Carrier Global Corporation · NYSE:CARR

Carrier Global — Investor Presentation (December 2018)

30 slides from Carrier Global's investor presentation, December 2018

  1. Slide 1: Smart Heating Production

    —_ ww ———— ( Carrier ») DE s Genelen Gc | N NO VA ty © sO UT 1:0: NS Se mate SMART HEATING PRODUCTION ATWUIA Let ns) a) AQUAFORCE PUREtec

  2. Slide 2: Carrier presents AquaForce PUREtec 61XWHZE

    CARRIER PRESENTS AQUAFORCE® PURETEC™ High temperature water sourced heat-pump with HFO refrigerant 61XWHZE 200 kW to 2500 kW 2

  3. Slide 3: AquaForce, at the heart of smart city

    AQUAFORCE®, AT THE HEART OF SMART CITY

  4. Slide 4: Smart cities to anticipate increasing urbanization

    SMART CITIES TO ANTICIPATE INCREASING URBANIZATION 4

  5. Slide 5: Heat recovery potential for smart cities

    HEAT RECOVERY POTENTIAL FOR SMART CITIES VALUE NATURAL HEAT SOURCE VALUE WASTED HEAT SOURCE  Ground water  Waste heat from data centres  Lake water  Waste heat from grey waters  Sea water  Waste heat from industrial process  Geothermal probes  Waste heat from boilers (wood, gas...)  Waste h

  6. Slide 6: AquaForce, at the heart of smart city

    AQUAFORCE®, AT THE HEART OF SMART CITY 6

  7. Slide 7: Industry-leading Carrier technologies

    INDUSTRY-LEADING CARRIER TECHNOLOGIES

  8. Slide 8: Hot water production

    HOT WATER PRODUCTION The combination of Carrier technology and HFO refrigerant enables to offer high temperature PUREtec™ heat pumps capable of delivering hot water up to 85°C. The 61XWHZE heat pumps can supplement traditional boilers in applications such as: Up to 85°C Commercial building Industria

  9. Slide 9: 61XWHZE range

    — 61XWHZE RANGE EUVUROVENT SW CERTIFIED PERFORMANCE /——— eurovent-certification.com 61XWHZE HEATING CAPACITY* kW 300 484 727 967 1453 1468 1570 LENGTH m 27 3.1 3.3 47 47 48 48 WIDTH m 0.9 14 14 14 1.2 14 14 HEIGHT m 1.6 18 2.0 2.0 2.1 2.3 2.3 In accordance with standard EN1451 1-3:2013. Heating perf

  10. Slide 10: Technical features

    TECHNICAL FEATURES TOUCH PILOT™ CONTROL SCREW COMPRESSOR WITH LIQUID INJECTION PRESSURIZED ELECTRICAL BOX FLOODED SHELL AND TUBE HEAT EXCHANGERS 10 10

  11. Slide 11: HFO, a new generation of refrigerant

    HFO, A NEW GENERATION OF REFRIGERANT  HFO R-1234ze  Long-term solution  Ultra low GWP (<1)  ODP = 0  A2L safety class 11

  12. Slide 12: HFO, a new generation of refrigerant

    HFO, A NEW GENERATION OF REFRIGERANT 50’s 70’s 90’s Today CFC’s HCFC’s HFC’s HFO’s R12… R22… R410A, R134a… very high ODP high ODP ODP = 0 ODP = 0 very high GWP high GWP High GWP GWP nearby 0 EU F-gas Montreal protocol (GWP) (ODP) Montreal protocol (GWP) ODP: Ozone Depletion Potential GWP: Global War

  13. Slide 13: HFO R1234ze(E)

    HFO R1234ZE(E) PURETEC HFO-R1234ze(E) Molecular Formula CF3CH=CHF Appearance Colourless Ozone Depletion Potential (ODP R11 = 1) 0 Global Warming Potential (GWP CO2 = 1) <1 Atmospheric lifetime 18 days ASHRAE Std. 34 Safety Classification A2L Flammability Limits – ASTM E681-04 @ 21°C Non Flammable Fl

  14. Slide 14: HFO credits in green buildings

    HFO CREDITS IN GREEN BUILDINGS BREEAM EXAMPLE  2 credits if refrigerant GWP < 10  3 credits with the DELC CO2 (Direct Effect Life Cost) calculate from TEWI 14

  15. Slide 15: Risk management

    RISK MANAGEMENT LEAKAGE CONDITIONS IGNITION THE PRODUCT INSTALLATION REFRIGERANT DESIGN DESIGN LEAKAGE x CONDITION x x x IGNITION x x 15

  16. Slide 16: HFO R1234ze characteristics

    HFO R1234ZE CHARACTERISTICS  Absence of flammable mixture with air under 30°C of ambience. Example: Non-flammable @ 23°C, 1bar & 50%RH  Difficult to ignite. The minimum ignition energy is ~61,000 mJ  The lower segment 2L category. Higher burning velocity & higher heat combustion implies higher da

  17. Slide 17: A2L product design

    A2L PRODUCT DESIGN Strength and proof New flammability test with new labels refrigerant Update pressure Flame arrestors on vessel calculations ignition sources or and approval qualification testing HFO Installation Control box maintained Service instructions under positive air pressure Literature an

  18. Slide 18: AquaForce, smart heating production

    AQUAFORCE ®, SMART HEATING PRODUCTION

  19. Slide 19: Low total cost of ownership

    LOW TOTAL COST OF OWNERSHIP Up to -20% compared to natural refrigerant Unit cost Installation Energy costs Maintenance & TOTAL costs repair costs Carrier HFO heat-pump Natural refrigerant heat-pump 19

  20. Slide 20: COP single unit

    COP SINGLE UNIT COP from 2.5 up to 5.0 in a single unit configuration 20

  21. Slide 21: COP multiple units

    COP MULTIPLE UNITS COP up to +40% in series counter flow arrangement 21

  22. Slide 22: Flexibility

    FLEXIBILITY Compact design (from 1000 mm wide) to save space into technical rooms. Multiple water connection arrangements for flexible installation in existing technical rooms. High entering water temperature on condenser side (up to 60°C) to connect multiple units in series counterflow arrangement.

  23. Slide 23: Full reliability

    FULL RELIABILITY Every Carrier 61XWHZE heat pump is factory assembled on a dedicated production line, leak-tested and run-tested in a ISO 140001 and ISO 9001 certified factory. Furthermore Carrier 61XWHZE heat pumps performances have been checked in UTC laboratory during the development phase and ar

  24. Slide 24: Governmental support

    GOVERNMENTAL SUPPORT Many government environmental programs provide financial incentives for heat pumps to support renewable heat production in the industry, the district heating sector and at multi-family buildings. RHI Financial (Renewable Heat incentives Incentive) FONDS CHALEUR CEE (Certificats

  25. Slide 25: AquaForce, a tried and trusted solution

    AQUAFORCE ®, A TRIED AND TRUSTED SOLUTION

  26. Slide 26: Project references: Coriance, Le Blanc-Mesnil

    PROJECT REFERENCES CORIANCE, Le-Blanc-Mesnil • France District heating CUSTOMER’S REQUIREMENT Heating capacity of 4.5 MW with a heat pump system connected to a geothermal heat source, located at 2 km depth. Condenser leaving water temperature of up to 85°C. Evaporator entering water temperature of 5

  27. Slide 27: Project references: Bjølsen Energy, Oslo

    PROJECT REFERENCES BJÖLSEN ENERGY, Oslo • Norvège District heating for student housing CUSTOMER’S REQUIREMENT Environmentally responsible solutions able to deliver up to 71°C at brine temperature of 1°C. CARRIER’S SOLUTION 2 AquaForce 61XWHZE heat pumps with PUREtec HFO refrigerant, recovering heat

  28. Slide 28: Project references: YGEO, France

    PROJECT REFERENCES YGEO, Rosny sous bois, Noisy le sec, Montreuil • France District heating CUSTOMER’S REQUIREMENT Heating capacity of 12 MW with a heat pump system connected to a geothermal heat source, located at 1.8 km depth. Condenser leaving water temperature of up to 80°C. Evaporator entering

  29. Slide 29: Customer testimonial

    CUSTOMER TESTIMONIAL Cadziplo Project – First HFO heat-pump installation in Europe (2015) 29

  30. Slide 30: Thank you

    THANK YOU AquaForce® with PUREtec™ - 61XWHZE - English - December 2018. © Carrier 2018. All rights reserved. Carrier reserves the right to change certain information and specifications contained in this document at any time and without prior notice. Since standards, specifications and designs are su