Fed

    HSL Design and Installation HSL Power Feeding – Dual Fed • Each PFU Port can support up to 4 repeaters per line, two PFUs needed for more than 4 Repeaters, up to 8 repeaters per line • Repeatered HSL should always be configured with an even number of pairs • All repeaters must be fed by two pairs Pa

  11. Slide 11: Repeater Duos

    HSL Design and Installation Repeater Duos • Duos are the two pairs that share the repeater slot • Duos must remain together across all repeaters In this example: • Pairs 1 and 2 are Duos • Pairs 3 and 4 are Duos • Etc… Page 11 Confidential to Actelis Networks - Copyright ©2019 ALL RIGHTS RESERVED

  12. Slide 12: PFU Setup

    HSL Design and Installation PFU Setup D Configure Dip-Switches Page 12 Confidential to Actelis Networks - Copyright ©2019 ALL RIGHTS RESERVED

  13. Slide 13: PFU Setup (continue)

    HSL Design and Installation PFU Setup (continue) • Cards & Modules -> PFUs • Select appropriate PFU • Configure -> Enable • Select the Ports Details button • In the Ports Details screen, select the ports desired and click Turn On Power Page 13 Confidential to Actelis Networks - Copyright ©2019 ALL R

  14. Slide 14: Repeater Setup – Single Fed

    HSL Design and Installation Repeater Setup – Single Fed Through DS =Dip Switch 8 pairs Page 14 Confidential to Actelis Networks - Copyright ©2019 ALL RIGHTS RESERVED

  15. Slide 15: Repeater Setup – Dual Fed

    HSL Design and Installation Repeater Setup – Dual Fed Actelis XR239SE does not require pair swapping to support feeding from CPE side. Older Actelis repeaters such as P/N 501R20086 would. Page 15 Confidential to Actelis Networks - Copyright ©2019 ALL RIGHTS RESERVED

  16. Slide 16: Repeater Housings

    HSL Design and Installation Repeater Housings • Standard 239 Mechanics • Same Thermal characteristics as HDSL repeaters • No need to skip slots in HDSL Rated Housings • No need to rewire existing T1/HDSL Housings Page 16 Confidential to Actelis Networks - Copyright ©2019 ALL RIGHTS RESERVED

  17. Slide 17: Configure HSL

    HSL Provisioning Configure HSL • Select the appropriate HSL in the Command Tree • Click Configure on HSL Pane Page 17 Confidential to Actelis Networks - Copyright ©2019 ALL RIGHTS RESERVED

  18. Slide 18: HSL Configuration Screen

    HSL Provisioning HSL Configuration Screen • Enable • Mode – Office or Remote • HSL ID • Topology – # of Repeaters No Repeaters 1–4 Rep. Hops >4 Hops – set to 4 • LOWBW Threshold • LLCF Threshold • Quarantine • Scheduled/Unscheduled BW Restoration • Optional Description Page 18 Confidential to Acteli

  19. Slide 19: Add Modem Ports to HSL

    HSL Provisioning Add Modem Ports to HSL • Enable • Circuit ID • HSL • Max Allowed Rate • LOWSNRM Threshold • HIATTN Threshold • MLP Duo • Powering: PFU and Port Page 19 Confidential to Actelis Networks - Copyright ©2019 ALL RIGHTS RESERVED

  20. Slide 20: Evaluating the Uncalibrated HSL

    Evaluating the Uncalibrated HSL • Select HSL in Command Tree • Note HSLDIAG Alarm • Click Topology Page 22 Confidential to Actelis Networks - Copyright ©2019 ALL RIGHTS RESERVED

  21. Slide 21: Topology Screen – Line Performance

    Evaluating the Uncalibrated HSL Topology Screen – Line Performance • CO Port • ATTN • Compare Values from Pair to Pair • Rate • ERR • Outliers are usually bad • PFU Status • EWL • Significantly different SNRs at each end of • PFU Port • PBO the same piece of wire usually indicate noise (or bad repea

  22. Slide 22: Topology Screen – Line Inventory

    Evaluating the Uncalibrated HSL Topology Screen – Line Inventory • Verify Repeater S/Ns align with Repeater Duos Page 24 Confidential to Actelis Networks - Copyright ©2019 ALL RIGHTS RESERVED

  23. Slide 23: Topology Screen – Power Status

    Evaluating the Uncalibrated HSL Topology Screen – Power Status • Verify Repeater DS Settings and Actual PWR Mode Page 25 Confidential to Actelis Networks - Copyright ©2019 ALL RIGHTS RESERVED

  24. Slide 24: HSL Calibration

    HSL Calibration • Select HSL in Command Tree • Click Calibrate Page 26 Confidential to Actelis Networks - Copyright ©2019 ALL RIGHTS RESERVED

  25. Slide 25: HSL Calibration Screen

    HSL Calibration Calibration Screen • Bandwidth/Rate • Dynamic Rate Boost • SNR Margin Spectral Targets • Regulations – NA1 – No Limit – Best Performance • Voluntary DSS Moderate High Highest Page 27 Confidential to Actelis Networks - Copyright ©2019 ALL RIGHTS RESERVED

  26. Slide 26: Actelis Dynamic Spectral Shaping - Voluntary DSS

    Actelis Dynamic Spectral Shaping - Voluntary DSS • Applies Power Back-Off (PBO) per available excess PBO Level Max PBO Link SNR for enhanced binder friendliness (Max) (dB) Robustness * • The performance optimization is completely automatic Moderate up to 11dB Highest • Performed per segment, not per

  27. Slide 27: HSL Trouble Shooting

    HSL Trouble Shooting Some points to remember: • Unlike HDSL, our system does not sync up from end to end but rather each section syncs up independently • Each pair is independent and bidirectional • More closely related to ADSL than HDSL • The HSL is a dynamic system that changes from moment to mome

  28. Slide 28: How an HSL works - Calibration

    HSL Trouble Shooting How an HSL works - Calibration • Based on Trial and Error • The System guesses at the next rate to try based on current Rate and SNR • Attempts to achieve the maximum BW and still maintain the target SNR set on the calibration screen • Intermittent anomalies will confuse this pr

  29. Slide 29: How an HSL works - Recovery

    HSL Trouble Shooting How an HSL works - Recovery • On Recovery, the pairs initially sync up at a low, fail safe rate to verify the far end is reachable, either 960K or 1920K • Once all pairs have connected to the far end, the HSL drops and the pairs attempt to recover at the calibrated (or adjusted)

  30. Slide 30: How an HSL works - Rate Adaption

    HSL Trouble Shooting How an HSL works - Rate Adaption • Impairments on a pair will cause it to drop and recover • The system lowers the Rate attempting to deal with the impairment • Handles long term impairments • BW restoration – forced or scheduled Page 32 Confidential to Actelis Networks - Copyri

  31. Slide 31: How an HSL works - Qualification Failed

    HSL Trouble Shooting How an HSL works - Qualification Failed • When a pair fails to calibrate for whatever reason, it goes into a “Qual. Failed” state • In this state it is no longer trying to sync with the far end • You could make this pair the best pair ever, it will still not sync when in this st

  32. Slide 32: How an HSL works - Dynamic Addition

    HSL Trouble Shooting How an HSL works - Dynamic Addition • Designed to add pairs to an existing Calibrated HSL • Only one pair at a time • Calibrates single pair in already calibrated HSL without being service affecting • Disable Modem Port from Configuration screen to remove from HSL • Re-enable Mo

  33. Slide 33: Topology Test

    HSL Trouble Shooting - Topology Test • Accessed from HSL screen • Tests two pairs at a time • Pairs under test must be Duos • Allows you to single step sync process from Repeater to Repeater • Pair must be suspended • Check pairs to be tested and click Start • System will advance to next repeater an

  34. Slide 34: Applying Modem Tone

    HSL Trouble Shooting Applying Modem Tone Applies Tone to Modem Port • Select Modem Port to be tested in Command Tree • Suspend Modem • Select Operate Tone • Regular or Distinct (SDU Only) Page 36 Confidential to Actelis Networks - Copyright ©2019 ALL RIGHTS RESERVED

  35. Slide 35: TDR

    HSL Trouble Shooting TDR Time Domain Reflectometry • Select Modem Port to be tested in Command Tree • Suspend Modem • Select TDR Page 37 Confidential to Actelis Networks - Copyright ©2019 ALL RIGHTS RESERVED

  36. Slide 36: TDR (continued)

    HSL Trouble Shooting TDR (continued) • Start Location • Measurement Units • Cable Type • Start Test Page 38 Confidential to Actelis Networks - Copyright ©2019 ALL RIGHTS RESERVED

  37. Slide 37: TDR Results - Normal

    HSL Trouble Shooting TDR Results - Normal • Normal cable section with no impairments • Repeater at ≈ 5 Kft • Each dot on the results graph represents 100’ Page 39 Confidential to Actelis Networks - Copyright ©2019 ALL RIGHTS RESERVED

  38. Slide 38: TDR Results - Open

    HSL Trouble Shooting TDR Results - Open • Open cable • Open at ≈ 4.5 Kft • Each dot on the results graph represents 100’ Page 40 Confidential to Actelis Networks - Copyright ©2019 ALL RIGHTS RESERVED

  39. Slide 39: TDR Results - Short

    HSL Trouble Shooting TDR Results - Short • Shorted cable • Short at ≈ 4.5 Kft • Each dot on the results graph represents 100’ Page 41 Confidential to Actelis Networks - Copyright ©2019 ALL RIGHTS RESERVED

  40. Slide 40: PFU

    HSL Trouble Shooting PFU • Cards & Modules -> PFUs • State • Card Status • Inventory Info populated • Alarms and Conditions • Port Details Button Page 42 Confidential to Actelis Networks - Copyright ©2019 ALL RIGHTS RESERVED

  41. Slide 41: PFU Ports Details

    HSL Trouble Shooting PFU Ports Details • Port ID • Status • PWR Status • PWR Request • PWR By DS • Current Fault • Last Fault • Last Fault Time • Select one or multiple ports to turn on or off Page 43 Confidential to Actelis Networks - Copyright ©2019 ALL RIGHTS RESERVED

  42. Slide 42: PFU Voltage and Current – PFU Data from TL-1 Log

    HSL Trouble Shooting PFU Voltage and Current – PFU Data from TL-1 Log • Curr: Port current in ma • VOP: Tip Voltage • VON: Ring Voltage • VO: Tip-Ring Voltage • UNB: Imbalance Ratio • FLT: Current Fault • LASTFLT: Last Fault • LFDATE: Last Fault Date • LFTIME: Last Fault Time "PFU-1-1: CURR=29.50, V

  43. Slide 43: Alarm History

    HSL Trouble Shooting Alarm History • System Administration -> Alarms • Last 512 Events • Time stamp depends on accurate system time • Time • Severity • Condition Type • AID • SA/NSA • Desc • Location • Direction Page 45 Confidential to Actelis Networks - Copyright ©2019 ALL RIGHTS RESERVED

  44. Slide 44: Modem Quarantine

    HSL Trouble Shooting Modem Quarantine • Errors on a single pair will corrupt traffic across the whole HSL • Quarantine must be enabled on HSL • In Quarantine condition - Pair stays up but system stops sending traffic across it • Asserts after 3 ES or 1 SES • Recovers after 60 seconds error free • Ha

  45. Slide 45: Q&A

    Q&A • Raise your hand or use the chat function to ask any questions you may have! • Actelis Support: 866-638-2544 • Or chat at Actelis.com • All our documentation, training slides, and a host of other helpful materials are available at Actelis.com. Sign up today! • You will be receiving a follow up

  46. Slide 46: Thank You!

    Thank You! Page 49 Confidential to Actelis Networks - Copyright ©2019 ALL RIGHTS RESERVED

Actelis Networks — Technical Presentation (September 2019) on 6ix