ILEX Medical Ltd. · TASE:ILX
ILEX Medical — Technical Presentation (November 2015)
19 slides from ILEX Medical's technical presentation, November 2015

Slide 1: ASM
ASM

Slide 2: Server Module
Server Module The asm system comprises a server module . . . Input/output device Samples can be loaded and unloaded manually via the server door Access up to 40 racks at one time Samples can be delivered automatically to a Microlab STAR liquid handling workstation or a 3rd party device via

Slide 3: Store Module
Store Module … Linked to a store module Compatible with most labware High-speed picking, thawing, & return rates Picking within a temperature-controlled, inert environment

Slide 4: Store Module Expansion - MODULAR
Store Module Expansion - MODULAR As your library expands, you can add new Store modules (up to 5 total); there is no need to purchase excess capacity today based on estimates of your requirements tomorrow.

Slide 5: Storage Conditions
Storage Conditions asm provides optimum conditions to help ensure sample integrity Choose the controlled environment best suited to your needs: Ambient (room) temperature to minus 20° C Inert gas environment option maintains very low humidity within the storage environment (Nitrogen or dry air

Slide 6: Storage conditions
Storage conditions Storage conditions and tubes/plates can be freely combined SW Plates 0.5ml tubes 0.5ml tubes 1.4ml tubes 1.4ml tubes -20 Deg C +4 Deg C +4 Deg C -20 Deg C -20 Deg C

Slide 7: asm STORE
asm STORE asm STORE Can store up to 200,000 microtubes or 2,200 micro-plates Is compatible with all major tube types and SBS standard plates Provides high-speed picking, thawing, & return rates: - 120 racks of tubes or microplates/hour - 300 to 1,000 tubes/hour Performs picking within a temp

Slide 8: asm STORE
asm STORE Storage Capacity and Formats • 99,840 1.4 ml microtubes • 140,000 0.7 ml microtubes • 207,360 0.5 ml microtubes • 103,000 Cryo tubes • 24,960 4 ml vials • 2,160 Microplates • 1,040 Deepwell plates • Capable of storing any SBS format rack

Slide 9: Adaptive picking technology (APT)
Adaptive picking technology (APT) If less than 50% of one rack is needed, the asm picks the required tubes from the Cache Source Target source to the target rack. If more than 50% is needed, the unneeded tubes Cache Source Target are picked to Cache positions and the source becomes the target ra

Slide 10: System Throughput
System Throughput 120 racks of tubes or microplates/hour 300 to 1,000 tubes/hour

Slide 11: asm Server Module Tubes
asm Server Module Tubes

Slide 12: asm Server Module Tubes
asm Server Module Tubes •INSIDE THE SERVER •Active plate/rack detection with sensors •Door shelves - 40 positions Input Output Active thawing • Track to TubeStore • 8 cache positions • 1D barcode reader • 2D barcode reader - 4 positions

Slide 13: asm Server Tubes: Comprehensive Validation
asm Server Tubes Comprehensive Validation 1D and 2D barcode confirmation on input - Checks against input file request - Handles scrambled (spilled) tubes 1D and 2D barcode confirmation on output - Checks against output file request Rapid self-audit of entire library - Checks against database

Slide 14: asm Server Tubes/Plates
asm Server Tubes/Plates • 40 position manual rack pulls out for loading and unloading • Transfer station: automated input/output

Slide 15: Sample Management Software
Sample Management Software Established Based on our more than 100 installed systems over 5 years Simple User Interface Error recover Customized Reporting Alerts, Logs, and Backups API

Slide 16: Software
Software Project wizard walks the user through all necessary steps needed to run a method Create a new project Edit a project Delete a project Preview rack map Validate a project Initiate the start of project

Slide 17: Water uptake/Crysallisation
Water uptake/Crysallisation Samples remain in inert conditions during the complete storage/picking process Picked racks remain in inert conditions – this allows running pick-jobs over night to have tubes available in the morning asm Server allows in- and output of tubes and/or plates at the sa

Slide 18: The complete solution for compound storage
The complete solution for compound storage

Slide 19: Example workflow for a completely housed system
Example workflow for a completely housed system asm Store asm Server Decapper ML STAR 8 5 7 3 6 Sealer 2 4 1 Centrifuge 1: Sample tubes are picked according 5: Tubes are decapped to a worklist 6: Samples are processed on the STAR 2: Tubes are thawed in the server 7: Daughter/Assay plates a