Skkynet Cloud Systems, Inc. · OTC:SKKY
Skkynet Cloud Systems — Technical Presentation
20 slides from Skkynet Cloud Systems's technical presentation

Slide 1: DataHub: OPC UA Alarms and Conditions and OPC DA A&E conversion
Xavier Mesrobian D ATA H U B ® VP Sales and Marketing xavier.mesrobian@skkynet.com OPC UA Alarms and Conditions and OPC DA A&E conversion Andrew Thomas CTO Andrew.thomas@skkynet.com

Slide 2: Logistics
• You are currently on mute • Please use Q&A to ask a question • Please use Chat for LOGISTICS assistance or if you have an immediate concern • Copies of the presentation and webinar link will be emailed to you SECURE INDUSTRIAL IoT REDEFINED 2

Slide 3: Agenda
• Brief overview of DataHub 10 • Discuss the new features of AGENDA Alarms and Conditions • Live demo SECURE INDUSTRIAL IoT REDEFINED 3

Slide 4: DataHub Version 10 Overview
• MQTT Client • MQTT Broker D ATA H U B ® • External Historian VERSION 10 • Alarms and Notifications • OPC UA A&C Overview SECURE INDUSTRIAL IoT REDEFINED 4

Slide 5: MQTT Client: New features and enhancements
MQT T CLIENT New features and enhancements • DataHub now supports MQTT Sparkplug B • Edge of Network (EoN), Primary Application, Non-Primary application. • Configure Read-only • Datahub now supports store and forward • Where the local Historian is InfluxDB • Added an import from CSV for easy point c

Slide 6: MQTT Broker: New features and enhancements
MQT T BROKER New features and enhancements • Completely re-architected in DataHub 10 • Now support +5,000 connections • DataHub now supports MQTT Sparkplug B • Resolves out of order messages • Resolves failed EoN writes • Resolves write failures • Configurable as Read-only • Datahub now supports mul

Slide 7: External Historians: New functionality
EXTERNAL New functionality HISTORIANS • External Historian can be configured to default any supported external historian • DataHub now supports many external historians • AVEVA Insight / AVEVA Historian (Wonderware ) • InfluxDB OSS / Enterprise / Cloud (v1 and v2) • OSI Pi • REST API • Amazon Kinesi

Slide 8: Alarms and Notifications: New feature
ALARMS AND New feature N O T I F I C AT I O N S • Allows you to generate alarms, events and notifications for conditions based on data point values. • When a condition is met, a notification can be emitted by changing a data point or sending email, SMS, OPC A&E or social media messages • Works with

Slide 9: Alarms & Conditions: New feature
OPC UA ALARMS & New feature CONDITIONS • OPC UA A&C • Act as both server and client • Convert between UA and Classic • Mix OPC UA and OPC Classic systems • Consistent acknowledgement • Aggregation • Tunneling • Redundancy • Alarm generation SECURE INDUSTRIAL IoT REDEFINED 10

Slide 10: Protocol conversion
OPC UA A&C Protocol conversion • OPC UA and Classic are not perfectly convertible OPC UA A&C OPC Classic A&E Custom fields Properties Attributes Sub-conditions Description + severity Sub-conditions Acknowledgement Acknowledgement + Confirmation Acknowledgement Branches All branches treated as parent

Slide 11: Client configuration
OPC UA A&C Client configuration • Connection parameters same as DA • Data Transfer section is ignored • Item Selection must be manual • No nodes selected • Alarms and Conditions enabled • Data domain matches server • Accept incomplete ack is optional SECURE INDUSTRIAL IoT REDEFINED 12

Slide 12: Server configuration
OPC UA A&C Server configuration • Enable • Same data domain as: • UA A&C and Classic A&E server • Protocol conversion • UA A&C and Classic A&E client • Protocol conversion • Notification • Alarm generation SECURE INDUSTRIAL IoT REDEFINED 13

Slide 13: Aggregation
OPC UA A&C Aggregation • Configure all UA and Classic client connections to write to the same data domain • Name collisions will cause failures • Source name • Event name • Condition name SECURE INDUSTRIAL IoT REDEFINED 14

Slide 14: Tunneling
OPC UA A&C Tunneling • Tunnel the alarm data domain • Operates like any other tunnel SECURE INDUSTRIAL IoT REDEFINED 15

Slide 15: Redundancy
OPC UA A&C Redundancy • Two clients write to separate data domains • Alarm sources must produce the same alarms • Client domains are redundancy inputs • Output must match server data domain SECURE INDUSTRIAL IoT REDEFINED 16

Slide 16: Alarm Generation
OPC UA A&C Alarm Generation • Uses the Notification feature • Single- and multi-state alarms • Pattern driven – create once, apply broadly • Execute scripts for state enter, exit, acknowledge • Simultaneously produces: • OPC UA A&C • OPC Classic A&E • Email, SMS, REST • Data changes SECURE INDUSTRIA

Slide 17: DataHub Live Walkthrough
D ATA H U B ® LIVE WA L K T H O U G H SECURE INDUSTRIAL IoT REDEFINED 18

Slide 18: About Skkynet
• 20,000+ installations in 86 countries • Used by 10 of 10 top automation providers worldwide • Certified AVEVA technology partner with ABOUT many case studies available on our website SKKYNET • OEM relationships with many hardware and software providers • Covering energy, discreet manufacturing, Cr

Slide 19: Cogent DataHub
C O G E N T D ATA H U B ® Connects to virtually any industrial system using OPC, Modbus TCP, MQTT, and ODBC to support networking, server- server bridging, aggregation, data logging, redundancy and any cloud connection https://cogentdatahub.com SECURE INDUSTRIAL IoT REDEFINED 20

Slide 20: Thank You
• Visit our website at cogentdatahub.com • Learn about DataHub version 10: • https://cogentdatahub.com/products/datahub- THANK YOU version-10/ • Learn more about OPC UA A&C: Secure Real-Time Data • https://cogentdatahub.com/products/notifications/opc-ua-ac- Communication for the support/ Industrial