DuPont de Nemours, Inc. · NYSE:DD
DuPont de Nemours — DuPont — Technical Presentation (September 2023)
88 slides from DuPont de Nemours's technical presentation, September 2023

Slide 1: DuPont Tyvek WRB Installation Guidelines: Balcony and Deck Waterproofing
DuPont Performance Building Solutions DuPont™ Tyvek® WRB Installation Guidelines Integration with Balcony and Deck Waterproofing Materials Installed BEFORE the Tyvek® WRB For Type III and Type V Wood-Framed Structures Including Multi-Family and Light Commercial Buildings Balconies Decks September 20

Slide 2: Table of Contents
Table of Contents Introduction............................................................................................................................................................. 3 Balcony Underside Air Barrier Installations...................................................................

Slide 3: Introduction and Applicable Products
Introduction This Installation Guideline pertains to wood-framed buildings of any height, Self-Adhered Flashing Products of Type III and Type V construction, including multi-family buildings and light Product Width commercial buildings. See Applicable Structures and Performance Criteria for more inf

Slide 4: Additional Materials and Warranty
Additional Materials Based on Project Requirements, Details, and Specifications1 • Backer Rod • Sealant1 • Adhesive/Primer2 • J-Roller Warranty Please refer to the DuPont Building Envelope Solutions Products 10-Year Limited Warranty for Single-Family, Wood-Framed Multi-Family, and Light Commercial B

Slide 5: Applicable Structures and Performance Criteria
Applicable Structures and Performance Criteria Applicable Structures Water-Resistive Barrier Performance Requirements These Installation Guidelines pertain solely to Wood-Framed Multi-Family and Light These Installation Guidelines pertain to Wood-Framed Multi-Family and Light Commercial Buildings as

Slide 6: Applicable Structures and Performance Criteria
Applicable Structures and Performance Criteria DuPont Building Envelope Solutions Products Installation Considerations for Wood-Framed Multi-Family and Light Commercial Buildings These Installation Guidelines should be used for buildings which meet the applicable structures definitions and performan

Slide 7: Water-Resistive Barrier and Flashing Code Requirements
Water-Resistive Barrier (WRB) Code Requirements The 2021 International Building Code (Section 1402.2 Weather Protection) requires All Tyvek® WRBs have been tested to the following standards: that “exterior walls shall provide the building with a weather-resistant exterior wall • ASTM E2556 Type II S

Slide 8: Additional Codes and General Instructions
Additional Codes and Standards Information for DuPont™ Tyvek® General Instructions Commercial Air and Water Barrier Systems DuPont™ Tyvek® CommercialWrap®, Tyvek® CommercialWrap® D, DuPont™ StraightFlash™, The best time to install Tyvek® WRBs is: and DuPont™ FlexWrap™ were designed for the rigors of

Slide 9: Special Considerations
Special Considerations 8. DuPont Self-Adhered Flashing Products are not intended for through-wall flashing framing/sheathing, exterior gypsum sheathing, or masonry. applications. 21. Tyvek® Tape is a seam tape primarily designed to seal Tyvek® WRB seams. Tyvek® 9. DuPont™ Tyvek® WRBs and DuPont™ Tyv

Slide 10: Special Considerations
Special Considerations 31. DuPont requires that FlexWrap™, FlexWrap™ EZ, and StraightFlash™ be covered within 9 months (270 days) of installation. DuPont requires that DuPont™ Flashing Tape be covered within four months (120 days) of installation. 32. The maximum in-service temperature for DuPont™ T

Slide 11: Key Installation Requirements for Balconies and Decks
Key Installation Requirements for Integrating DuPont™ Tyvek® WRBs at Balconies, Decks, and Related Details Tyvek® WRBs must be properly integrated with waterproofing membranes, flashing • Balcony waterproofing membranes should be installed per manufacturer’s and other water management components (by

Slide 12: Balcony Conditions Covered in this Guide
Balcony Conditions Covered in this Guide While an inset balcony condition is represented in these guides, similar installation requirements also apply to other balcony conditions as shown below. Inset Balcony Inset Balcony: Flush with Adjacent Wall Cantilever Balcony Cantilever Balcony: Flush with A

Slide 13: Self-Adhered Balcony Waterproofing: Step 1
Integration with a Balcony Waterproofing System Installed BEFORE the DuPont™ Tyvek® WRB Wood-Frame Balcony with a Self-Adhered Balcony Waterproofing System This method applies to the following products: DuPont™ Flashing Tape and DuPont™ StraightFlash™ NOTE: Details not to scale. Certain components e

Slide 14: Self-Adhered Balcony Waterproofing: Step 2
Integration with a Balcony Waterproofing System Installed BEFORE the DuPont™ Tyvek® WRB Wood-Frame Balcony with a Self-Adhered Balcony Waterproofing System STEP 2 Installation of Corner Flashing at Balcony-Wall Interface NOTE: For more robust Tyvek® WRB fascia strip terminations, follow the guidance

Slide 15: Self-Adhered Balcony Waterproofing: Step 2 Alternate Option 1
Integration with a Balcony Waterproofing System Installed BEFORE the DuPont™ Tyvek® WRB Wood-Frame Balcony with a Self-Adhered Balcony Waterproofing System STEP 2 – ALTERNATE Option 1: Tyvek® WRB Fascia Strip Termination on Exposed Sheathing This optional method involves terminating the Tyvek® WRB f

Slide 16: Self-Adhered Balcony Waterproofing: Step 2 Alternate Option 2
Integration with a Balcony Waterproofing System Installed BEFORE the DuPont™ Tyvek® WRB Wood-Frame Balcony with a Self-Adhered Balcony Waterproofing System STEP 2 – ALTERNATE Option 2: Tyvek® WRB Fascia Strip Termination on Top of Balcony Plane This optional method involves terminating the Tyvek® WR

Slide 17: Self-Adhered Balcony Waterproofing: Step 3
Integration with a Balcony Waterproofing System Installed BEFORE the DuPont™ Tyvek® WRB Wood-Frame Balcony with a Self-Adhered Balcony Waterproofing System STEP 3 Installation of Self-Adhered Waterproofing System (Over Drip Edge) Installation of Self-Adhered Balcony Waterproofing System (Over Fascia

Slide 18: Self-Adhered Balcony Waterproofing: Step 4
Integration with a Balcony Waterproofing System Installed BEFORE the DuPont™ Tyvek® WRB Wood-Frame Balcony with a Self-Adhered Balcony Waterproofing System STEP 4 Installation of the Tyvek® WRB A. Install the lower course(s) of Tyvek® WRB starting below the balcony according to the Tyvek® WRB Instal

Slide 19: Self-Adhered Balcony Waterproofing: Step 5
Integration with a Balcony Waterproofing System Installed BEFORE the DuPont™ Tyvek® WRB Wood-Frame Balcony with a Self-Adhered Balcony Waterproofing System STEP 5 Installation of the Tyvek® WRB A. Install upper course(s) of Tyvek® WRB according to the Tyvek® WRB Installation Instructions in the appl

Slide 20: Self-Adhered Balcony Waterproofing: Step 6
Integration with a Balcony Waterproofing System Installed BEFORE the DuPont™ Tyvek® WRB Wood-Frame Balcony with a Self-Adhered Balcony Waterproofing System STEP 6 Final Step NOTE: Concrete topping slab, T-bar and other balcony-related accessories not shown. Refer to manufacturer’s instructions for i

Slide 21: Fluid-Applied Balcony Waterproofing: Step 1
Integration with a Balcony Waterproofing System Installed BEFORE the DuPont™ Tyvek® WRB Wood-Frame Balcony with a Fluid-Applied Balcony Waterproofing System This method applies to the following products: DuPont™ StraightFlash™ and DuPont™ Flashing Tape NOTE: Details not to scale. Certain components

Slide 22: Fluid-Applied Balcony Waterproofing: Step 2 Option 1
Integration with a Balcony Waterproofing System Installed BEFORE the DuPont™ Tyvek® WRB Wood-Frame Balcony with a Fluid-Applied Balcony Waterproofing System STEP 2 Option 1: Tyvek® WRB Fascia Strip Termination on Exposed Sheathing NOTE: This step is not required if the fluid-applied waterproofing me

Slide 23: Fluid-Applied Balcony Waterproofing: Step 2 Option 2
Integration with a Balcony Waterproofing System Installed BEFORE the DuPont™ Tyvek® WRB Wood-Frame Balcony with a Fluid-Applied Balcony Waterproofing System STEP 2 Option 2: Tyvek® WRB Fascia Strip Termination on Top of Balcony Plane NOTE: This step is not required if the fluid-applied waterproofing

Slide 24: Fluid-Applied Balcony Waterproofing: Step 3
Integration with a Balcony Waterproofing System Installed BEFORE the DuPont™ Tyvek® WRB Wood-Frame Balcony with a Fluid-Applied Balcony Waterproofing System STEP 3 Installation of Corner Flashing at Balcony-Wall Interface Option 1: When Using Self-Adhered Corner Flashing by Others Option 2: When Usi

Slide 25: Fluid-Applied Balcony Waterproofing: Step 4
Integration with a Balcony Waterproofing System Installed BEFORE the DuPont™ Tyvek® WRB Wood-Frame Balcony with a Fluid-Applied Balcony Waterproofing System STEP 4 Installation of Fluid-Applied Balcony Waterproofing System (Over Drip Edge) Installation of Fluid-Applied Balcony Waterproofing System (

Slide 26: Fluid-Applied Balcony Waterproofing: Step 5
Integration with a Balcony Waterproofing System Installed BEFORE the DuPont™ Tyvek® WRB Wood-Frame Balcony with a Fluid-Applied Balcony Waterproofing System STEP 5 Transitioning Tyvek® WRB over Fluid-Applied Waterproofing NOTE: Tyvek® WRB must not come in contact with other manufacturer’s cured or u

Slide 27: Fluid-Applied Balcony Waterproofing: Step 6
Integration with a Balcony Waterproofing System Installed BEFORE the DuPont™ Tyvek® WRB Wood-Frame Balcony with a Fluid-Applied Balcony Waterproofing System STEP 6 Installation of the Tyvek® WRB A. Install the lower course(s) of Tyvek® WRB starting below the balcony according to the Tyvek® WRB Insta

Slide 28: Fluid-Applied Balcony Waterproofing: Step 7
Integration with a Balcony Waterproofing System Installed BEFORE the DuPont™ Tyvek® WRB Wood-Frame Balcony with a Fluid-Applied Balcony Waterproofing System STEP 7 Installation of the Tyvek® WRB A. Install upper course(s) of Tyvek® WRB according to the Tyvek® WRB Installation Instructions in the app

Slide 29: Fluid-Applied Balcony Waterproofing: Step 8
Integration with a Balcony Waterproofing System Installed BEFORE the DuPont™ Tyvek® WRB Wood-Frame Balcony with a Fluid-Applied Balcony Waterproofing System STEP 8 Final Step NOTE: Concrete topping slab, T-bar and other balcony-related accessories not shown. Refer to manufacturer’s instructions for

Slide 30: Subfloor Decking Overhang Conditions
DuPont™ Tyvek® WRB Installation Instructions (Balcony Applications) Subfloor Decking Overhang Conditions: Tyvek® WRB Fascia Strip Termination NOTE: DuPont™ StraightFlash™ must be used in lieu of DuPont™ Flashing Tape when using a fluid-applid waterproofing system that comes in direct contact with fl

Slide 31: Flashing Beam/Truss Penetrations: Option 1
DuPont™ Tyvek® WRB Installation Instructions (Balcony Applications) Flashing Beam/Truss Penetrations Option 1: Using Pieces of Tyvek® WRB Around Single Framing Members NOTE: A backing support made of solid OSB or wood sheathing must be installed around the framing before the Tyvek® WRB and DuPont Se

Slide 32: Flashing Beam/Truss Penetrations: Option 2
DuPont™ Tyvek® WRB Installation Instructions (Balcony Applications) Flashing Beam/Truss Penetrations Option 2: Using Pieces of Tyvek® WRB Around Multiple Framing Members NOTE: A backing support made of solid OSB or wood sheathing must be installed around the framing before the Tyvek® WRB and DuPont

Slide 33: Flashing Beam/Truss Penetrations: Option 3
DuPont™ Tyvek® WRB Installation Instructions (Balcony Applications) Flashing Beam/Truss Penetrations Option 3: Tyvek® WRB Flap Created Above Framing Members NOTE: A backing support made of solid OSB or wood sheathing must be installed around the framing before the Tyvek® WRB and DuPont Self-Adhered

Slide 34: Balcony Underside Air Barrier: Option 1
DuPont™ Tyvek® WRB Installation Instructions (Balcony Applications) Balcony Underside Air Barrier Installations Option 1: Using a Single Piece of Tyvek® WRB Installed Between Beams/Trusses (Cantilevering Through Wall) This option applies to air barrier installations where the Tyvek® WRB is installed

Slide 35: Balcony Underside Air Barrier: Option 2
DuPont™ Tyvek® WRB Installation Instructions (Balcony Applications) Balcony Underside Air Barrier Installations Option 2: Using Multiple Pieces of Tyvek® WRB Installed Between Beams/Trusses (Cantilevering Through Wall) This option applies to air barrier installations where the Tyvek® WRB is installe

Slide 36: Balcony Underside Air Barrier: Option 3
DuPont™ Tyvek® WRB Installation Instructions (Balcony Applications) Balcony Underside Air Barrier Installations Option 3: Tyvek® WRB Apron Installed Behind Balcony Ledger Board This option applies to air barrier installations where a Tyvek® WRB apron is installed behind the balcony ledger board to o

Slide 37: Balcony Underside Air Barrier: Option 4
DuPont™ Tyvek® WRB Installation Instructions (Balcony Applications) Balcony Underside Air Barrier Installations Option 4: Tyvek® WRB Installed Below Balcony Ledger Board This option applies to air barrier installations where the Tyvek® WRB is installed directly underneath the balcony ledger board. F

Slide 38: Wood-Frame Balcony Low Wall: Step 1
DuPont™ Tyvek® WRB Installation Instructions (Balcony Applications) Wood-Frame Balcony Low Wall This method applies to the following products: DuPont™ Flashing Tape and DuPont™ StraightFlash™ This section of the guide is intended for balcony low wall/parapet wall conditions that intersect a taller a

Slide 39: Wood-Frame Balcony Low Wall: Step 2
DuPont™ Tyvek® WRB Installation Instructions (Balcony Applications) Wood-Frame Balcony Low Wall NOTE: For air barrier installations, follow the guidance in STEP 2 – ALTERNATE prior to installing the self-adhered waterproofing or roofing membrane (by others). STEP 2 A. Install the self-adhered waterp

Slide 40: Low Wall Alternate: Top of Wall Termination Option 1
DuPont™ Tyvek® WRB Installation Instructions (Balcony Applications) Wood-Frame Balcony Low Wall STEP 2 – ALTERNATE (REQUIRED FOR AIR BARRIER INSTALLATIONS) Option 1: Top of Wall Tyvek® WRB Termination NOTE: The following option can also be used with a balcony low wall that is flush with the adjacent

Slide 41: Low Wall Alternate: Top of Wall Termination Option 2
DuPont™ Tyvek® WRB Installation Instructions (Balcony Applications) Wood-Frame Balcony Low Wall STEP 2 – ALTERNATE (REQUIRED FOR AIR BARRIER INSTALLATIONS) Option 2: Top of Wall Tyvek® WRB Termination NOTE: The following option can also be used with a balcony low wall that is flush with the adjacent

Slide 42: Low Wall: Installation of Saddle Flashing
DuPont™ Tyvek® WRB Installation Instructions (Balcony Applications) Wood-Frame Balcony Low Wall STEP 3 Installation of Saddle Flashing NOTE: Some balcony low wall related accessories and components are not shown. NOTE: For a more robust treatment, metal saddle flashing may be embedded in a Refer to

Slide 43: Low Wall: Installation of Tyvek WRB
DuPont™ Tyvek® WRB Installation Instructions (Balcony Applications) Wood-Frame Balcony Low Wall STEP 4 Installation of Tyvek® WRB A. Install upper course of Tyvek® WRB according to the Tyvek® WRB Installation B. Tape all vertical seams of the Tyvek® WRB using Tyvek® Tape. If the Tyvek® WRB is Instru

Slide 44: Low Wall: Final Step
DuPont™ Tyvek® WRB Installation Instructions (Balcony Applications) Wood-Frame Balcony Low Wall STEP 5 Final Step A. Tape Tyvek® WRB seams onto the saddle flashing, self-adhered waterproofing or NOTE: DuPont™ Flashing Tape or DuPont™ StraightFlash™ may be required to obtain a roofing membrane used a

Slide 45: Balcony Low Wall and Railing Attachments
DuPont™ Tyvek® WRB Installation Instructions (Balcony Applications) Wood-Frame Balcony Low Wall and Railing Attachments STUCCO STUCCO METAL LATH DUPONT™ TYVEK® WRB1 INTERVENING LAYER4 OVERLAPPING MIN. 2” ONTO DUPONT™ FLASHING TAPE OR 2” MIN. SELF-ADHERED THROUGH-WALL DUPONT™ STRAIGHTFLASH™ FLASHING

Slide 46: Dropped Beams and Headers Option 1: Step 1
DuPont™ Tyvek® WRB Installation Instructions (Balcony Applications) Balcony Dropped Beams and Headers Option 1: Using DuPont Self-Adhered Flashing Products Across Underside of Beam This option applies to the following products: DuPont™ Flashing Tape, DuPont™ StraightFlash™, and DuPont™ FlexWrap™ Thi

Slide 47: Dropped Beams Option 1: Step 2
DuPont™ Tyvek® WRB Installation Instructions (Balcony Applications) Balcony Dropped Beams and Headers Option 1: Using DuPont Self-Adhered Flashing Products Across Underside of Beam STEP 2 Preparation of Tyvek® WRB on Exterior-Facing Walls A. Make an “I-Cut” in the Tyvek® WRB. For an “I-Cut”, begin w

Slide 48: Dropped Beams Option 1: Step 3
DuPont™ Tyvek® WRB Installation Instructions (Balcony Applications) Balcony Dropped Beams and Headers Option 1: Using DuPont Self-Adhered Flashing Products Across Underside of Beam STEP 3 Installation and Preparation of Tyvek® WRB on Interior-Facing Walls A. Wrap walls according to the Tyvek® WRB In

Slide 49: Dropped Beams Option 1: Step 4
DuPont™ Tyvek® WRB Installation Instructions (Balcony Applications) Balcony Dropped Beams and Headers Option 1: Using DuPont Self-Adhered Flashing Products Across Underside of Beam STEP 4 Installation of DuPont Self-Adhered Flashing Products at Head of Opening A. Cut two (2) pieces of DuPont™ Flashi

Slide 50: Dropped Beams Option 1: Step 5
DuPont™ Tyvek® WRB Installation Instructions (Balcony Applications) Balcony Dropped Beams and Headers Option 1: Using DuPont Self-Adhered Flashing Products Across Underside of Beam STEP 5 Installation of DuPont™ FlexWrap™ Corners at Head of Opening A. Cut four (4) pieces of FlexWrap™ a minimum of 12

Slide 51: Dropped Beams Option 1: Steps 6 and 7
DuPont™ Tyvek® WRB Installation Instructions (Balcony Applications) Balcony Dropped Beams and Headers Option 1: Using DuPont Self-Adhered Flashing Products Across Underside of Beam STEP 6 (IF APPLICABLE) STEP 7 Installation of Drip Cap/Kick-Out Flashing Final Step A. Install a drip cap/kick-out flas

Slide 52: Dropped Beams Option 1: Section View
DuPont™ Tyvek® WRB Installation Instructions (Balcony Applications) Balcony Dropped Beams and Headers Option 1: Using DuPont Self-Adhered Flashing Products Across Underside of Beam NOTE: This method is recommended when the beam does not exceed 10” in depth. Interior Exterior Interior Exterior DUPONT

Slide 53: Dropped Beams Option 2: Step 1
DuPont™ Tyvek® WRB Installation Instructions (Balcony Applications) Balcony Dropped Beams and Headers Option 2: Using Tyvek® WRB Header Piece Across Underside of Beam This option applies to the following products: DuPont™ Flashing Tape, DuPont™ StraightFlash™, and DuPont™ FlexWrap™ This section of t

Slide 54: Dropped Beams Option 2: Step 2
DuPont™ Tyvek® WRB Installation Instructions (Balcony Applications) Balcony Dropped Beams and Headers Option 2: Using Tyvek® WRB Header Piece Across Underside of Beam STEP 2 Preparation of Tyvek® WRB on Exterior-Facing Walls A. Make an “I-Cut” in the Tyvek® WRB. For an “I-Cut”, begin with a horizont

Slide 55: Dropped Beams Option 2: Steps 3 and 4
DuPont™ Tyvek® WRB Installation Instructions (Balcony Applications) Balcony Dropped Beams and Headers Option 2: Using Tyvek® WRB Header Piece Across Underside of Beam STEP 3 STEP 4 Installation of Tyvek® WRB Header Piece Installation of DuPont Self-Adhered Flashing Products Along Wall Interface NOTE

Slide 56: Dropped Beams Option 2: Step 3 Alternate
DuPont™ Tyvek® WRB Installation Instructions (Balcony Applications) Balcony Dropped Beams and Headers Option 2: Using Tyvek® WRB Header Piece Across Underside of Beam STEP 3 – ALTERNATE Installation of Tyvek® WRB Header Piece A. Cut a piece of Tyvek® WRB at least 12” LONGER than the width of the ope

Slide 57: Dropped Beams Option 2: Step 5
DuPont™ Tyvek® WRB Installation Instructions (Balcony Applications) Balcony Dropped Beams and Headers Option 2: Using Tyvek® WRB Header Piece Across Underside of Beam STEP 5 Installation and Preparation of Tyvek® WRB on Interior-Facing Walls A. Wrap walls according to the Tyvek® WRB Installation Ins

Slide 58: Dropped Beams Option 2: Step 6
DuPont™ Tyvek® WRB Installation Instructions (Balcony Applications) Balcony Dropped Beams and Headers Option 2: Using Tyvek® WRB Header Piece Across Underside of Beam STEP 6 Installation of DuPont Self-Adhered Flashing Products at Head of Opening A. Cut a piece of DuPont™ Flashing Tape or DuPont™ St

Slide 59: Dropped Beams Option 2: Step 7
DuPont™ Tyvek® WRB Installation Instructions (Balcony Applications) Balcony Dropped Beams and Headers Option 2: Using Tyvek® WRB Header Piece Across Underside of Beam STEP 7 Installation of DuPont™ FlexWrap™ Corners at Head of Opening A. Cut two (2) pieces of FlexWrap™ a minimum of 12” long. D. Fan

Slide 60: Dropped Beams Option 2: Steps 8 and 9
DuPont™ Tyvek® WRB Installation Instructions (Balcony Applications) Balcony Dropped Beams and Headers Option 2: Using Tyvek® WRB Header Piece Across Underside of Beam STEP 8 (IF APPLICABLE) STEP 9 Installation of Drip Cap/Kick-Out Flashing Final Step A. Install a drip cap/kick-out flashing (by other

Slide 61: Dropped Beams Option 2: Section View
DuPont™ Tyvek® WRB Installation Instructions (Balcony Applications) Balcony Dropped Beams and Headers Option 2: Using Tyvek® WRB Header Piece Across Underside of Beam Interior Exterior DUPONT™ TYVEK® WRB OVERLAPPING DRIP CAP/KICK-OUT FLASHING (IF APPLICABLE) DUPONT™ FLASHING TAPE OR DUPONT™ STRAIGHT

Slide 62: Deck Ledger Board Option 1: Steps 1
Integration with a Deck Waterproofing System Installed BEFORE the DuPont™ Tyvek® WRB Deck Ledger Board Installed BEFORE the Tyvek® WRB Option 1: Installation of DuPont Self-Adhered Flashing Products Behind Ledger Board This option applies to the following products: DuPont™ Flashing Tape, DuPont™ Str

Slide 63: Deck Ledger Option 1: Step 2
Integration with a Deck Waterproofing System Installed BEFORE the DuPont™ Tyvek® WRB Deck Ledger Board Installed BEFORE the Tyvek® WRB Option 1: Installation of DuPont Self-Adhered Flashing Products Behind Ledger Board STEP 2 Installation of DuPont Self-Adhered Flashing Products on Wall NOTE: If a m

Slide 64: Deck Ledger Option 1: Step 3
Integration with a Deck Waterproofing System Installed BEFORE the DuPont™ Tyvek® WRB Deck Ledger Board Installed BEFORE the Tyvek® WRB Option 1: Installation of DuPont Self-Adhered Flashing Products Behind Ledger Board STEP 3 Installation of DuPont™ FlexWrap™ at Rough Opening Sill A. Cut FlexWrap™1

Slide 65: Deck Ledger Option 1: Step 4
Integration with a Deck Waterproofing System Installed BEFORE the DuPont™ Tyvek® WRB Deck Ledger Board Installed BEFORE the Tyvek® WRB Option 1: Installation of DuPont Self-Adhered Flashing Products Behind Ledger Board STEP 4 Installation of the Ledger Board A. Install the ledger board per plans and

Slide 66: Deck Ledger Option 1: Step 5
Integration with a Deck Waterproofing System Installed BEFORE the DuPont™ Tyvek® WRB Deck Ledger Board Installed BEFORE the Tyvek® WRB Option 1: Installation of DuPont Self-Adhered Flashing Products Behind Ledger Board STEP 5 Installation of Self-Adhered or Mechanically-Attached Through Wall Flashin

Slide 67: Deck Ledger Option 1: Step 6
Integration with a Deck Waterproofing System Installed BEFORE the DuPont™ Tyvek® WRB Deck Ledger Board Installed BEFORE the Tyvek® WRB Option 1: Installation of DuPont Self-Adhered Flashing Products Behind Ledger Board STEP 6 Installation of Tyvek® WRB A. Install lower Tyvek® WRB course below the de

Slide 68: Deck Ledger Option 1: Step 7
Integration with a Deck Waterproofing System Installed BEFORE the DuPont™ Tyvek® WRB Deck Ledger Board Installed BEFORE the Tyvek® WRB Option 1: Installation of DuPont Self-Adhered Flashing Products Behind Ledger Board STEP 7 Final Step A. Working from bottom to top, install DuPont™ Tyvek® Tape, DuP

Slide 69: Deck Ledger Option 2: Step 1
Integration with a Deck Waterproofing System Installed BEFORE the DuPont™ Tyvek® WRB Deck Ledger Board Installed BEFORE the Tyvek® WRB Option 2: Installation of a Self-Adhered Membrane (By Others) Behind Ledger Board This option applies to the following products: DuPont™ Flashing Tape, DuPont™ Strai

Slide 70: Deck Ledger Option 2: Step 2
Integration with a Deck Waterproofing System Installed BEFORE the DuPont™ Tyvek® WRB Deck Ledger Board Installed BEFORE the Tyvek® WRB Option 2: Installation of a Self-Adhered Membrane (By Others) Behind Ledger Board STEP 2 Installation of Self-Adhered Membrane (By Others) on Wall NOTE: If metal edg

Slide 71: Deck Ledger Option 2: Step 3
Integration with a Deck Waterproofing System Installed BEFORE the DuPont™ Tyvek® WRB Deck Ledger Board Installed BEFORE the Tyvek® WRB Option 2: Installation of a Self-Adhered Membrane (By Others) Behind Ledger Board STEP 3 Installation of DuPont™ FlexWrap™ at Rough Opening Sill A. Cut FlexWrap™1 at

Slide 72: Deck Ledger Option 2: Step 4
Integration with a Deck Waterproofing System Installed BEFORE the DuPont™ Tyvek® WRB Deck Ledger Board Installed BEFORE the Tyvek® WRB Option 2: Installation of a Self-Adhered Membrane (By Others) Behind Ledger Board STEP 4 Installation of the Ledger Board A. Install the ledger board per plans and s

Slide 73: Deck Ledger Option 2: Step 5
Integration with a Deck Waterproofing System Installed BEFORE the DuPont™ Tyvek® WRB Deck Ledger Board Installed BEFORE the Tyvek® WRB Option 2: Installation of a Self-Adhered Membrane (By Others) Behind Ledger Board STEP 5 Installation of Self-Adhered or Mechanically-Attached Through Wall Flashing

Slide 74: Deck Ledger Option 2: Step 6
Integration with a Deck Waterproofing System Installed BEFORE the DuPont™ Tyvek® WRB Deck Ledger Board Installed BEFORE the Tyvek® WRB Option 2: Installation of a Self-Adhered Membrane (By Others) Behind Ledger Board STEP 6 Installation of Tyvek® WRB A. Install lower Tyvek® WRB course below the deck

Slide 75: Deck Ledger Option 2: Step 7
Integration with a Deck Waterproofing System Installed BEFORE the DuPont™ Tyvek® WRB Deck Ledger Board Installed BEFORE the Tyvek® WRB Option 2: Installation of a Self-Adhered Membrane (By Others) Behind Ledger Board STEP 7 Final Step A. Working from bottom to top, install DuPont™ Tyvek® Tape, DuPon

Slide 76: Deck Ledger Option 3: Step 1
Integration with a Deck Waterproofing System Installed BEFORE the DuPont™ Tyvek® WRB Deck Ledger Board Installed BEFORE the Tyvek® WRB Option 3: Installation of a Self-Adhered Membrane (By Others) Behind Ledger Board and Into the Rough Opening This option applies to the following products: DuPont™ F

Slide 77: Deck Ledger Option 3: Step 2
Integration with a Deck Waterproofing System Installed BEFORE the DuPont™ Tyvek® WRB Deck Ledger Board Installed BEFORE the Tyvek® WRB Option 3: Installation of a Self-Adhered Membrane (By Others) Behind Ledger Board and Into the Rough Opening STEP 2 Installation of Self-Adhered Membrane (By Others)

Slide 78: Deck Ledger Option 3: Step 3
Integration with a Deck Waterproofing System Installed BEFORE the DuPont™ Tyvek® WRB Deck Ledger Board Installed BEFORE the Tyvek® WRB Option 3: Installation of a Self-Adhered Membrane (By Others) Behind Ledger Board and Into the Rough Opening STEP 3 Installation of the Ledger Board A. Install the l

Slide 79: Deck Ledger Option 3: Step 4
Integration with a Deck Waterproofing System Installed BEFORE the DuPont™ Tyvek® WRB Deck Ledger Board Installed BEFORE the Tyvek® WRB Option 3: Installation of a Self-Adhered Membrane (By Others) Behind Ledger Board and Into the Rough Opening STEP 4 Installation of Self-Adhered or Mechanically-Atta

Slide 80: Deck Ledger Option 3: Step 5
Integration with a Deck Waterproofing System Installed BEFORE the DuPont™ Tyvek® WRB Deck Ledger Board Installed BEFORE the Tyvek® WRB Option 3: Installation of a Self-Adhered Membrane (By Others) Behind Ledger Board and Into the Rough Opening STEP 5 Installation of Tyvek® WRB A. Install lower Tyvek

Slide 81: Deck Ledger Option 3: Step 6
Integration with a Deck Waterproofing System Installed BEFORE the DuPont™ Tyvek® WRB Deck Ledger Board Installed BEFORE the Tyvek® WRB Option 3: Installation of a Self-Adhered Membrane (By Others) Behind Ledger Board and Into the Rough Opening STEP 6 Final Step A. Working from bottom to top, install

Slide 82: Deck Waterproofing Installed AFTER Tyvek WRB: Typical Wall Assembly
Integration with a Deck Waterproofing System Installed AFTER the DuPont™ Tyvek® WRB Deck Ledger Board Installed AFTER the Tyvek® WRB TYPICAL WALL ASSEMBLY VINYL SIDING DUPONT™ TYVEK® WRB1 OSB SHEATHING VAPOR RETARDER WOOD STUDS W/BATT INSULATION (WHERE REQUIRED)2 VAPOR RETARDER1 GYPSUM BOARD DUPONT™

Slide 83: Deck Waterproofing Installed AFTER Tyvek WRB: Section View
Integration with a Deck Waterproofing System Installed AFTER the DuPont™ Tyvek® WRB Deck Ledger Board Installed AFTER the Tyvek® WRB TYPICAL WALL ASSEMBLY VINYL SIDING DUPONT™ TYVEK® WRB1 OSB SHEATHING WOOD STUDS W/BATT INSULATION VAPOR RETARDER (WHERE REQUIRED)2 VAPOR RETARDER2 GYPSUM BOARD DUPONT™

Slide 84: Deck Installed at Foundation Wall
Integration with a Deck Waterproofing System Installed AFTER the DuPont™ Tyvek® WRB Deck Ledger Board Installed AFTER the Tyvek® WRB TYPICAL WALL ASSEMBLY VINYL SIDING DUPONT™ TYVEK® WRB1 OSB SHEATHING WOOD STUDS W/BATT INSULATION VAPOR RETARDER VAPOR RETARDER1 (WHERE REQUIRED)2 GYPSUM BOARD DUPONT™

Slide 85: Deck Installed at Foundation Wall: Section View
Integration with a Deck Waterproofing System Installed AFTER the DuPont™ Tyvek® WRB Deck Ledger Board Installed AFTER the Tyvek® WRB TYPICAL WALL ASSEMBLY VINYL SIDING DUPONT™ TYVEK® WRB1 OSB SHEATHING VAPOR RETARDER WOOD STUDS W/BATT INSULATION (WHERE REQUIRED)2 VAPOR RETARDER2 GYPSUM BOARD DUPONT™

Slide 86: Product Composition and UV Stability Design Considerations
Product Composition and Design Considerations In a system where no exterior sheathing Flashing Products are combustible and is used and Tyvek® WRBs are installed should be protected from flames and UV Stability DuPont Building Envelope Solutions directly over the wall studs, exterior other high heat

Slide 87: Safety and Handling; For More Information
Safety and Handling For More Information (continued) Visit the Quick Links section of our website Great Stuff Pro™ polyurethane foam (https://www.dupont.com/building/ sealant and adhesive products contain resources.html) where you’ll find links to isocyanate and a flammable blowing essential documen

Slide 88: Notice and Contact Information
NOTICE: No freedom from any patent owned by DuPont or others is to be inferred. Because use conditions and applicable laws may differ from one location to another and may change with time, Customer is responsible for determining whether products and the information in this document are appropriate f
Source: Internet Archive copy of dupont.com
More decks from DuPont de Nemours, Inc.
Q3 2026 Earnings Presentation23 slides · Nov 3, 2026
Q2 2026 Earnings Presentation23 slides · Aug 4, 2026
Q1 2026 Earnings Presentation26 slides · May 5, 2026
Q4 2025 Earnings Presentation27 slides · Feb 10, 2026
Q3 2025 Earnings Presentation24 slides · Nov 6, 2025
Investor Day (September 2025)81 slides · Sep 18, 2025