Abb Ltd. · SIX:ABBN

Abb — Investor Presentation (April 2012)

32 slides from Abb's investor presentation, Apr 3, 2012

  1. Slide 1: MNS3.0 Product presentation

    Alberto Carini, LPLS Italy, March 2012 MNS3.0 Product presentation © ABB Group April 3, 2012 | Slide 1

  2. Slide 2: The ABB Motor Control Center

    MNS3.0 The ABB Motor Control Center Introduction Certification Electrical characteristics Mechanical characteristics MCC Units Reference Granted performances Electrical performances Mechanical Characteristics MCC Cubicles © ABB Group April 3, 2012 | Slide 2

  3. Slide 3: Granted performances

    MNS3.0 Granted performances Introduction 1.2 billion of MNS system installed in Certification Electrical the world since 1973 characteristics Mechanical characteristics MCC Units A long history of tests and certifications Reference ASTA certification for internal arc proof up to 100 kA, 300ms at 690

  4. Slide 4: Electrical performances

    MNS3.0 Electrical performances Introduction Certification Electrical characteristics Mechanical characteristics MCC Units Reference Rated Current 6300A Rated peak withstand current Ipk 250kA Rated short time withstand current Icw 100kA Arc fault containment 100kA x 300ms Rated frequency 50/60Hz © AB

  5. Slide 5: Electrical performances

    MNS3.0 Electrical performances Introduction Certification Electrical characteristics Mechanical characteristics MCC Units Reference Rated insulation voltage Ui 1000Vac – 1500Vdc Rated operating voltage, Ue 690 Vac – 750Vdc Rated impulse withstand voltage 6/8/12kV Overvoltage category II / III / IV D

  6. Slide 6: Electrical performances

    MNS3.0 Electrical performances Introduction Certification Main busbar Electrical characteristics Mechanical Rated current 6300A characteristics MCC Units Reference Peak withstand current 250kA Short-time withstand current 100kA Distribution busbars Rated current 2000A Peak withstand current 176kA Sh

  7. Slide 7: Functional compartments

    MNS3.0 Mechanical characteristics Introduction Certification Functional compartments Electrical characteristics column with ACB breaker Mechanical characteristics MCC Units Reference © ABB Group April 3, 2012 | Slide 7

  8. Slide 8: Functional compartments

    MNS3.0 Mechanical characteristics Introduction Certification Functional compartments Electrical characteristics column with ACB breaker Mechanical characteristics MCC Units Busbar Reference © ABB Group April 3, 2012 | Slide 8

  9. Slide 9: Functional compartments

    MNS3.0 Mechanical characteristics Introduction Certification Functional compartments Electrical characteristics column with ACB breaker Mechanical characteristics MCC Units Busbar Reference Instrumentation © ABB Group April 3, 2012 | Slide 9

  10. Slide 10: Functional compartments

    MNS3.0 Mechanical characteristics Introduction Certification Functional compartments Electrical characteristics column with ACB breaker Mechanical characteristics MCC Units Busbar Reference Instrumentation Air circuit breaker © ABB Group April 3, 2012 | Slide 10

  11. Slide 11: Functional compartments

    MNS3.0 Mechanical characteristics Introduction Certification Functional compartments Electrical characteristics column with ACB breaker Mechanical characteristics MCC Units Busbar Reference Instrumentation Air circuit breaker Cable © ABB Group April 3, 2012 | Slide 11

  12. Slide 12: Functional compartments

    MNS3.0 Mechanical characteristics Introduction Certification Functional compartments Electrical characteristics MCC column Mechanical characteristics MCC Units Reference © ABB Group April 3, 2012 | Slide 12

  13. Slide 13: Functional compartments

    MNS3.0 Mechanical characteristics Introduction Certification Functional compartments Electrical characteristics MCC column Mechanical characteristics Busbar MCC Units Reference © ABB Group April 3, 2012 | Slide 13

  14. Slide 14: Functional compartments

    MNS3.0 Mechanical characteristics Introduction Certification Functional compartments Electrical characteristics MCC column Mechanical characteristics Busbar MCC Units Reference Equipment © ABB Group April 3, 2012 | Slide 14

  15. Slide 15: Functional compartments

    MNS3.0 Mechanical characteristics Introduction Certification Functional compartments Electrical characteristics MCC column Mechanical characteristics Busbar MCC Units Reference Equipment Cable © ABB Group April 3, 2012 | Slide 15

  16. Slide 16: Dimensions (mm)

    MNS3.0 Mechanical characteristics Introduction Certification Dimensions (mm) Electrical characteristics Mechanical Height: 2200 characteristics MCC Units Reference Width: 400, 600, 800, 1000, 1200 Depth: 400, 600, 800, 1000, 1200 Basic grid size (DIN 43660): E=25mm Surface protection Frame: Alu - Zi

  17. Slide 17: Mechanical characteristics

    MNS3.0 Mechanical characteristics Introduction Certification Electrical characteristics Mechanical characteristics MCC Units Reference The cubicles structures and the busbars are fixed with special screw and ESLOCK bolts Maintenance free ! © ABB Group April 3, 2012 | Slide 17

  18. Slide 18: Main busbars position

    MNS3.0 Mechanical characteristics Introduction Certification Main busbars position Electrical characteristics Mechanical Upper characteristics MCC Units Reference Lower Upper & Lower (double busbars system) Busbar Treatment Bare Silvered Sleeved © ABB Group April 3, 2012 | Slide 18

  19. Slide 19: Busbar front access

    MNS3.0 Mechanical characteristics Introduction Certification Busbar front access allow Electrical characteristics wall standing installation and Mechanical characteristics special layout with reduce MCC Units Reference footprint: Back to back : two separated busbar compartments Duplex: one common bu

  20. Slide 20: Multifunction wall

    MNS3.0 Mechanical characteristics Introduction Certification Electrical characteristics Mechanical characteristics MCC Units Reference Multifunction wall: Segregation and insulation of the distribution busbars Segregation of the main busbar from the functional units Free Fault zone: sensible reducti

  21. Slide 21: Protection degree: from IP20 up to IP54

    MNS3.0 Mechanical characteristics : from IP20 up to IP54 Introduction Certification Electrical characteristics Mechanical characteristics MCC Units Reference First digit: protection against Second digit: protection solid foreign objects against Water 0 = No protection 0 = No protection 1 = solid bod

  22. Slide 22: Segregation form up to 4b

    MNS3.0 Mechanical characteristics: segregation form up to 4b Introduction Certification Electrical characteristics Mechanical characteristics MCC Units Reference Form 4b: segregation of the busbars from functional units and between functional units; segregation of the terminals from the functional u

  23. Slide 23: MCC Cubicles

    MNS3.0 MCC Cubicles Introduction Certification Electrical characteristics Mechanical characteristics MCC Units Reference Wide range of solution Fix modules Removable modules (SlimLine) Withdrawable modules © ABB Group April 3, 2012 | Slide 23

  24. Slide 24: MCC Cubicles

    MNS3.0 MCC Cubicles Introduction Switch Position Module position Main and auxiliary circuits Certification Electrical characteristics ON insert All main and control circuit are Mechanical connected characteristics MCC Units Reference OFF Can be locked with 3 All main and control circuit are insert p

  25. Slide 25: Modularity and flexibility

    MNS3.0 MCC Cubicles Introduction Certification Modularity and flexibility Electrical characteristics Mechanical Interchangeable modules characteristics MCC Units Reference Possibility to modify the modules layout with reduce “out of Service” time Modules for industrial drives and Soft starters React

  26. Slide 26: Unit equipped with variable Speed Drive

    MNS3.0 Unit equipped with variable Speed Drive Introduction Certification Electrical characteristics Mechanical characteristics MCC Units Reference MNS offer feeders equipped with variable speed drive type ABB ACS 850 Withdrawable execution up to 55kW, fix version up to 200kW Reduction of the plant

  27. Slide 27: Intelligent feeders

    MNS3.0 Intelligen feeders Introduction Certification Electrical characteristics Mechanical characteristics MCC Units Reference Possibilità di integrare relè multifunzione all’interno dei moduli estraibili Ad esempio ABB M102 completo di tutte le funzioni di Protezione (26, 27, 37, 46, 49, 51LR, 66…)

  28. Slide 28: ….the best choice for: Plant Larbaa, Algeria

    MNS3.0 ….the best choice for: Introduction Certification Electrical characteristics Mechanical characteristics MCC Units Reference Plant Larbaa, Algeria Customer Sonelgaz EPC Ansaldo Energia Segment Power Notes Total installed power 600MW; 280MW in beginning phase plus 380MW of further extension © A

  29. Slide 29: ….the best choice for: 3SUN Solar modules factory

    MNS3.0 ….the best choice for: Introduction Certification Electrical characteristics Mechanical characteristics MCC Units Reference Plant 3SUN Solar modules factory Italy Customer 3SUN (JV Enel Green Power-Sharp-ST) EPC MW Italy Srl Segment Industries Notes First Italian factory for microfilm solar p

  30. Slide 30: ….the best choice for: Shah Gas, Abu Dhabi

    MNS3.0 ….the best choice for: Introduction Certification Electrical characteristics Mechanical characteristics MCC Units Reference Plant Shah Gas, Abu Dhabi Customer ADNOC EPC Saipem, Technicas Reunidas, Samsung Segment COG Notes Target production 1 billion cubic feet a day (cf/d) of sour, or sulphu

  31. Slide 31: ….the best choice for: Colt data center, Italy

    MNS3.0 ….the best choice for: Introduction Certification Electrical characteristics Mechanical characteristics MCC Units Reference Plant Colt data center, Italy Customer Colt Telecomunications Installer Atel Sesti Segment Data Center Notes Total installed power 8MVA; supplied 800 PDUs © ABB Group Ap

  32. Slide 32: © ABB Group April 3, 2012 | Slide 32

    © ABB Group April 3, 2012 | Slide 32

ABB — Investor Presentation (April 2012) on 6ix