Uniper Se · XETR:UN0

Uniper — Corporate Update (April 2022)

8 slides from Uniper's corporate update, April 2022

  1. Slide 1: Power Plant Group West 1 - Scholven

    Power Plant Group West 1 - Scholven Status date: 28.11.2017

  2. Slide 2: A long tradition of energy generation: Scholven since 1908

    A long tradition of energy generation Scholven since 1908 Sinking of the Increasing the output to 160 MW and supply Post World War II coal mine pit of the nearby chemical industry reconstruction is largely Scholven with power and steam completed July 1908 until 1930 1948-1951 1912 1944/1945 A 240 KW

  3. Slide 3: Scholven – site history

    Scholven – site history Commissioning of units B-E Commissioning of units New district heating unit Buer (138 MWeq) (4 x 345 MW = 1.380 MW coal) G+H (2 x 714 MW oil) (installed capacity in total now 3,622 MW) 1968-1971 1974/1975 1985 1970 1979 Hibernia AG changes to Commissioning of unit F VEBA Kraf

  4. Slide 4: Scholven – site history

    Scholven – site history VEBA Kraftwerke Ruhr AG Complete dismantling of Installed capacity: 828 MW, production of steam becomes PreussenElektra, units G and H and compressed air to surrounding industry later E.ON 1998-2000 2010 from 01.01.2015 2001/2003 31.12.2014 2016 Shutdown of units G and H Shut

  5. Slide 5: Power Plant Group West today

    Power Plant Group West 1 today Heating plant Westerholt Heating plant Marl Scholven power plant Heating plant Recklinghausen District heating exchanger Schlägel & Eisen Steam plant Zweckel

  6. Slide 6: Large interconnected district heating network

    Scholven supplies a large interconnected district heating network… Heating plant Heating plant (auxiliary/peak) (stillgelegt) Mine gas CHP External heat source under contract Interconnected district heating network Directly supplied areas Areas supplied by sales partners Distance East to West 28.4 k

  7. Slide 7: Scholven makes the most out of coal: cogeneration of heat and power

    Scholven makes the most out of coal: cost effective and environmental friendly cogeneration of heat and power Cogeneration Heat/Power +13% using CHP Electrical generation only 0 10 20 30 40 50 60 70 80 90 100 Used for electrical generation Used for heat generation Cooling loss Flue gas loss Own usag

  8. Slide 8: Functional diagram of a coal fired power plant

    Functional diagram of a coal fired power plant Transformer Reheater Turbine DENOX/ SCR Generator FGD ESP Steam generator Buer CHP unit has neither condenser nor cooling tower: Cooling cycle The condensing heat is fed directly into the district heating system.

Uniper — Corporate Update (April 2022) on 6ix