NetApp, Inc. · NASDAQ:NTAP
NetApp — Technical Presentation (June 2023)
38 slides from NetApp's technical presentation, June 2023
Slide 1: FAS2820 SE Presentation
FAS2820 SE Presentation AFF and FAS PM and TME Team (ng-aff-fas-pm-tme-team) June 2023 Version 1.1.2 © 2023 NetApp, Inc. All rights reserved. — NETAPP CONFIDENTIAL —
Slide 2: Notice of NDA Content
Notice of NDA Content The slides herein contain company confidential, proprietary information of NetApp and shall not be disclosed outside NetApp without a binding nondisclosure agreement in place. These documents are for viewing purposes only and shall not be distributed. 2 © 2023 NetApp, Inc. All
Slide 3: Topics covered in order
Topics covered in order • Architecture, positioning, and performance overview • Specification maximums • Technical details • Ports, motherboard, field replaceable parts (FRUs), and NVMEM architecture • Detailed I/O information • Including supported and Best Practice configurations • Software • Envir
Slide 4: Introducing the FAS2820
Introducing the FAS2820 New entry FAS platform • Based on DS212C shelf • 2U enclosure • Two controllers in HA configuration • 12x 3.5” form-factor drive bays 5 © 2023 NetApp, Inc. All rights reserved. — NETAPP CONFIDENTIAL —
Slide 5: FAS2820
FAS2820 New entry FAS systems • Based on the Intel IceLake-D 8-core processor • Provides up to 50% performance increase over the FAS2720 • Leverages existing 12Gb SAS enclosure architecture • Full 12Gbps SAS connectivity to internal and external drives • Uses NVMe M.2 connection for onboard Flash Ca
Slide 6: Introducing the FAS2820
Introducing the FAS2820 HA pair • Processor and memory (per HA pair) • CPU: 16 cores • Memory: 128GB • 8GB is used as NVMEM per controller • Onboard I/O ports (per controller) • 2x SFP28 (25Gb Ethernet): HA and cluster interconnects • 2x 12Gb mini-HD SAS: External storage attachment • 1x Mezzanine s
Slide 7: Performance
Performance ONTAP Systems • Refer to the NetApp Field Portal for ONTAP performance metrics across platforms • ONTAP Hardware Performance Metrics 8 © 2023 NetApp, Inc. All rights reserved. — NETAPP CONFIDENTIAL —
Slide 8: Systems at a Glance: FAS Series
Systems at a Glance: FAS Series HA pair specifications FAS2700 FAS2820 FAS500f FAS8200 FAS8300 FAS8700 FAS9000 Form factor 2U1 2U1 2U1 3U 4U 4U 8U CPU cores 24 16 24 32 40 64 72 Physical memory 64GB2 128GB2 128GB2 256GB2 256GB 512GB 1024GB Max drive count 144 144 48 480 720 1,440 1,440 NVDIMM / NVRA
Slide 9: Cluster node limits
Cluster node limits ONTAP 9.13.1RC1 Homogeneous Clusters NAS SAN Maximum Cluster Nodes FAS2820 24 12 Heterogeneous (Mixed) Cluster NAS SAN Maximum Cluster Nodes FAS2820 AFF A900, FAS9500 AFF A250, FAS500f AFF A220, AFF C190, FAS2750, FAS2720 24 12 AFF A800, AFF A400, FAS8700, FAS8300 AFF A700, AFF A
Slide 10: Aggregate and volume sizes
Aggregate and volume sizes FAS2820 Maximum number of volumes 1,000 Maximum aggregate size 800 TiB Maximum volume size 100 TiB Minimum root volume size 150 GiB 11 © 2023 NetApp, Inc. All rights reserved. — NETAPP CONFIDENTIAL —
Slide 11: Flash limits
Flash limits HA pair FAS2820 Minimum/maximum onboard flash 2TiB Maximum onboard flash + Flash Pool cache 24TiB FAS2820 controllers ship with a 1TB NVMe Flash Cache module per node. 12 © 2023 NetApp, Inc. All rights reserved. — NETAPP CONFIDENTIAL —
Slide 12: In-band SAS management
In-band SAS management • Starting in ONTAP 9, SAS management is now in-band over the SAS paths • Refer to the 12Gb SAS SE Presentation for additional information • Supported on all platforms running ONTAP 9 • Requires IOM12 shelf modules • Separate ACP cabling not needed with in-band management • Ca
Slide 13: Front view: FAS2820
Front view: FAS2820 Bezel Removed Bay 0 Power LED Warning LED Blue LED beacon Shelf ID Bay 11 14 © 2023 NetApp, Inc. All rights reserved. — NETAPP CONFIDENTIAL —
Slide 14: Rear view: FAS2820
Rear view: FAS2820 Default configuration with 25Gb Ethernet mezzanine 15 © 2023 NetApp, Inc. All rights reserved. — NETAPP CONFIDENTIAL —
Slide 15: Controller I/O: FAS2820
Controller I/O: FAS2820 Management Console USB-C USB-A SAS SAS 25GbE Mezzanine slot Additional details present in slide notes. 16 © 2023 NetApp, Inc. All rights reserved. — NETAPP CONFIDENTIAL —
Slide 16: FRU map
FRU map Take a closer look 17 © 2023 NetApp, Inc. All rights reserved. — NETAPP CONFIDENTIAL —
Slide 17: Midplane / block diagram
PCM block diagram Take a closer look Dual Cell Battery SPI SPI DDR4-2933 Flash Flash Memory Socket 2 Flash TPM USB to UART Memory Socket 1 USB-C Serial SFPGA UART UART AST2500 LPC RJ45 BMC USB USB 88E6176 x1 PCIe 1GBASE-T 1G i210 RJ45 Enet SW x1 PCIe IceLake-D 1G i210 HSIO 16x lane PCIe-Gen4 M.2 NVM
Slide 18: NVMEM architecture
NVMEM architecture Persistent write cache • In the event of a dirty shutdown, the NVMEM battery maintains power to the DIMM slots so in-core writes are protected during reboot • In the event of unexpected loss of power • NVMEM battery keeps motherboard powered up temporarily • NVMEM contents are des
Slide 19: NVMEM destage/restage
NVMEM destage/restage ▪ Destaging: NVMEM battery keeps controller powered up during event *********************************** * Pending cached data is detected * * Starting the process to save to * * media... * *********************************** Destage is in progress, please wait .................
Slide 20: Hot-swappable FRUs
Hot-swappable FRUs • Denoted by terracotta (orange) cam lever or thumbscrew • Controllers • Do not turn off PSUs to remove a controller • PSUs • One PSU can provide sufficient power for the HA pair and internal drives 21 © 2023 NetApp, Inc. All rights reserved. — NETAPP CONFIDENTIAL —
Slide 21: Cluster interconnects
Cluster interconnects • Onboard 25GbE ports provide both HA and cluster connectivity • Required for both 2-node switchless cluster (TNSC) and switched cluster configurations • Cannot be used for host network attachment • MetroCluster IP is not supported • Default cluster interconnects are 25GbE port
Slide 22: HA Pair: FAS2820 two-node switchless cluster
HA Pair: FAS2820 Two-node switchless cluster (TNSC) • FAS2820 systems require 2x 25GbE cluster interconnections • HA & cluster interconnects • Connect ports e0a to e0a • Connect ports e0b to e0b 23 © 2023 NetApp, Inc. All rights reserved. — NETAPP CONFIDENTIAL —
Slide 23: HA Pair: FAS2820 two-node switched cluster
HA Pair: FAS2820 Two-node switched cluster • FAS2820 systems require 2x 25GbE cluster interconnections • Connect 25GbE cables to SFP28 switch ports • 10GbE cables (SFP+) are also supported • Attach 1 connection to each controller per switch • HA & cluster interconnects • Switch 1 • FAS2820A-01: e0a
Slide 24: Mezzanine cards
Mezzanine cards Slot configurations Description NetApp P/N 4-port, 10/25Gb Ethernet, SFP28, (RoCEv2) X1166A 4-port, 32Gb Fiber Channel, SFP+ (initiator/target) X1167A 4-port, 32Gb Fiber Channel, SFP+ (target only) X1168A 2-port 10/25Gb Ethernet, SFP28 + 2-port 32Gb FC, SFP+ (initiator/target) X1169A
Slide 25: Onboard SAS ports
Onboard SAS ports • FAS2820 controllers have three onboard 12Gb SAS-3 ports • SAS port 0a is connected to the SAS controller • SAS ports 0b1 and 0b2 are connected to a SAS expander • To implement MP-HA for internal or external storage use SAS ports 0a and 0b1 • Use of SAS port 0b2 is not supported i
Slide 26: MPHA cabling: FAS2820 internal storage
MPHA cabling: FAS2820 Internal storage only • FAS2820 HA pair • Connect ports 0a to 0a between controllers • Connect ports 0b1 to 0b1 between controllers • Use of port 0b2 is not supported • Single stack configuration • 12Gb SAS Cabling • Refer to the 12Gb SAS SE Presentation for additional informat
Slide 27: MPHA cabling: FAS2820 external storage
MPHA cabling: FAS2820 External storage • FAS2820 HA pair • Connect ports 0a and 0b1 to external storage • Use of port 0b2 is not supported • 3x DS212C or DS224C shelves • Single stack configuration • 12Gb SAS Cabling • Refer to the 12Gb SAS SE Presentation for additional information 28 © 2023 NetApp
Slide 28: Using the onboard USB port
Using the onboard USB port • USB 2.0 port enabled in ONTAP on FAS2820 • USB port can be used to • Boot ONTAP if the onboard boot media has failed • Install a release of ONTAP or a firmware service image • The external USB port is only enabled during these activities • Activation is based on specific
Slide 29: USB port use cases
USB port use cases Scenario Prerequisites Command • USB 2.0 device formatted to FAT32 with correct • boot_recovery using the ONTAP image at the ONTAP image.tgz Perform boot device recovery from LOADER prompt LOADER prompt • Not hot pluggable, need to boot to LOADER • Select appropriate ONTAP image a
Slide 30: Software and firmware levels
Software and firmware levels Minimum revisions • ONTAP 9.13.1RC1 • Baseboard Management Controller (BMC) firmware level 17.1P1 • BIOS level 19.2 31 © 2023 NetApp, Inc. All rights reserved. — NETAPP CONFIDENTIAL —
Slide 31: Baseboard Management Controller
Baseboard Management Controller Enhances manageability and RASM • Baseboard Management Controller (BMC) available through Ethernet or serial console connections • FAS2820 leverages an IPMI-compliant BMC in lieu of a Service Processor (SP) • Shares the same Ethernet interface with e0M • Port speed wi
Slide 32: Baseboard Management Controller best practices
Baseboard Management Controller Best practices • Enable BMC NetApp® Active IQ® • Active IQ configuration is inherited from the controller ONTAP • Use system service-processor autosupport show to verify that –is-enabled is set to ‘true’ • BMC utilizes SMTP for Active IQ transmission • Ensure that an
Slide 33: FAS2820 system diagnostics
FAS2820 system diagnostics System diagnostic tool • Diagnostic tool is used after FRU replacement • From the LOADER prompt run boot_diags command to execute system-level diagnostics • ASCII-based menu-driven interface includes a user guide • Replaces the former SLDIAG diagnostic tool set Function De
Slide 34: System diagnostics
System diagnostics SLDIAG • SLDIAG replaces SYSDIAG • Both perform system-level diagnostics • Major differences in SLDIAG • SLDIAG runs from maintenance mode • Has a CLI interface • SYSDIAG booted with a separate binary • Used menu-driven tables • Review the SLDIAG TOI if you perform diagnostics 35
Slide 35: Power architecture
Power architecture • FAS2820 systems have two power supplies (PSUs) • PSUs provide direct power to the chassis • Chassis provides indirect power to each controller and internal HDDs • Air flows in through disks, then splits between power supplies and PCMs • One failed PSU is allowed per chassis • Co
Slide 36: Hardware Universe: Environmental details
Environmental details Power, thermals, weight, dimensions, acoustics, product certificates • For the latest and most complete environmental information, refer to: Hardware Universe (https://hwu.netapp.com) 37 © 2023 NetApp, Inc. All rights reserved. — NETAPP CONFIDENTIAL —
Slide 37: Certification information
Certification information EMI certifications Type Country Test Standards Notes Safety U.S. 60950-1 CAN CAN/CSA-22-2 NO.60950-1 Equivalent to UL 60950 EU EN 60950-1 Emission U.S. FCC part 15, Subpart B, Class A FCC Class A minimum CAN ICES-003 EU EN 55022, Class A Emission of ITE CISPR22 EN 61000-3-2
Slide 38: Thank you
Thank you © 2023 NetApp, Inc. All rights reserved. — NETAPP CONFIDENTIAL —