Nextpower Inc. · NASDAQ:NXT
Nextpower — NEXTracker — Greentech Media Webinar: Maximizing PV System Performance with Single-Axis Trackers (June 2018)
44 slides from Nextpower's conference presentation, Jun 21, 2018

Slide 1: Maximizing PV System Performance with Single-Axis Trackers
Maximizing PV System Performance with Single-Axis Trackers Presented By: 6/21/2018 Speakers: Dan Shugar, Founder & CEO, NEXTracker Venkata Abbaraju, Senior Director of Product Development, NEXTracker Dustin Shively, Director of Engineering, Clenera, LLC Moderator: Scott Moskowitz, Senior Analyst, So

Slide 2: Audience Console
Audience Console Speaker Bios Submit Questions Download Slides/ Additional Resources www.greentechmedia.com -1-

Slide 3: Today's Speakers
Today’s Speakers Dan Shugar Venkata Abbaraju Dustin Shively Scott Moskowitz Founder & CEO, Senior Director of Director of Engineering, Senior Analyst, Solar NEXTracker Product Development, Clenera, LLC GTM Research NEXTracker www.greentechmedia.com -2-

Slide 4: Solar Tracker Demand Continues to Grow and Diversify
Solar Tracker Demand Continues to Grow and Diversify Global Solar Tracker Project Installations 2015 to 2022E, MWdc 30,000 25,000 20,000 Annual Installations (MWdc) 15,000 10,000 5,000 0 2015 2016 2017 2018E 2019E 2020E 2021E 2022E Europe North America Asia-Pacific Latin America Middle East Africa T

Slide 5: Trackers Will Also Continue to Gain Share Relative to Fixed Tilt Racking
Trackers Will Also Continue to Gain Share Relative to Fixed Tilt Racking Ratio of Fixed Tilt to Trackers Used in Ground Mount Projects Globally, 2015 to 2022E 100% Percent of Ground Mount Installations 90% 80% 70% 63% 61% 62% 72% 68% 60% 80% 84% 85% 50% 40% 30% 20% 37% 39% 38% 28% 32% 10% 20% 16% 15

Slide 6: Tracker Shipments Jumped in 2017 to 14.6 GW, NEXTracker Leads the Market
Tracker Shipments Jumped 32 Percent in 2013 to 14.6 GW, NEXTracker Leads the Market Global PV Tracker Shipments by Technology Type 2015-2017 Global PV Tracker Market Shares by Shipments for Full-Year 2017 (MWdc) 100% 90% Percent of Global Tracker Shipments NEXTracker 80% Array Technologies 70% Solte

Slide 7: Take 15 Percent Off GTM's Upcoming Events with Code WEBINAR
Take 15 Percent Off GTM’s Upcoming Events with Code WEBINAR

Slide 8: Maximizing PV System Performance
MAXIMIZING PV SYSTEM PERFORMANCE Driving LCOE reduction through bifacial and smart system control Scott Moskovitz, GTM Dustin Shively, Clenera Venkata Abbaraju & Dan Shugar, NEXTracker Greentech Media Webinar June 21st, 2018 Copyright ©2018 NEXTracker

Slide 9: NEXTracker, a Flex Company
NEXTRACKER, A FLEX COMPANY N. America > 8.5 GW An investment grade company India & EMEA > 1.5 GW • $25B revenue • $13B balance sheet S. America > 1 GW • > $400M free cash flow Australia > 1.5 GW Offices Manufacturing: 175 MW/ week global capacity 13 GW trackers delivered globally 10 GW of Gen2 NX Ho

Slide 10: The Imperative for Ongoing Yield Gain
THE IMPERATIVE FOR ONGOING YIELD GAIN • Scaling has driven PV CapEx ferociously, but much of industry at unsustainably low margins • Competitive LCOE most important driver in utility scale sector • Trackers , especially 1 axis horizontal, most optimal for lowest LCOE 8minutenergy 300 MW Eagle Shadow

Slide 11: Creating Value thru Innovation & Connectivity
CREATING VALUE THRU INNOVATION & CONNECTIVITY TrueCapture builds on prior NX technology including independent rows, self-powered smart tracker, and data connectivity with NERP-CIP Compliance Independent Rows Self Grounded Self Powered & Predictive Analytics & TrueCapture™ Smart Balanced Tracker Trac

Slide 12: Real World Conditions Can Limit Production
REAL WORLD CONDITIONS CAN LIMIT PRODUCTION Row-to-Row Height Variances The World is Not Flat • Terrain undulations • As-Built construction variances • Nearby geographic features Diffuse Irradiance • Overcast/ clouds • Fog • Heavy haze or pollution Real-world project - diffuse light conditions Propri

Slide 13: Shading Under Traditional Backtracking
SHADING UNDER TRADITIONAL BACKTRACKING Site w/ Variable Slope Morning and Afternoon Shading Proprietary and Confidential ©2018 12

Slide 14: Row-to-Row Height Variations
ROW-TO-ROW HEIGHT VARIATIONS (undulation or construction tolerance) Proprietary and Confidential ©2018 13

Slide 15: TrueCapture Control System
TRUECAPTURE CONTROL SYSTEM ROW-TO-ROW TRACKING DIFFUSE TRACKING TrueCapture eliminates shading losses Proprietary and Confidential ©2018 14

Slide 16: TrueCapture Energy Yield Benefit
TRUECAPTURE ENERGY YIELD BENEFIT Shade avoidance benefit Diffuse light benefit Shade avoidance benefit 900 800 700 POWER PER MW (KW/MW) Non-curtailment period: 600 Additional energy generated during morning backtracking 500 Non-curtailment period: 400 Additional Additional energy energy generated 30

Slide 17: TrueCapture Case Study: Perspective of a Developer, Owner, and Operator
TrueCapture Case Study: Perspective of a Developer, Owner, and Operator Dustin Shively, Director of Engineering Clenera Renewable Energy

Slide 18: Clēnera Growing Across America
Clēnera Growing Across America Cost, efficiency, and team driving explosive growth • Acquisitions & Greenfield Development • Asset Manager & Operations • 630 MW-DC Installed Capacity • 18 plants operating and in construction • Over 1,500 MW-DC planned construction for 2018 & 2019 • 5 GW in developme

Slide 19: Solar continues to grow in the SE
Solar continues to grow in the SE AL Solar A • 111 MW-DC • 1,100 acres • Energy produced is equivalent to approx. 20,000 homes • Energy solar to Alabama Power • Connects to 115kV transmission Due to terrain, some parts of the plant experience row-to-row shading at certain times of the day.

Slide 20: Lafayette, Alabama – 115 MW
LAFAYETTE, ALABAMA – 115 MW 19

Slide 21: Alabama 115MW DC Site: TrueCapture Generated 4.3% More Energy
Alabama 115MW DC Site: Representative Clear Sunny Day: TrueCapture Generated 4.3% More Energy Production (R2R Only) Lafayette Alabama Inverter Block 304 2.2MW AC Inverter | DC:AC = 1.45 2500 Morning Afternoon TrueCapture Gain TrueCapture Gain 2000 DC Power (kW) 1500 1000 500 0 6:00 7:00 8:00 9:00 10

Slide 22: Alabama 115MW DC Site 3-Month Period
Alabama 115MW DC Site 3-Month Period TrueCapture Generated 3.23% more energy Production Overall (R2R Only) 16 18 TrueCapture Standard Tracking Cumulative Additional Energy 115MW Site | Alabama MWh Additional Energy Generated per MW 14 16 14 5% 4.71 % 12 5% MWh Energy Production/ MW AC 4% 1.48% 12 10

Slide 23: TrueCapture Additional Case Studies & Benefits
TrueCapture Additional Case Studies & Benefits Dan Shugar & Venkata Abbaraju NEXTracker Proprietary and Confidential ©2018 22

Slide 24: Clipping vs. DC/AC Ratio to TrueCapture
CLIPPING VS. DC/AC RATIO TO TRUECAPTURE: Clipping has almost no effect Almost all TrueCapture gain occurs during off-peak time (during backtracking and cloudy conditions): Row-to-Row Gain(Meas.) Diffuse Gain(est.) 6% TrueCapture gain over Std tracking System 4.98% 4.90% 4.71% 5% 4.43% 1.48% 1.48% 1.

Slide 25: TrueCapture Benefit: Other Case Studies
TRUECAPTURE BENEFIT: OTHER CASE STUDIES Mississippi (74 MW): 3.5% More Energy 35 12 30 Additional MWh per MW (Cumulative) TrueCapture Standard Tracking Cumulative TrueCapture Gain 10 25 MWh Generated per MW 8 20 6 15 D.E. Shaw Renewable Investments Bryan Martin, CEO 4 10 Bloomberg New Energy Finance

Slide 26: TrueCapture Benefit with CdTe PV Modules - Tennessee Site
TRUECAPTURE BENEFIT WITH CdTe PV MODULES - TENNESSEE SITE Ø Row-to-Row benefit currently not used with CdTe technology Ø CdTe technology yields more diffuse benefit due to superior spectral response Annual Diffuse only benefit % (Simulated) 1.8% 1.5% Mono - Si CdTe Proprietary and Confidential ©2018

Slide 27: Resiliency for Unexpected Atmospheric Disturbances
RESILIENCY FOR UNEXPECTED ATMOSPHERIC DISTURBANCES TrueCapture can reduce production impacts attributable to volcanic eruptions, fires, dust storms and El Nino conditions by dynamically operating the PV plant Wild fire impacts on PV energy production. Source: GTM Proprietary and Confidential ©2018 2

Slide 28: Bifacial History Highlights
BIFACIAL HISTORY HIGHLIGHTS • Japanese researcher H. Mori proposed bifacial in 1960 • 20 kW Solarex beta bifacial array at PVUSA in 1990 • Sanyo commercialized HIT for PowerLight in 2006 • PowerLight designed bifacial optimized trackers in 2007 Proprietary and Confidential ©2018 27

Slide 29: 2007: 14 MW Nellis Airbase PV, Las Vegas, NV
2007: 14 MW NELLIS AIRBASE PV, LAS VEGAS, NV • Largest PV in USA at time • Included 2 MW Sanyo bifacial • Used PowerLight T-20 Tracker with 2P design, tilt • Measured good bifacial gains of 12%+ due to low GCR and high albedo • Visited by Pres. Obama 2009 Proprietary and Confidential ©2018 28

Slide 30: Springs Preserve Bifacial Project, 2008
SPRINGS PRESERVE BIFACIAL PROJECT, 2008 • Site is a Las Vegas area water history museum; open to public • PowerLight EPC & tracker manufacturer • Horizontal tracker over tube with tilted PV • White reflective fabric doubling as shade for cars • Up to 17% measured bifacial gains PowerLight tilted 1 a

Slide 31: Bifacial Cell and Module Technology Today
BIFACIAL CELL AND MODULE TECHNOLOGY TODAY Industry Finally Moving Toward Bifacial at Scale • Bifacial cells increasingly available & efficient • Many PV manufacturers moving from Al-BSF to high quantum efficiency designs with HIT, PERC, IBC. • Cell enablers: high quality Mono, better quality multi c

Slide 32: NX Horizon: Conceptualized as a Bifacial Tracker
NX HORIZON: CONCEPTUALIZED AS A BIFACIAL TRACKER • One portrait design for maximum albedo capture • Modules suspended between Piers and bearings • Rails: Tall, short, and tapered away from module, which is held OFF the tube • Tube is round, 5” diameter, reflective Testing rear tube effect at Center

Slide 33: NX Center for Solar Excellence: Established in 2013
NX CENTER FOR SOLAR EXCELLENCE: ESTABLISHED IN 2013 • Technology showcase and R&D center 64 PV and inverter and battery technologies in field, four different tracker manufacturers, 5 inverters, 4 battery types • Testing facility Extended lifecycle reliability, multiple storage technologies, bifacial

Slide 34: Torque Tube Impact on Energy Yield
TORQUE TUBE IMPACT ON ENERGY YIELD Module glass For Standard Bifacial Modules Module frame • 6.5% rear shade factor used in PVSyst modeling Torque tube • Optimized tube and mountain rail configuration • Negligible back-side energy impact from tube due to round profile, distance from module, and refl

Slide 35: NX Horizon Bifacial Gain Up to 14%
NX HORIZON BIFACIAL GAIN UP TO 14% 4 years of field testing at Center for Solar Excellence, Fremont, CA (NX HQ) Module A Module B Month Bifacial gain (90% Bifacial gain bifacial) (70% bifacial) January ’17 5.99% February ‘17 7.29% March ’17 13.8% 7.34% April ’17 14.0% 5.34% May ’17 14.4% 4.99% June

Slide 36: PVsyst Now Models Bifacial + Tracker
PVSYST NOW MODELS BIFACIAL + TRACKER Factors influencing Bifacial yield: Bifacial Gain on NX Horizon • Albedo 10.0% 9.0% • View Factor 8.0% 7.0% • GCR (yield vs. land) 6.0% Annual kWh boost vs. monofacial • Array Height (yield vs. structure cost) 5.0% 4.0% • PV array height-to-width ratio 3.0% • PV

Slide 37: 1 x Portrait Trackers Collect More Back-Side Irradiance
1 x PORTRAIT TRACKERS COLLECT MORE BACK-SIDE IRRADIANCE Hypothetical Scenario: Both trackers installed at same height • Back-side irradiance function of tracker height/width ratio 96 W/m^2 74 W/m^2 Average back-side irradiance Average back-side irradiance 123 123 119 119 103 103 99 99 85 85 78 78 68

Slide 38: 1 x Portrait Trackers Collect More Back-Side Irradiance
1 x PORTRAIT TRACKERS COLLECT MORE BACK-SIDE IRRADIANCE Real World: Designed to clearance height 600mm Horizon 2P 4,000mm 2,000mm 2,370mm 59% Panel height 1,500mm height- 75% Panel height to-width height- ratio to-width ratio NX Horizon 2P Tracker Proprietary and Confidential ©2018 37

Slide 39: PVsyst Analysis: NX Horizon vs. 2P Tracker
PVSYST ANALYSIS: NX HORIZON vs. 2P TRACKER Energy Production w/ Bifacial Panels 0.3% NX Horizon vs. 2P Tracker More 2,400 35% Energy 2,395 30% vs. 2P 2,390 2,385 25% 2,380 20% View Factor Production kWh/kWp Back-Side Specific 2,375 Modeled with PV Syst v6.72 15% • Blythe CA 2,370 • TMY3 weather data

Slide 40: Clipping vs DC/AC for Monofacial & Bifacial
CLIPPING VS DC/AC FOR MONOFACIAL & BIFACIAL Most of the bifacial yield occurs during mid-day, when inverters reach peak power Bifacial Gain Monofacial Clipping Loss Bifacial Clipping Loss 15% Percent difference w.r.t Standard MonoFacial on NX 10.01% 8.99% 10% 5.33% 3.62% 5% 2.69% 0.0% -1.2% 0% 1 1.1

Slide 41: NEXTracker Recommendations for Maximum Yield
NEXTRACKER RECOMMENDATIONS FOR MAXIMUM YIELD 4 Low Profile Rail 1 1 Module in Portrait Tracker 3 30-40% GCR* + Round Tube 2 Framed modules 5 7 Consider Storage* 6 ~1.25 DC/AC Ratio* 1.5M Array Height* Daily Production w/ Bifacial Gain NX Flow NX Drive *Site & project variables impact optimal values

Slide 42: Framed Modules Are Best for Trackers
FRAMED MODULES ARE BEST FOR TRACKERS General Framed Advantages for Trackers: • Faster installation time with less breakage • Improved module reliability. Note: UL1703 is a static test, real world has dynamic loads • No slippage and less risk of damage in high wind situations • Thinner glass = less w

Slide 43: TrueCapture + Bifacial: A Winning Combination
TRUECAPTURE + BIFACIAL: A WINNING COMBINATION FIXED VS TRACKER Monofacial Sp. Yield Bifacial Gain TrueCapture BIFACIAL STUDY 2700 +3.5% Site Conditions 2500 Location: Desert Southwest Specific Yield kWh/kWp Albedo: 38% +11% 2300 NX Horizon System GCR: 35% 2100 Bifaciality: 85% +22% 1900 +5% Fixed Fi

Slide 44: Q & A
Q&A 754 MW NEXTracker System Villanueva, Mexico Client: ENEL Green Power Proprietary and Confidential ©2018 43
Source: Internet Archive copy of nextracker.com
More decks from Nextpower Inc.
Shareholder Meeting (August 2026)11 slides · Aug 18, 2026
Q1 2027 Earnings Presentation25 slides · Jul 30, 2026
Merger or Acquisition (June 2026)11 slides · Jun 22, 2026
Merger or Acquisition (May 2026)22 slides · May 28, 2026
Q4 2026 Earnings Presentation24 slides · May 12, 2026
Q3 2026 Earnings Presentation23 slides · Jan 27, 2026