  1. Slide 1: Power Line Electrical Safety

    Power Line Electrical Safety Engr. Efren Domingo Safety, Occupational Health and Environment Management

  2. Slide 2: Power Line Electrical Safety

    POWER LINE ELECTRICAL SAFETY Engr. Efren V. Domingo Head - Safety, Occ. Health & Environment Management

  3. Slide 3: Outline

    Outline •Public Safety Statistics •Causes & Analysis •Power Line Designs •Elec. Shocks – How it can harm? •Effects to Human Body •Contacts to avoid •Preventive Measures •Meralco Public Safety Initiatives

  4. Slide 4: Majority of public incidents are building work site related

    MAJORITY OF PUBLIC INCIDENTS ARE BUILDING WORK SITE (BWS) RELATED Summary of Public Incident Per Type (2012-2016) Natural Phenomenon, Kite Flying, 23, 1% 37, 2% Tree Trimming/ Fruit Picking, 106, 6% Other Random Contacts to Power Lines, 371, 20% BWS Activities, 1153, 62% Antenna Installation, 161, 9

  5. Slide 5: Why do BWS public incidents occur?

    WHY DO BWS PUBLIC INCIDENTS OCCUR ? Population increase in the franchise area Continuous development and industry boom Lack of Safety awareness

  6. Slide 6: Voltage increases as the height increases

    VOLTAGE INCREASES AS THE HEIGHT INCREASES 115, 000 Volts 34, 500 Volts

  7. Slide 7: Distribution lines are equally dangerous as transmission lines

    DISTRIBUTION LINES ARE EQUALLY DANGEROUS AS TRANSMISSION LINES 34, 500 Volts 230 Volts

  8. Slide 8: Slide 8

  9. Slide 9: Slide 9

  10. Slide 10: Shock is a product of live line and a grounded body contact

    SHOCK IS A PRODUCT OF LIVE LINE & A GROUNDED BODY CONTACT Distribution Substation Transformer Secondary / Overhead Lines Service Lines 230V 20,000V Neutral Line Ground Ground Earth ground

  11. Slide 11: Electrical current can be fatal when it passes through the heart

    ELECTRICAL CURRENT CAN BE FATAL WHEN IT PASSES THROUGH THE HEART Jewelries are strong conductors, avoid wearing it in worksites

  12. Slide 12: How electricity can harm you?

    HOW ELECTRICITY CAN HARM YOU? Organ burns: 5000- 6000 Heart paralysis: 250- 300 Ventricular fibrilation: 75-100 Respiratory paralysis: 30-75 "Let go" threshold: 10- 40 Pain 3-10 Muscle contraction: 1-5 Perception: 0.5-1.5 0.1 1 10 100 1000 10000 Milliamperes 1 Amp 10 Amp

  13. Slide 13: How electricity can harm you? Ohm's Law

    HOW ELECTRICITY CAN HARM YOU? OHM’s Law V = IR or I = V R Where: V - potential in VOLTS I - current in AMPERES R - resistance in OHMS

  14. Slide 14: How electricity can harm you? Sample computation

    HOW ELECTRICITY CAN HARM YOU? Sample Computation Under dry conditions, the resistance offered by the human body may be as high as 100,000 Ohms. Wet or broken skin may drop the body's resistance to 1,000 Ohms.

  15. Slide 15: How electricity can harm you? Sample computation

    HOW ELECTRICITY CAN HARM YOU? Sample Computation I= V Where R =2000 ohms (Resistance of human body) R 12 Volts I = 12 Volts / 2000 Ohms car battery 40 Amperes I = 0.006 Ampere

  16. Slide 16: How electricity can harm you? Battery

    HOW ELECTRICITY CAN HARM YOU? Organ burns: 5000- 6000 Heart paralysis: 250- 300 Ventricular fibrilation: 75-100 Respiratory paralysis: 30-75 BATTERY "Let go" threshold: 10- 40 Pain 3-10 Muscle contraction: 1-5 Perception: 0.5-1.5 Milliamperes 0.1 1 10 100 1000 10000 1 Amp 10 Amp

  17. Slide 17: How electricity can harm you? Sample computation

    HOW ELECTRICITY CAN HARM YOU? Sample Computation I= V Where R =2000 ohms (Resistance of human body) R 110 Volts I = 110 Volts / 2000 Ohms line-to-ground 15 Amperes I = 0.055 Amperes

  18. Slide 18: How electricity can harm you? Outlet

    HOW ELECTRICITY CAN HARM YOU? 220 OUTLET Organ burns: 5000- 6000 Heart paralysis: 250- 300 110 OUTLET Ventricular fibrilation: 75-100 Respiratory paralysis: 30-75 BATTERY "Let go" threshold: 10- 40 Pain 3-10 Muscle contraction: 1-5 Perception: 0.5-1.5 Milliamperes 0.1 1 10 100 1000 10000 1 Amp 10 Am

  19. Slide 19: Effects of electrical contact to the human body

    EFFECTS OF ELECTRICAL CONTACT TO THE HUMAN BODY

  20. Slide 20: Possible outcomes after becoming in contact with power lines

    POSSIBLE OUTCOMES AFTER BECOMING IN CONTACT WITH POWER LINES Fall from height Unconciousness or head injury from falls

  21. Slide 21: Severe skin burns result from electricity flowing in the body

    SEVERE SKIN BURNS RESULT FROM ELECTRICITY FLOWING IN THE BODY

  22. Slide 22: Electrical current enters and exits from extremities

    ELECTRICAL CURRENT ENTERS AND EXITS FROM EXTREMITIES

  23. Slide 23: Electrical contact can be fatal

    ELECTRICAL CONTACT CAN BE FATAL

  24. Slide 24: Contacts that must be avoided

    CONTACTS THAT MUST BE AVOIDED

  25. Slide 25: Antenna Installation

    Antenna Installation Entry point

  26. Slide 26: Tree Trimming/Pruning

    Tree Trimming/Pruning

  27. Slide 27: Fruit Picking

    Fruit Picking

  28. Slide 28: Kite Flying

    Kite Flying

  29. Slide 29: Contacts that must be avoided: construction activities

    CONTACTS THAT MUST BE AVOIDED CONSTRUCTION ACTIVITIES

  30. Slide 30: Working near powerlines must be avoided

    WORKING NEAR POWERLINES MUST BE AVOIDED

  31. Slide 31: Improper handling of items are common accident causes

    IMPROPER HANDLING OF ITEMS ARE COMMON ACCIDENT CAUSES

  32. Slide 32: All construction materials are conductors of electricity

    ALL CONSTRUCTION MATERIALS ARE CONDUCTORS OF ELECTRICITY

  33. Slide 33: All construction materials are conductors of electricity

    ALL CONSTRUCTION MATERIALS ARE CONDUCTORS OF ELECTRICITY

  34. Slide 34: Be mindful of long items that may bring contact to powerlines

    BE MINDFUL OF LONG ITEMS THAT MAY BRING CONTACT TO POWERLINES

  35. Slide 35: Spotters are necessary to guide crane operators

    SPOTTERS ARE NECESSARY TO GUIDE CRANE OPERATORS AVOID POWERLINE CONTACT

  36. Slide 36: Concrete pumps are exposed to the same hazards as cranes

    CONCRETE PUMPS ARE EXPOSED TO THE SAME HAZARDS AS CRANES

  37. Slide 37: Measures to avoid contact: construction activities

    MEASURES TO AVOID CONTACT CONSTRUCTION ACTIVITIES

  38. Slide 38: Maintain a minimum safe distance of 3 meters

    AVOID POWERLINE CONTACT, MAINTAIN A MINIMUM SAFE DISTANCE OF 3-METERS

  39. Slide 39: Before construction coordination should be made with Meralco

    BEFORE CONSTRUCTION COORDINATION SHOULD BE MADE WITH MERALCO

  40. Slide 40: Safe clearances required by law

    SAFE CLEARANCES REQUIRED BY LAW *Based from 2009 Philippine Electrical Code Part 1 Volume 1

  41. Slide 41: Meralco Public Safety Initiatives

    MERALCO PUBLIC SAFETY INITIATIVES

  42. Slide 42: Reconstruction of Facilities/Engineering Methods

    Reconstruction of Facilities/Engineering Methods Installation of conductor covers to provide barrier to construction workers. Reconstruction of facilities to Installation of insulated wires to line maintain safe clearance from facilities to avoid accidental contact. building under construction.

  43. Slide 43: Ground Work Activities

    Ground Work Activities Flip Chart Cover Page Content in Filipino for easy comprehension Electrical safety lectures at Roxas High School, Quezon City Building work site safety lectures were conducted using Flip Charts Council of Student Chapters Forum at Meralco Theater

  44. Slide 44: Ground Work Activities

    Ground Work Activities Leaflets distributed to customers Poster Type Collaterals for Kiosks and Building Work Sites Filipino English

  45. Slide 45: Ground Work Activities

    Ground Work Activities Safety Message Fan distributed to customers Back Front Public Safety Flash Animation (link https://www.youtube.com/watch?v=GhwHb8R7MGk ) 5

  46. Slide 46: Tri-media and Other Engagements

    Tri-media and Other Engagements Power line safety discussions during Broadcasters’ Forum CNN Philippines guesting

  47. Slide 47: Tri-media and Other Engagements

    Tri-media and Other Engagements Social Media Public Safety Tips

  48. Slide 48: What I can do?

    WHAT I CAN DO?

  49. Slide 49: Immediately report dangers before an accident could occur

    IMMEDIATELY REPORT DANGERS BEFORE AN ACCIDENT COULD OCCUR

  50. Slide 50: Share what you have learned

    SHARE WHAT YOU HAVE LEARNED

  51. Slide 51: Do not hesitate to contact us

    DO NOT HESITATE TO CONTACT US SMS : 0920-9716211 (Smart) 0925-7716211 (Sun) 0917-5516211 (Globe) Social Media: Facebook.com/Meralco Twitter.com/Meralco