Transformers And Rectifiers (india) Limited · NSE:TARIL
Transformers And Rectifiers (india) — Q3 FY2020-21 Earnings Presentation
14 slides from Transformers And Rectifiers (india)'s earnings presentation, Feb 12, 2021
Slide 1: Cover letter to stock exchanges
t I'I1CtlHITx(indill) ltd Date: 12th February, 2021 Ref: TRILl SECT12020-21 I NSE-BSEI COMPL/49 To, To, The Secretary The Secretary BSE Limited National Stock Exchange of India Limited Phiroze Jeejeebboy Towers, Exchange Plaza, C-1, Block G, Dalal Street, Bandra - Kurla Complex, Mumbai - 400001 Band
Slide 2: Q3 - FY 2020-21 - Presentation
An ISO 9001:2015, ISO 14001:2015 & ISO 45001 : 2018 CERTIFIED Q3 - FY 2020-21 - Presentation 12th February, 2021
Slide 3: Disclaimer
DISCLAIMER This presentation and the discussion that follows may contain certain words or phrases that are forward - looking statements, based on current expectations of the management of Transformers and Rectifiers (India) Limited or any of its subsidiaries and associate companies (“TRIL”). Actual
Slide 4: Financials - Standalone
FINANCIALS - STANDALONE Q3 Q3 9M 9M FY Particulars (Rs. in Lakhs) FY 2020-21 FY 2019-20 FY 2020-21 FY 2019-20 2019-20 Revenue from Operations (Gross) 16,394 20,492 45,090 52,132 68,306 Other Income 76 126 300 1,547 1,696 Total Income 16,470 20,618 45,390 53,679 70,002 Expenditure Cost of Raw Materia
Slide 5: Q3 FY 2020-21 Result Highlights
Q3 FY 2020-21 RESULT HIGHLIGHTS Q3 FY 2020-21 Revenue from Operations stood at Rs. 163.94 Cr decreased by 20% as compared to Q3 FY 2019-20 due to delay in shipment of export consignments. EBIDTA stood at Rs. 17.03 Cr as compared to Rs. 15.76 Cr during Q3FY 2019-20 (8% up) due to better gross mar
Slide 6: Financials - Consolidated
FINANCIALS - CONSOLIDATED Q3 Q3 9M 9M FY Particulars (Rs. in Lakhs) FY 2020-21 FY 2019-20 FY 2020-21 FY 2019-20 2019-20 Revenue from Operations (Gross) 16,845 21,084 45,830 53,783 70,095 Other Income 95 113 339 1,499 1,585 Total Income 16,940 21,197 46,169 55,282 71,680 Expenditure Cost of Raw Mater
Slide 7: Q3 FY 2020-21 Result Highlights - Consolidated
Q3 FY 2020-21 RESULT HIGHLIGHTS Consolidated Q3 FY 2020-21 Revenue from Operations stood at Rs. 168.45 Cr decreased by 20% as compared to Q3FY 2019-20. EBIDTA stood at Rs. 18.99 Cr as compared to Rs. 17.53 Cr during Q3FY 2019-20 (8% up) . 9 Month FY 2020-21 Revenue from Operations stood at Rs.
Slide 8: Operational Performance
OPERATIONAL PERFORMANCE Particulars Q3 Q3 9M 9M FY 2019-20 FY 2020-21 FY 2019-20 FY 2020-21 FY 2019-20 Sales MVA Upto 220kV 2440 3014 6886 6374 9008 Above 220kV 1740 1775 5842 6805 8730 Particulars Q3 Q3 9M 9M FY 2019-20 FY 2020-21 FY 2019-20 FY 2020-21 FY 2019-20 Sales Breakup - In Crore % In Crore
Slide 9: Orders in Hand
Orders in Hand The Company has order book valuing Rs. 1015 Crore as on 31st January, 2021 Company is executing export order of Rs. 166 Crs and total execution will complete by Oct / Nov.2021 In continuation of our focus on export business and repetitive export orders executed in the past, Comp
Slide 10: Awards and Recognition
Awards and Recognition Central Power Research Institute (CPRI) is an autonomous body set up under aegis of Ministry of Power, Government of India and is serving Indian power sector for more than 60 years in various areas of Applied research, Testing and Certification of Power Equipment and many more
Slide 11: Strength
STRENGTH Design & engineering capabilities developed indigenously & in-house enabling the company to achieve greater customization and cater to niche segments In-house technical & Designs structured so as to minimize the losses occurring within the transformer design capabilities Unique distin
Slide 12: Product Portfolio
PRODUCT PORTFOLIO Furnace Transformers Rectifier Transformers Distribution Transformers Power Transformers Classification of transformers Range Types Generator transformer, Unit Auxiliary transformers, Step up & Step down transformers, Interconnecting Auto Power Transformer Upto 1200 kV class transf
Slide 13: Testing Lab Facility
TESTING LAB FACILITY INFRASTRUCTURE 1000 Sq. meter, 25 meter high test bay with shielding suitable for partial discharge measurements Test Sources • 3000 kW 50/60 Hz Generator • 250kV Transformer for High Voltage test • 0-170kV Source Transformer for losses measurement • 1500 kW 200Hz Generator • 50
Slide 14: Thank You
An ISO 9001:2015, ISO 14001:2015 & ISO 45001 : 2018 CERTIFIED THANK YOU www.transformerindia.com
Transformers and Rectifiers (India) — Q3 FY2020-21 Earnings Presentation on 6ix