  1. Slide 1: SikaRepair 222 Application Instructions

    Construction SikaRepair 222 Application Instructions Sika Corporation

  2. Slide 2: SikaRepair 222

    Construction SikaRepair 222  One-component  Early strength gaining  Cementitious  Patching material for horizontal repair of concrete. Sika Corporation

  3. Slide 3: Where to use

    Construction SikaRepair 222  Where to use: • On, above, and below grade on concrete and mortar. • Repair material for spalled horizontal concrete surfaces, walkways, ramps, steps, etc. Sika Corporation

  4. Slide 4: Packaging and coverage

    Construction SikaRepair 222  Packaging: • SikaRepair SHB - 50 lb. bag. • SikaLatex R – 1 gal. plastic jug.  Coverage: • .42 cu. ft./bag • 726 cu. inches./bag Sika Corporation

  5. Slide 5: Surface Preparation: Cementitious Substrates

    Construction Surface Preparation  Cementitious Substrates: • Should be clean and sound. • Remove contaminants and bond inhibiting materials from repaired area. • Obtain exposed/fractured aggregate surface ~1/8 to 1/4 inch profile (ICRI CSP 6 & above). • Substrate must be saturated surface dry (SSD)

  6. Slide 6: Surface Preparation

    Construction Surface Preparation  Cementitious Substrates: • Surface should be cleaned and roughened to create a profile. Sika Corporation

  7. Slide 7: Surface Preparation: Saw Cut

    Construction Surface Preparation  Saw cut around perimeter of repair area to achieve a minimum 3/8” shoulder.  Eliminates feathered edges giving a clean repair transition Sika Corporation

  8. Slide 8: Surface Preparation: Steel

    Construction Surface Preparation  Steel: • Remove all corrosion and contaminants from exposed steel. • Surface should be cleaned thoroughly by blast cleaning or mechanical means. • Exposed steel should be cleaned to white steel. • If half of the diameter is exposed, chip behind bar, ½” minimum for

  9. Slide 9: Steel Preparation

    Construction Steel Preparation  Steel should be cleaned to a bright metal finish. Sika Corporation

  10. Slide 10: Tools Required

    Construction Tools Required  ½” Drill Motor.  Low speed drill 400-600 rpm.  Large mixing paddle  Margin trowel Sika Corporation

  11. Slide 11: Mixing

    Construction Mixing  Pour Water or Latex R into clean pail.  Leave approximately 1” of Water or Latex R in jug. Sika Corporation

  12. Slide 12: Mixing

    Construction Mixing  Add SikaRepair 222 to pail with Water or Latex R already inside, while mixing continuously. Sika Corporation

  13. Slide 13: Mixing

    Construction Mixing 1. Water or Latex R ¾ -1 gallon of liquid. 2. Start with adding liquid to the mixing container. 3. Slowly add powder. 4. Once all the powder is added mix for 3 minutes. 5. Do not add any more than the recommended liquid. Sika Corporation

  14. Slide 14: Mixing

    Construction Mixing 1. While mixing for 3 minutes stop to scrape after 1.5 minutes down the sides to insure all material is fully mixed. 2. Add additional Water or Latex R for desired consistency. 3. Most cases you will have liquid left. 4. Thorough mixing and proper proportioning is necessary. Sika

  15. Slide 15: SR - Application

    Construction SR 222 - Application  Apply the mortar to the patch area while the Armatec 110 EpoCem is still wet.  If Armatec is not used as a bonding agent, SSD the surface and scrub coat the repair mortar into the substrate filling all pores and voids. Sika Corporation

  16. Slide 16: SR - Application

    Construction SR 222 - Application  Apply scrub coat to substrate, filling all pores and voids  While scrub coat is wet, apply SikaRepair 222  Press mortar behind rebar and make sure the material is consolidated and compacted fully. Sika Corporation

  17. Slide 17: SR - Application

    Construction SR 222 - Application  Complete filling patch area.  Work mortar from the center of the patch to the outside. Sika Corporation

  18. Slide 18: Min / Max application thickness

    Construction Min / Max application thickness  Water and diluted Latex R • Neat Min (1/4 inch) Max (1.0 inch) • Extended Min (1.0 inch) Max (4.0 inch)  Undiluted Latex R • Neat Min (1/8 inch) Max (1.0 inch) • Extended Min (1.0 inch) Max (4.0 inch)  SikaRepair 222 can be extended with aggregate. Si

  19. Slide 19: Finish

    Construction SikaRepair 222 - Finish  After filling patch section, allow mortar to set to desired stiffness.  Then finish with steel, wood, plastic floats, or damp sponge float to attain look required. Sika Corporation

  20. Slide 20: Finish

    Construction SikaRepair 222 - Finish  To assist in the finishing of the SikaRepair use SikaFilm. • SikaFilm is a finishing aid that also retards moisture evaporation. Sika Corporation

  21. Slide 21: Finish

    Construction SikaRepair 222 - Finish  You can use a steel trowel to attain a smooth surface. Sika Corporation

  22. Slide 22: Sponge Float Finish

    Construction Sponge Float Finish  You can use Sponge float to attain a textured surface. Sika Corporation

  23. Slide 23: Curing

    Construction SikaRepair Curing  Cure as per ACI recommendations. Curing is required.  Moist cure with wet burlap and polyethylene, a fine mist of water or water- based curing compound.  Moist curing should commence immediately after finishing.  Protect newly applied material from direct sun ligh

  24. Slide 24: Sika Product Data Sheets

    Construction SikaRepair 222 Sika Product Data Sheets can be obtained via: www.sikaconstruction.com Refer to data sheets for specific information on each Sika product. Sika Corporation