VolitionRx Limited · AMEX:VNRX

VolitionRx — Technical Presentation (May 2022)

6 slides from VolitionRx's technical presentation, May 2022

  1. Slide 1: Circulating Nucleosomes for Detection of Colorectal Cancer and High-risk Advanced Adenomas

    Slide 1: Circulating Nucleosomes for Detection of Colorectal Cancer and High-risk Advanced Adenomas

    Circulating Nucleosomes for Detection of Colorectal Cancer and High-risk Advanced Adenomas Li-Chun CHANG1, Marielle HERZOG2, Nathalie HARDAT2, Dorian PAMART2, Han-Mo CHIU1 1Department of Internal Medicine, National Taiwan University Hospital, Taipei 10002, Taiwan. 2Belgian Volition SRL, 22 Rue Phoca

  2. Slide 2: Background and aim

    Slide 2: Background and aim

    Background and aim • Approximately 60% of Fecal immunochemical tests (FITs) are false-positive and result in a lot of unnecessary colonoscopies. • There is an unmet need for a simple test to supplement FIT to triage individuals at higher risk who require colonoscopy referrals. • FIT is less effectiv

  3. Slide 3: Material and Methods

    Slide 3: Material and Methods

    Material and Methods • 520 average-risk asymptomatic patients: (i) CRC (n= 33), (ii) advanced adenoma (AA) (n=123, including 18 with AA>2cm); (iii) non-AA (n=168); (iv) non-neoplastic polyps (n=30); (vi) colonoscopy negative control (n=166). • Plasma and stool samples were obtained prior to colonosc

  4. Slide 4: Results

    Slide 4: Results

    Results Nu.Q® biomarkers (H3K27Me3 and H3R8Cit) plus FIT improved sensitivity for CRC and AA Combination of two Nu.Q® biomarkers H3K27Me3 and H3R8Cit with FIT allowed: • The detection of all CRC and 94.3% of AA, including all the high-risk adenomas. • The detection of 50/55 proximal adenomas includi

  5. Slide 5: Results

    Slide 5: Results

    Results Nu.Q® biomarkers: H3K27Me3 and H3R8Cit plus FIT could reduce unnecessary colonoscopies • The same combination Control Non-neoplastic polyps could reduce unnecessary colonoscopies by 21.8% 21.8% 23.3% and 23.3% in control and Nu.Q® biomarkers + FIT non-neoplastic polyps 78.2% 76.7% subgroups

  6. Slide 6: Conclusion

    Slide 6: Conclusion

    Conclusion • H3K27Me3 and H3R8Cit-nucleosome levels in combination with FIT in a logistic regression model could: ✓Improve the detection of proximal high-risk AA ✓Provide a non-invasive method to reduce unnecessary colonoscopy • Combination use of a nucleosome blood test with FIT may improve the eff