FMC Corporation · NYSE:FMC

FMC — 2012 RE NOx and Combustion Round Table and Expo

56 slides from FMC's conference presentation, Apr 27, 2012

  1. Slide 1: NO Oxidation and Capture with Wet and Dry Scrubbers

    Slide 1: NO Oxidation and Capture with Wet and Dry Scrubbers

    NO Oxidation and Capture with Wet and Dry Scrubbers Bob Crynack – FMC Sterling Gray – URS 2012 RE NOx and Combustion Round Table and Expo April 27, 2012 PerNOxide is a mark of FMC Corporation

  2. Slide 2: Agenda

    Slide 2: Agenda

    Agenda • Overview of Post Combustion NOx controls • Overview of Oxidation Technologies • FMC PerNOxide Technology • Wet Chemistry Research • Dry Chemistry Research • Economic Analysis • PerNOxide Advantages & Challenges • Applications • Summary April 27, 2012

  3. Slide 3: Post Combustion Technologies

    Slide 3: Post Combustion Technologies

    Post Combustion Technologies • Selective Catalytic Reduction - SCR • Selective Non-Catalytic Reduction – SNCR • Others, including FMC’s PerNOxide April 27, 2012

  4. Slide 4: SCR

    Slide 4: SCR

    SCR MC ENVIRONMENTAL SOLUTIONS April 27, 2012

  5. Slide 5: NOx Control Options – SCR

    Slide 5: NOx Control Options – SCR

    NOx Control Options – SCR April 27, 2012

  6. Slide 6: SCR

    Slide 6: SCR

    SCR • Inject NH3 ahead of catalyst – Anhydrous or aqueous • NO chemically reduced to N2 • 4NO + 4NH3 + O2 → 4N2 + 6H2O • NO + NO2 + 2NH3 → 2N2 + 3H2O • NOx reductions of 75-90% • Excess NH3 can react with SO3 to form ammonium bisulfate (NH4HSO4) – Causes air preheater and catalyst fouling • Catalyst

  7. Slide 7: SNCR

    Slide 7: SNCR

    SNCR MC ENVIRONMENTAL SOLUTIONS April 27, 2012

  8. Slide 8: NOx Control Options – SNCR

    Slide 8: NOx Control Options – SNCR

    NOx Control Options – SNCR April 27, 2012

  9. Slide 9: SNCR

    Slide 9: SNCR

    SNCR • Injection at high temperatures in boiler • Injection temperature is critical - ~1400 - 2000 °F • Usually multiple injection levels to get close to temperature “sweet spot” under varying operating conditions • Urea or NH3 injected. No catalyst needed • 4NO + 4NH3 +O2 → 4N2 + 6H2O • 2NO + (NH2)

  10. Slide 10: Oxidation Technologies

    Slide 10: Oxidation Technologies

    Oxidation Technologies April 27, 2012

  11. Slide 11: NOx Control Options – Oxidation

    Slide 11: NOx Control Options – Oxidation

    NOx Control Options – Oxidation April 27, 2012

  12. Slide 12: NOx Capture by Wet Scrubber

    Slide 12: NOx Capture by Wet Scrubber

    NOx Capture by Wet Scrubber • Not new. Considered since 1970s when scrubbers became popular and technologists were looking for “multi-pollutant” use of scrubbers • NO is not water soluble • Oxidation of NO can lead to many N species – NO2, N2O5, HNO3, HNO2 • NO2 is water soluble, but less than SO2 •

  13. Slide 13: Ozone (O3) Oxidation

    Slide 13: Ozone (O3) Oxidation

    Ozone (O3) Oxidation • Ozone generation required • NO + O3 → NO2 + O2 • 2NO2 + O3 → N2O5 + O2 • N2O5 + H2O → 2HNO3 • HNO3 is highly water soluble • Technologies: – LoTOx, Lextran, Comply 2000, Power Span ECO • All inject at low temperatures • Claim up to 90% NOx reduction April 27, 2012

  14. Slide 14: PerNOxide Process

    Slide 14: PerNOxide Process

    PerNOxide Process • Inject hydrogen peroxide (H2O2) • Normal decomposition: H2O2 → H2O + 1/2 O2 • At elevated temperatures dissociates into – H2O2 → 2 OH • – H2O2 → OOH • + H • Oxidizes NO to NO2 and N2O5 • Can achieve > 80% oxidation • Up to 70% NOx reduction with wet scrubbers • Up to 50% NOx redu

  15. Slide 15: Hydrogen Peroxide (H2O2)

    Slide 15: Hydrogen Peroxide (H2O2)

    Hydrogen Peroxide (H2O2) • Strong, environmentally friendly oxidizing agent • Major end uses: pulp & paper, chemicals, food, hair treatment, antiseptic, and electronics • Product provided in various grades and concentrations • North American Capacity – 850,000 tons/yr – FMC is a leading North Americ

  16. Slide 16: Peroxide Characteristic

    Slide 16: Peroxide Characteristic

    Peroxide Characteristic • Specific gravity: 1.2 • Weight: 10 #/gal @ 50% concentration • Apparent pH: ≤ 3.0 • Freezing point: -62 °F @ 50% concentration April 27, 2012

  17. Slide 17: Peroxide Injection

    Slide 17: Peroxide Injection

    Peroxide Injection • Injected into duct between economizer and APH inlet • Concentration controlled to achieve required NOx reduction • Two fluid nozzles (air assisted atomization) used to produce fine droplets • Water evaporates and peroxide dissociates • NO oxidized April 27, 2012

  18. Slide 18: Simplified Process Flow Diagram

    Slide 18: Simplified Process Flow Diagram

    Simplified Process Flow Diagram April 27, 2012

  19. Slide 19: Injection Lances

    Slide 19: Injection Lances

    Injection Lances April 27, 2012

  20. Slide 20: Injection Ports

    Slide 20: Injection Ports

    Injection Ports April 27, 2012

  21. Slide 21: NOx Capture Options

    Slide 21: NOx Capture Options

    NOx Capture Options • NOx Capture Enhancement – Wet lime / limestone / sodium scrubbers – Circulating Dry Scrubbers (CDS) – Spray Dryer Absorbers (SDA) April 27, 2012

  22. Slide 22: PerNOxide Process Development

    Slide 22: PerNOxide Process Development

    PerNOxide Process Development • NASA Patent 6,676,912 – Use of peroxide to oxidize NO to soluble species – FMC has exclusive license from NASA • 3 full scale demonstrations • FMC & URS Collaboration – Process development – Technology demonstrations – Commercial applications • FMC testing at EERC on

  23. Slide 23: Full Scale Demo Conclusions

    Slide 23: Full Scale Demo Conclusions

    Full Scale Demo Conclusions • High NO oxidation up to 80% • Disappointing NOx reduction ~20% • Need to understand wet scrubber chemistry April 27, 2012

  24. Slide 24: URS Wet Chemistry Study

    Slide 24: URS Wet Chemistry Study

    URS Wet Chemistry Study April 27, 2012

  25. Slide 25: URS Test Program Objectives

    Slide 25: URS Test Program Objectives

    URS Test Program Objectives • Conduct Bench-Scale FGD Testing – Quantify effect of solution comp. on NOx removal – Key Variables: Liquid sulfite, pH, buffer additives, thiosulfate • Perform Computer Modeling of FGD Chemistry – Process material balances – Aqueous Chemical and Physical Properties Mode

  26. Slide 26: Bench-Scale Test Conditions

    Slide 26: Bench-Scale Test Conditions

    Bench-Scale Test Conditions • Flue Gas “Bubbler” Contactor • Contactor Adjusted to Representative Levels – Max removal of ~98% SO2; ~ 70% NO2 • Flue Gas Composition: – Simulated flue gas (O2, SO2) – 40 ppm NO, 70 ppm NO2 • Solution Composition: – Dissolved sulfite: 0 – 9,000 mg/l – Solution pH: 5 –

  27. Slide 27: NOx Removal Efficiencies

    Slide 27: NOx Removal Efficiencies

    NOx Removal Efficiencies April 27, 2012

  28. Slide 28: NOx Removal in Wet Scrubbers

    Slide 28: NOx Removal in Wet Scrubbers

    NOx Removal in Wet Scrubbers • Higher-order nitrogen oxides are very soluble with removal efficiencies > 95% • NO2 is less soluble, but removal is enhanced by dissolved sulfite • Reaction products include: – Nitrate, S-N species, N2 gas • Dissolved sulfite levels must be elevated using scrubber addi

  29. Slide 29: Pilot Wet Scrubber Test Program

    Slide 29: Pilot Wet Scrubber Test Program

    Pilot Wet Scrubber Test Program • Being conducted in 1stQ - 2012 • Use URS pilot wet scrubber (slip-stream) • NO2 Addition to simulate Oxidation • Test NO2 capture relative to FGD chemistry – Sodium – Lime, inhibited oxidation – Limestone, Inhibited oxidation – Limestone, forced oxidation • Assess l

  30. Slide 30: Pilot Wet Scrubber Diagram

    Slide 30: Pilot Wet Scrubber Diagram

    Pilot Wet Scrubber Diagram April 27, 2012

  31. Slide 31: Pilot Wet Scrubber System

    Slide 31: Pilot Wet Scrubber System

    Pilot Wet Scrubber System April 27, 2012

  32. Slide 32: Dry Chemistry Study

    Slide 32: Dry Chemistry Study

    Dry Chemistry Study April 27, 2012

  33. Slide 33: Pilot Combustor Specifications

    Slide 33: Pilot Combustor Specifications

    Pilot Combustor Specifications • Combustor – Coal or natural gas – 555,000 #/hr, 130 scfm • Reaction tower – Simulate duct residence time • SDA – rotary atomizer – 8 second treatment time • FF – Pulse jet – A/C ratio of 4 – Teflon bags with Teflon membrane April 27, 2012

  34. Slide 34: Pilot test system sample points diagram

    Slide 34: Pilot test system sample points diagram

    BAG SAMPLE POINT #2 | NO, NO2, 802, 02 ECOM RESIDENCE TIME CHAMBER SAMPLE POINT #4 803 CCM SAMPLE POINT #3 NO, NO2, S02, 02 ECOM ~- SPRAY DRIER SAMPLE POINT #5 SAMPLE POINT #6 ABSORBER Nox, 802, 02 NO, NO2, $02, 02 (SDA) CEMS ECOM SAMPLE POINT 47

  35. Slide 35: Purpose of Test Program

    Slide 35: Purpose of Test Program

    Purpose of Test Program • NOx oxidation – Comparison to full scale test programs • NOx capture • Parametric study – Fuel – Natural gas, Bit, Sub-bit, Lignite coal – Treatment time: 0.5 – 2.0 sec – Temperature: 600 – 900 °F – Peroxide molar ratio:1.0 - 4.0 – SO2 concentration: 0 – 2000 ppm April 27,

  36. Slide 36: Residence Time Affect w/ Lignite Fuel

    Slide 36: Residence Time Affect w/ Lignite Fuel

    Residence Time Affect w/ Lignite Fuel@ Baghouse Out (T=800°F, SO,=?ppm, MR=1.5) NOx Removed (%) NO, Removed (%) 3 Ss xs | ® 0.0 0.5 1.0 1.5 2.0 2.5 Residence Time (s) FMC ENVIRONMENTAL SOLUTIONS April 27, 2012

  37. Slide 37: Molar Ratio Effect w/ E. Bit. Fuel

    Slide 37: Molar Ratio Effect w/ E. Bit. Fuel

    Molar Ratio Effect w/ E. Bit. Fuel @ Baghouse Out (T=831°F, SO,=634ppm, t=2.0s) NOx Removed (%) NO, Removed (%) 3 gS x 0.0 1.0 2.0 3.0 4.0 5.0 Molar Ratio (H,0,:NO,) FMC ENVIRONMENTAL SOLUTIONS April 27, 2012

  38. Slide 38: Molar Ratio Effect w/ PRB Fuel

    Slide 38: Molar Ratio Effect w/ PRB Fuel

    Molar Ratio Effect w/ PRB Fuel @ Baghouse Out (T=802°F, SO,=731ppm, t=2.0s) NOx Removed (%) NO, Removed (%) 3 gS x e 0.0 1.0 2.0 3.0 4.0 5.0 Molar Ratio (H,0,:NO,) FMC ENVIRONMENTAL SOLUTIONS April 27, 2012

  39. Slide 39: Molar Ratio Effect w/ Lignite Fuel

    Slide 39: Molar Ratio Effect w/ Lignite Fuel

    Molar Ratio Effect w/ Lignite Fuel @ Baghous Out (T=800°F, SO,=?ppm, t=2.0s) v 50.0% — g - 30.0% NOx Removed (%) NO, Removed (%) 1.0 1.5 2.0 2.5 3.0 3.5 Molar Ratio (H,0,:NO,) FMC ENVIRONMENTAL SOLUTIONS April 27, 2012

  40. Slide 40: Conclusions from EERC Program

    Slide 40: Conclusions from EERC Program

    Conclusions from EERC Program • EERC pilot is a good system to evaluate NOx oxidation and capture across SDA/FF system – limitations of pilot scale • Better oxidation and capture with – Higher temperature – Higher SR – Longer treatment time • Variations with fuels – Lignite better • No effect of SO2

  41. Slide 41: Economic Comparisons

    Slide 41: Economic Comparisons

    Economic Comparisons April 27, 2012

  42. Slide 42: NO Oxidation Projections

    Slide 42: NO Oxidation Projections

    NO Oxidation Projections April 27, 2012

  43. Slide 43: NO2 Capture Projections

    Slide 43: NO2 Capture Projections

    NO2 Capture Projections April 27, 2012

  44. Slide 44: Technology Cost Comparison

    Slide 44: Technology Cost Comparison

    Technology Cost Comparison April 27, 2012

  45. Slide 45: Annualized Costs

    Slide 45: Annualized Costs

    Annualized Costs April 27, 2012

  46. Slide 46: Cost Effectiveness Analysis

    Slide 46: Cost Effectiveness Analysis

    Cost Effectiveness Analysis April 27, 2012

  47. Slide 47: Take Aways…

    Slide 47: Take Aways…

    Take Aways… • PerNOxide is cost-effective alternative to SCR for modest NOx reductions • PerNOxide economics more favorable for … – Lower inlet NOx levels – Smaller unit size – Lower capacity factor – Sodium and lime scrubbers – Space constrained site (difficult retrofit) • PerNOxide can be final “l

  48. Slide 48: PerNOxide Advantages and Challenges

    Slide 48: PerNOxide Advantages and Challenges

    PerNOxide Advantages and Challenges April 27, 2012

  49. Slide 49: PerNOxide Technology Advantages

    Slide 49: PerNOxide Technology Advantages

    PerNOxide Technology Advantages • Lower capital & maintenance costs than SCR • Higher removal efficiencies than SNCR • Operational flexibility • Mercury oxidation and capture • Immune to SCR catalyst poisons • Environmentally friendly reagent • Limited downtime for installation • Project execution <

  50. Slide 50: PerNOxide Technology Challenges

    Slide 50: PerNOxide Technology Challenges

    PerNOxide Technology Challenges • Developing Technology • May Require Modification to FGD Chemistry • Possible Increase in NO2 Emissions • Possible Increase in SO3 Formation • Waste Stream Management April 27, 2012

  51. Slide 51: PerNOxide Bridges NOx Control Gap

    Slide 51: PerNOxide Bridges NOx Control Gap

    PerNOxide Bridges NOx Control Gap April 27, 2012

  52. Slide 52: PerNOxide Bridges NOx Control Gap

    Slide 52: PerNOxide Bridges NOx Control Gap

    PerNOxide Bridges NOx Control Gap April 27, 2012

  53. Slide 53: Summary

    Slide 53: Summary

    Summary • PerNOxide technology is a 2-Step Process – Oxidation of NO to NO2 and other N-O forms – Capture of NO2 and other N-O forms • High NO oxidation achieved using peroxide • Capture of NO2 is critical – Bench scale testing to explore NO2 Removal – Key variables: Scrubber mass transfer, dissolve

  54. Slide 54: Summary

    Slide 54: Summary

    Summary • Economics are favorable compared to SCR • Example 400 MW plant: – Capital costs 1/10th that of SCR – Annualized costs 1/3rd that of SCR – Cost effectiveness ($/ton) half that of SCR – Incremental SCR costs > $10,000/ton NOx • Favorable economics driven by: – Low capital costs – Moderate (3

  55. Slide 55: Path Forward

    Slide 55: Path Forward

    Path Forward • FMC and URS seeking opportunities for full scale demonstrations on both wet and dry scrubber applications April 27, 2012

  56. Slide 56: Thank You!

    Slide 56: Thank You!

    Thank You! Questions??? Bob Crynack robert. crynack@ fmc.com Sterling Gray sterling.gray@urs.com April 27, 2012

Source: Internet Archive copy of environmental.fmc.com

More decks from FMC Corporation

All 103 FMC decks