GMW116 main features Features: Two 0 ...10 V analog outputs: CO2 and T Measurement ranges: CO2: 0...2000 ppm T: 0...+50°C Accuracy: CO2: ±(2% of range + 2% of reading) T: ±0.7°C at 25°C Long-term stability (CO2): ±5% of range/5 years Housing: ABS material, UL-V0 fire rating IP3
Slide 4: GMW 116: Order form
GMW 116: Order form 1 2 3 4 5 Vaisala Carbocap® CO2 and T transmitter GMW116 C 1 V 0 PRICE 1 CO2 range 0 ... 2000 ppm C 2 Temperature output range 0°C ...+50°C 1 4 Accessories None 0 5 Quick reference guide None 0 English E TOTAL QTY TOTAL VALUE Selections in bold are included in the prices of the b
Product comparison Temperature Calibration Field Exchangeable Operating Product Display Relay Analog Outputs Digital outputs IP class measurement ranges measurement certificate adjustment probe range GMT220 optional 2 0...10V,0/4...20mA - IP65 2000 ppm up to 20% - + With GM70 + -20 ... +60°C GMW21&2
Slide 7: Advantages of the GMW116 and CARBOCAP technology
Advantages of the GMW116 and CARBOCAP® technology Works perfectly also in spaces with round-the-clock occupancy. Excellent long term stability for best savings through demand controlled ventillation Internal compensation of ideal gas thermal expansion for correct PPM values over the temperatur
Slide 8: Proven track record: Stability test results for GMW115
Proven track record: Stability test results for GMW115 GMW115 stability test Test moved to new 550 y = -0.0058x + 611.2 Stability graphs showing y = -0.0362x + 1803.8 y = -0.0189x + 1134.5 measurment of 500 y = -0.0394x + 1959.1 background concentration with 4 GMW115:s Total time 3.6 years 450 G