Atlas Copco Ab Class A · OMXSTO:ATCO_A

Atlas Copco Ab Class A — Technical Presentation (July 2020)

21 slides from Atlas Copco Ab Class A's technical presentation, Jul 28, 2020

  1. Slide 1: Customer Webinar

    Customer Webinar 20200728 CTS SERVICE OPERATION Muhammad Iqbal

  2. Slide 2: Muhammad Iqbal

    Muhammad Iqbal Technical Support Oil Injection Screw Compressors

  3. Slide 3: Compressor installation Do's and Don'ts

    “Compressor installation Do’s and Don’ts” Tips and trick on your compressor installation

  4. Slide 4: Webinar Topic and agenda of Compressor installation Do's and Don'ts

    Webinar Topic and agenda of “Compressor installation Do’s and Don’ts” ▪ Tips and trick of compressors installation ▪ Free discussion – Q/A 4

  5. Slide 5: Tips and Trick on our compressors installations

    Tips and Trick on our compressors installations ▪ Proper ventilation ▪ Dust prevention ▪ Free space around the compressors ▪ Sufficient height for service activities ▪ Foresee lifting capabilities ▪ Easy access to the compressor room ▪ Clean floor space ▪ Always follow installation recommendations 5

  6. Slide 6: Proper ventilation

    Proper ventilation Do . . . . . . • To prevent overheating, good room ventilation is really important • Foresee enough openings of the right dimensions 30℃- 40℃- 50℃↑ Don’ts . . . . . • Compressors and air dryer must not be installed in a room without ventilation • the heat emitted by the compressor

  7. Slide 7: Installation requirements for the compressor room ventilation system

    Installation requirements for the compressor room ventilation system Installation diagram of compressor intake and exhaust system In order that the heat can be discharged in time during the compressor production process, the equipment must meet the related ventilation installation requirements in th

  8. Slide 8: Installation requirements for the compressor room ventilation system

    Installation requirements for the compressor room ventilation system Compressor intake and exhaust system installation precautions The compressors are equipped with independent exhaust ducts to direct the heat generated outside.

  9. Slide 9: Dust prevention

    Dust prevention Do . . . . . . • Keep dust away ! • If necessary add extra dust filters or filter math to the ventilation • Install ducts to supply clean and fresh air and / or remove the heat Don’ts . . . . . • Extended service preventive maintenance • Cleaning air filter and reused

  10. Slide 10: Compressor room environment selection

    Compressor room environment selection Dusty industries: cement, foundry, ceramics, cement mixing, field Risks from dusty environments construction, electrolytic aluminum, Filter Main motor polysilicon, steel, mining, etc. In places with a dusty environment, it is recommended to modify the compressor

  11. Slide 11: Compressor pre-filtration installation requirements

    Compressor pre-filtration installation requirements It is generally not recommended to install a pre-filter screen on the compressor air inlet. If you need to install a pre-filter screen, its surface area must be large enough and it should The pre-filtration surface area be cleaned in time. should b

  12. Slide 12: Free space around the compressors

    Free space around the compressors Do . . . . . . • Space is precious also in a compressor room • But sometimes a lack space can get in the way • Of good maintenance of your compressor. Don’ts . . . . . • Install compressor with very limited and closes spaces • Free access also needed

  13. Slide 13: Compressor installation - Sufficient space

    Compressor installation - Sufficient space

  14. Slide 14: Easy access to the compressor room

    Easy access to the compressor room Do . . . . . . • Space is precious also in a compressor room • But sometimes a lack space can get in the way • Of good maintenance of your compressor. Don’ts . . . . . • Extended service preventive maintenance

  15. Slide 15: Sufficient height for service activity

    Sufficient height for service activity Do . . . . . . • Too little overhead room can cause overheating • Some components need to be accessible from the top Don’ts . . . . . • Put some parts or component on top side of compressors • Do other activity on top side of compressor beside of compressors ma

  16. Slide 16: Foresee for lifting capability

    Foresee for lifting capability Do . . . . . . • Too little overhead room can cause overheating • Some components need to be accessible from the top Don’ts . . . . . • Perform lifting activity without proper tools

  17. Slide 17: Compressor room environment selection

    Compressor room environment selection The compressor room should be equipped with lifting equipment. The lift table weight of the Please read the operating instructions lifting equipment must be and the precautions posted on the greater than the weight of the machine before moving and lifting the co

  18. Slide 18: Clean and flat floor space

    Clean and flat floor space Do . . . . . . • Always keep clean floor space of compressor area • Always keep flat floor and base • Don’ts . . . . . • Dirt and oil spillage at compressor area will be dangerous • Water condensate spillage also will be dangerous

  19. Slide 19: Compressor Condensate pipe connection requirements

    CompressorCondensate pipe connection requirements drain for easy monitoring Do.. Don’ts.. The manual and automatic drainage pipes of the The condensate drain pipes cannot be merged compressor should independently lead to the drainage into a main pipe. The above installation makes it ditch so that wh

  20. Slide 20: Always follow installation recommendations

    Always follow installation recommendations Safety ….. Do . . . . . . • Be safe , hoses or cables can cause tripping • Drains need to be installed correctly so the water can get away • Always follow tolerances and recommendations when connecting the equipment • If you meet any doubt , Atlas Copco can

  21. Slide 21: Committed to Sustainable Productivity

    COMMITTED TO SUSTAINABLE PRODUCTIVITY