  1. Slide 1: Breakthrough welding solutions for hermetic encapsulation

    Breakthrough welding solutions for hermetic encapsulation

  2. Slide 2: Primoceler – your partner for glass encapsulation

    Primoceler – your partner for glass encapsulation GLASS WELDING UNIT ENGINEERING KNOW-HOW § Laser based welding § Solution specification tool and software for § Laboratory & clean room hermetic encapsulation facilities for testing § Installation and training § Tailored solutions for § Technical supp

  3. Slide 3: Glass encapsulation with vias

    Glass encapsulation with vias § Borosilicate lid, spacer and base plate, thickness 500 µm each § Package was encapsulated with Primoceler welding technique § Volume of the free cavity <0,10 cm3 § Silicon chip and through glass vias (TGV)

  4. Slide 4: Hermeticity test

    Hermeticity test § Radioisotope leak test with krypton 85 was performed at Oneida Research Center § Fine and gross leak was tested Hermeticity test samples Weld seam (side view, etched)

  5. Slide 5: Results

    Results § All the devices passed gross and fine leak testing with leak rates <6,0x10-12 atmcm3/s Kr-85 § MIL standard space limit was evidently fulfilled

  6. Slide 6: Primoceler technology benefits

    Primoceler technology benefits § No adhesive or extra materials § Welding at the material interface § Superior hermeticity § Miniaturization of the end product § High precision without heat affect, no safety zones needed § High quality, homogenous seams § Free geometry of the samples (wafer, square,

  7. Slide 7: Contact for more information

    Contact for more information § Mr. Ville Hevonkorpi § ville.hevonkorpi@primoceler.com § Mobile +385 40 505 7623