Amkor Technology, Inc. · NASDAQ:AMKR

Amkor Technology — Technical Presentation (September 2003)

4 slides from Amkor Technology's technical presentation, September 2003

  1. Slide 1: Thermal Characterization And Design

    Thermal Characterization And Design Enabling a Microelectronic World™

  2. Slide 2: Thermal Testing Capability

    Thermal Testing Capability Wind tunnel facility: Amkor’s closed loop wind tunnel is capable of controlling airflow from 50 to 1600 LFPM and air temperature from 18°C to 65°C. The tunnel spatial uniformity of velocity is ±1% of the mean value. The test section is 12 x 12 inches with a contraction are

  3. Slide 3: Thermal Modeling Capability

    Thermal Modeling Capability Quick Thermal Calculators: Web based quick thermal calculators are available based on empirical data. These calculators use a PC or web interface and do not require thermal experts to run. The accuracy is higher than 85% for all package styles. Parametric models: Turnkey

  4. Slide 4: System Level Thermal Modeling Capability

    System Level Thermal Modeling Capability Computation Fluid Dynamic (CFD): CFD models are used to more closely predict package performance in custom environments. This includes local flow conditions, system packaging and thermal interaction from neighboring components. Compact models: TTI θTI,TO TTO