Ion Beam Applications SA · EURONEXT:IBAB

Ion Beam Applications SA — Investor Day (October 2013)

74 slides from Ion Beam Applications SA's investor day presentation, Oct 9, 2013

  1. Slide 1: IBA Capital Markets Day, London, 9 October 2013

    Slide 1: IBA Capital Markets Day, London, 9 October 2013

    Bringing the most advanced radiation therapy to the cancer care market IBA Capital Markets Day London, 9 October 2013

  2. Slide 2: Agenda for the day

    Slide 2: Agenda for the day

    Agenda for the day  14:00  IBA – An Introduction to Proton Therapy and Strategy Olivier Legrain, IBA, Chief Executive Officer  Product Development, IBA’s Technology Road Map Frederic Genin, IBA, Executive VP Product Development  15:30  Short Q&A and coffee break  15:45  Proton Therapy Clinica

  3. Slide 3: IBA in summary

    Slide 3: IBA in summary

    IBA in summary  IBA is a world leading cancer diagnostics and treatment equipment company  Number one provider of integrated proton therapy solutions  Synergistic businesses in dosimetry and accelerators  2012 FY sales of EUR 221 million (EUR 97 million H1 2013) Accelerators 18%  1,200 employee

  4. Slide 4: Investment case

    Slide 4: Investment case

    Investment case  World leader and market pioneer of proton therapy (PT)  25+ years experience in the proton therapy field  Largest installed base, 55% global market share, 74 rooms, 26 institutions  Diverse product offering – Proteus®ONE* leading the market  Significant market growth potential

  5. Slide 5: Proton Therapy

    Slide 5: Proton Therapy

    PROTON THERAPY Olivier Legrain, IBA Chief Executive Officer Protect, Enhance and Save Lives -5-

  6. Slide 6: Proton therapy vs. conventional radiotherapy

    Slide 6: Proton therapy vs. conventional radiotherapy

    Proton therapy vs. conventional radiotherapy Protons have a superior dose distribution  Protons:  Deliver their maximum energy within a precisely controlled range  Deposit a high and conformal dose  Deposit very little entry dose and no exit dose – sparing more healthy tissues  Treatment well s

  7. Slide 7: Proton therapy: higher dose - less side effects

    Slide 7: Proton therapy: higher dose - less side effects

    Proton therapy: higher dose - less side effects 3D CRT Proton Therapy Side Effects* Protons Photons Restrictive Lung Disease 0% 60% Reduced exercise capability 0% 75% Abnormal EKGs 0% 31% Growth abnormality 20% 100% IQ drop of 10 points at 6 yrs 1.6% 28.5% Risk of IQ score < 90 15% 25% * M edullobla

  8. Slide 8: Proton therapy is a growing modality

    Slide 8: Proton therapy is a growing modality

    Proton therapy is a growing modality Rooms 2012 Treatment Capacity : > 20 000 patients(*) 2015 Treatment Capacity : > 50 000 patients(*) (*) Source: PTCOG Protect, Enhance and Save Lives -8-

  9. Slide 9: IBA's proton therapy growth opportunity

    Slide 9: IBA's proton therapy growth opportunity

    IBA’s proton therapy growth opportunity  Affordability, innovation and evidence are key drivers PT more affordable PT driving innovation Proteus®ONE and IBA fast delivery of Pencil Beam Scanning reliable clinical systems Keys to success Proteus®ONE PT delivering evidence E.g. Dutch report Increasin

  10. Slide 10: IBA – The global leader with best experience in PT

    Slide 10: IBA – The global leader with best experience in PT

    IBA – The global leader with best experience in PT Source: PTCOG, Proton Therapy Centers, End 2012 Experience Technology Patients Treated Clinical Rooms Installation Compact PBS Scattering time 1 Room 24,157 45 24 months 6,940 9 > 4 years 1,894 9 > 7 years 1,377 5 > 4 years ? 968 3 > 7 years ? 0 0 >

  11. Slide 11: Broad spectrum proton therapy offering

    Slide 11: Broad spectrum proton therapy offering

    Broad spectrum proton therapy offering Multi-room to single-room solutions Proteus®PLUS Proteus®ONE* 360 m² 1800 m² *Proteus®ONE features PBS, Cone Beam CT and Compact gantry. Protect, Enhance and Save Lives - 11 - *Subject to review by Competent Authorities (FDA, European Notified Bodies, et al.) b

  12. Slide 12: Proteus ONE – Game changing product for IBA

    Slide 12: Proteus ONE – Game changing product for IBA

    Proteus®ONE – Game changing product for IBA Profitable compact PT solution for global adoption A game changer:  Smaller footprint (360m²)  Easier to finance (leasing…)  Faster to install (18 months from order to clinical)  Most advanced clinical features (PBS, CBCT…) As close to a Linac as it ca

  13. Slide 13: Proteus ONE – A reality

    Slide 13: Proteus ONE – A reality

    Proteus®ONE – A reality Profitable PT Solution for global adoption Real accelerator Real gantry Real customers Beam extracted Gantry tested and Shreveport shipped installation started Documentation submitted to FDA Protect, Enhance and Save Lives - 13 -

  14. Slide 14: Proteus ONE – the affordable PT solution

    Slide 14: Proteus ONE – the affordable PT solution

    Proteus®ONE – the affordable PT solution  Affordable  $ 25M for ProteusONE equipment  Profitable  ≈20-40% Internal Rate of Return ProteusONE  Risk acceptable  < 175 patients to break-even vs. capacity of 300+ pat. Protect, Enhance and Save Lives - 14 -

  15. Slide 15: Internal rate of return: ≈20 to 40%

    Slide 15: Internal rate of return: ≈20 to 40%

    Proteus®ONE – the affordable PT solution  Internal rate of return: ≈20 to 40%  Payback: <3.5 years from 1st patient  Break-even (opex+debt): <1.5 year from 1st patient Protect, Enhance and Save Lives - 15 -

  16. Slide 16: Pencil Beam Scanning (PBS)

    Slide 16: Pencil Beam Scanning (PBS)

    Pencil Beam Scanning (PBS) For Intensity Modulated Proton Therapy (IMPT) Arc Therapy Proton Therapy (PBS / IMPT) PBS is the most advanced proton therapy delivery technique PBS technology enables millimeter PBS DEDICATED precision allowing for the proton dose NOZZLE to be sculpted  Better conformity

  17. Slide 17: Pencil Beam Scanning

    Slide 17: Pencil Beam Scanning

    Pencil Beam Scanning The most advanced delivery technique Conformality to target IMPT (PBS) IMXT 3D PT (Scattering) 3D RT Sparing of healthy Protect, Enhance and Save Lives - 17 - tissue (Integral Dose)

  18. Slide 18: Growing international recognition of PT benefits

    Slide 18: Growing international recognition of PT benefits

    Growing international recognition of PT benefits UK Government - Aug, 2013 - Dutch Government - Aug, 2013 - £250m pledged to proton therapy 4 proton therapy sites approved “The Government “A substantial number of recognises that ensuring Dutch cancer patients patients have access to could potentiall

  19. Slide 19: UK Government invests in proton therapy

    Slide 19: UK Government invests in proton therapy

    UK Government invests in proton therapy  Government commits £250 million for Public Health Minister innovative cancer treatment - proton Anna Soubry said: therapy We want the NHS to have  The only PT treating center in the UK at the best cancer treatments available in the this time is the NHS cent

  20. Slide 20: IBA – Spearheading cancer research in partnership

    Slide 20: IBA – Spearheading cancer research in partnership

    IBA – Spearheading cancer research in partnership with a large community of prestigious partners  Community of clinical users defining the future of proton therapy  The broadest collaborative proton therapy research program  A yearly users’ meeting organized to develop proton therapy technology a

  21. Slide 21: Our strategy to remain number one in PT

    Slide 21: Our strategy to remain number one in PT

    Our strategy to remain number one in PT Innovation Global growth Faster clinical Promote Reducing cost and Deliver PT to more delivery awareness size of proton patients in more Deliver cutting Support clinical therapy and countries. Growth edge technology research and enhancing expected in both fast

  22. Slide 22: IBA's Technology Road Map

    Slide 22: IBA's Technology Road Map

    IBA’s Technology Road Map Frederic Genin, IBA, Executive VP Product Development

  23. Slide 23: Realizing the proton therapy advantage: Proteus Product Family

    Slide 23: Realizing the proton therapy advantage: Proteus Product Family

    Roadmap  Realizing the proton therapy advantage Proteus Product Family Proteus® PLUS Proteus® ONE Protect, Enhance, and Save Lives - 23 -

  24. Slide 24: Realizing the PT advantage: PBS Beam (IMPT)

    Slide 24: Realizing the PT advantage: PBS Beam (IMPT)

    Realizing the PT advantage: … PBS Beam (IMPT) All treatment modes with a large focus on active scanning • IBA proposes the largest variety of treatment modes • From scattering (how it was invented 50 years ago) to the most advanced active scanning technique (PBS or IMPT) • We went live with PBS in 2

  25. Slide 25: Realizing the PT advantage – Oropharynx

    Slide 25: Realizing the PT advantage – Oropharynx

    Realizing the PT advantage – Oropharynx IBA PT SYSTEM WITH PBS ADVANCED FORM OF IMRT Tasting food when eating Courtesy of Penn Radiation Oncology, James M Metz, MD - Professor and Vice Chair Protect, Enhance, and Save Lives - 25 -

  26. Slide 26: Realizing the PT advantage – Medulloblastoma / CSI

    Slide 26: Realizing the PT advantage – Medulloblastoma / CSI

    Realizing the PT advantage – Medulloblastoma / CSI IBA PT SYSTEM WITH PBS PROTONS ADVANCED FORM OF IMRT Preserving IQ potential 100 Preserving Skull normal growth Preserving Heart, Lung … X-RAYS 60 10 Protect, Enhance, and Save Lives - 26 -

  27. Slide 27: Realizing the PT advantage – Anal cancer

    Slide 27: Realizing the PT advantage – Anal cancer

    Realizing the PT advantage – Anal cancer IBA PT SYSTEM WITH PBS ADVANCED FORM OF IMRT Complete sparing of genitalia Courtesy of Penn Radiation Oncology James M Metz, MD - Professor and Vice Chair Protect, Enhance, and Save Lives - 27 -

  28. Slide 28: Realizing the PT advantage – the roadmap

    Slide 28: Realizing the PT advantage – the roadmap

    Realizing the PT advantage – the roadmap Cost Size Time to go clinical PT Clinical PBS Beam Usability Guided Therapy Ergonomics Workflows Protect, Enhance, and Save Lives - 28 -

  29. Slide 29: Realizing the PT advantage: from the lab 1960…

    Slide 29: Realizing the PT advantage: from the lab 1960…

    Realizing the PT advantage: from the lab 1960… Protect, Enhance, and Save Lives - 29 -

  30. Slide 30: Realizing the PT advantage: … to IBA clinical in 2001

    Slide 30: Realizing the PT advantage: … to IBA clinical in 2001

    Realizing the PT advantage: … to IBA clinical in 2001 Protect, Enhance, and Save Lives - 30 -

  31. Slide 31: Realizing the PT advantage: … to IBA clinical in 2001

    Slide 31: Realizing the PT advantage: … to IBA clinical in 2001

    Realizing the PT advantage: … to IBA clinical in 2001 Protect, Enhance, and Save Lives - 31 -

  32. Slide 32: Realizing the PT advantage: … to IBA clinical 2011

    Slide 32: Realizing the PT advantage: … to IBA clinical 2011

    Realizing the PT advantage: … to IBA clinical 2011 As easy to use as a LINAC (VersaHD or TrueBeam) Treatments in a few mouse clicks We demonstrate live PT treatment anywhere - 31 -

  33. Slide 33: Realizing the PT advantage: Proteus PLUS

    Slide 33: Realizing the PT advantage: Proteus PLUS

    Realizing the PT advantage: … to IBA clinical 2011 Proteus® PLUS Protect, Enhance, and Save Lives - 33 -

  34. Slide 34: Realizing the PT advantage: Proteus ONE 2014

    Slide 34: Realizing the PT advantage: Proteus ONE 2014

    Realizing the PT advantage: … to IBA clinical 2014 Proteus® ONE Protect, Enhance, and Save Lives - 34 -

  35. Slide 35: Realizing the PT advantage: … PBS (IMPT)

    Slide 35: Realizing the PT advantage: … PBS (IMPT)

    Realizing the PT advantage: … PBS (IMPT) Proteus® PLUS • Universal nozzle Proteus® PLUS • PBS dedicated nozzle • Compact PBS Proteus® ONE dedicated nozzle Protect, Enhance, and Save Lives - 35 -

  36. Slide 36: Realizing the PT advantage: IBA delivers high quality PBS

    Slide 36: Realizing the PT advantage: IBA delivers high quality PBS

    Realizing the PT advantage: IBA delivers high quality PBS IBA is the only PT provider delivering high quality PBS (IMPT) • Smallest spot size  best clinical outcome • Fastest PBS – less than 60s for typical treatment time  organ motion compatibility with gating and repainting • Fastest beam availa

  37. Slide 37: Realizing the PT advantage: IGRT – XR & CBCT

    Slide 37: Realizing the PT advantage: IGRT – XR & CBCT

    Realizing the PT advantage: IGRT – XR & CBCT Protect, Enhance, and Save Lives - 37 -

  38. Slide 38: Realizing the PT advantage: Dose Guided Therapy

    Slide 38: Realizing the PT advantage: Dose Guided Therapy

    Realizing the PT advantage: Dose Guided Therapy Scintillator + Prompt Gamma photodetector Slit collimator Proton pencil beam (scan the tumor, spot by spot, in X, Y, Z) 38 Enhance, and Save Lives Protect, - 38 -

  39. Slide 39: Realizing the PT advantage: Adaptive Therapy

    Slide 39: Realizing the PT advantage: Adaptive Therapy

    Realizing the PT advantage: Adaptive Therapy Personalized medicine  ability to customize a workflow to an individual or more likely to a smaller and smaller group of individuals We must manage this complexity safely and efficiently  The Recipes Protect, Enhance, and Save Lives - 39 -

  40. Slide 40: Realizing the PT advantage: Adaptive Therapy

    Slide 40: Realizing the PT advantage: Adaptive Therapy

    Realizing the PT advantage: Adaptive Therapy Use it as a written What are you using Ability to create and support for daily today? edit current situation operation, training, transfer… Delivering adaptive therapy ASTRO 2013: Make Use those adaPT platform launched it appear on Create the association

  41. Slide 41: Realizing the PT advantage: Reducing size

    Slide 41: Realizing the PT advantage: Reducing size

    Realizing the PT advantage: Reducing size Proteus®PLUS Proteus®ONE* 360 m² 1800 m² *Proteus®ONE features PBS, Cone Beam CT and Compact gantry. - 42- *Subject to review by Competent Authorities (FDA, European Notified Bodies, et al.) before being put on the market.

  42. Slide 42: One example of an outcome that only PT can realize

    Slide 42: One example of an outcome that only PT can realize

    Finally, one example of an outcome that only PT can realize Courtesy Torunn I Yock, MD Burr Proton Therapy Center Boston USA Protect, Enhance, and Save Lives - 42 -

  43. Slide 43: Proton Therapy Clinical Update

    Slide 43: Proton Therapy Clinical Update

    PROTON THERAPY CLINICAL UPDATE Nicolas Denef, IBA Product Manager Protect, Enhance, and Save Lives - 43 -

  44. Slide 44: Our vision of the market: more than 17% of RT patients treated with PT

    Slide 44: Our vision of the market: more than 17% of RT patients treated with PT

    Our vision of the market : more than 17% of RT patients treated with PT ! TODAY PROOF 5-10 YEARS PROOF 15-25 YEARS Reduced Side Effects (12.1% of RT patients) Intracranial GI (Esophagus, H&N gastric, rectal, Urologic pancreas) Lung Lymphoma Accepted standard Breast Sarcoma Reduced 2nd Cancers (0.6%

  45. Slide 45: Pencil Beam Scanning is accelerating market adoption

    Slide 45: Pencil Beam Scanning is accelerating market adoption

    Pencil Beam Scanning is accelerating market adoption Penn Medicine results = More proof generated (since November 2011) 7 new indications added Case Mix : Prostate <25% • Advanced prostate cancer • Rectal cancer 5% GU/prostate 10% • Anal cancer 25% GI tumors 10% • Oropharyngeal cancer Pediatrics • N

  46. Slide 46: Example: OroPharynx Cancer

    Slide 46: Example: OroPharynx Cancer

    Example: OroPharynx Cancer Current state of art : Treatment Patient Type Male, under 60 years (HPV positive) Tumor Stage Locally advanced (Stage III/IV) Standard of are Chemoradiation (5-7 weeks RT) 80% cure rate Side Effects - Fatigue 48% patients require - Loss of taste / weight feeding tubes(*) -

  47. Slide 47: Example: OroPharynx Cancer

    Slide 47: Example: OroPharynx Cancer

    Example: OroPharynx Cancer Proton Therapy reduces feeding tubes by 50% + Long term effect - Reduced Fatigue Side Effects - Reduced Loss of taste / weight 20% feeding tubes only - Reduced Swallowing problems Long term evaluation on-going Proton Therapy IMRT Phase II/III randomized trial on-going : N

  48. Slide 48: Example: Prostate Cancer

    Slide 48: Example: Prostate Cancer

    Example: Prostate Cancer Proton Therapy gives excellent treatment results even with lower doses Prostate Cancer Incidence in UK 120 Patient Type Male, 55+ 100 Rate per 100,000 80 Tumor Stage All stages 60 40 Standard of Care Radiotherapy, surgery, brachytherapy 20 All most 100% cure rate for early s

  49. Slide 49: Example: Prostate Cancers

    Slide 49: Example: Prostate Cancers

    Example: Prostate Cancers Proton Therapy gives excellent treatment results even with lower doses Stage Results Protons Results IMRT (UFPTI) (*) (MSK) (**) Low Risk 99% 97% Disease Free Survival Intermediary Risk 99% 85% High Risk 76% 67% Phase III randomized trial on-going : NCT01617161 Ongoing test

  50. Slide 50: Other development areas

    Slide 50: Other development areas

    Other development areas Breast Lung Pediatrics Increasing body of evidence PT could reduce treatment PT could reduce risk of showing results in terms of related pneumonitis and cardiac complications (*) IQ, growth related side allow to increase dose (**) effects, … (*) Ares et al Postoperative proto

  51. Slide 51: Potential of 2,000 – 5,000 rooms in 20 years

    Slide 51: Potential of 2,000 – 5,000 rooms in 20 years

    New scanning protocols increase patient potential Based on indications and Linac penetration Dutch Report 17.7% of RT Patients New Centers : More PBS New Protocols : More Indications New Trials: More Evidence Potential of 2,000 – 5,000 rooms in 20 years Only if clinical training is available - 53-

  52. Slide 52: A comprehensive PT clinical training

    Slide 52: A comprehensive PT clinical training

    A comprehensive PT clinical training Launched at ASTRO 2013, in partnership with Penn Medicine and Oncolink - 54

  53. Slide 53: Global overview with insight on US market

    Slide 53: Global overview with insight on US market

    GLOBAL OVERVIEW WITH insight on US MARKET Beth Klein, IBA VP US Sales

  54. Slide 54: Regional Segmentation aligned with Market Opportunity

    Slide 54: Regional Segmentation aligned with Market Opportunity

    Regional Segmentation aligned with Market Opportunity Focus Direct Sales and Marketing on USA and Select Western Europe countries In-direct Sales and Marketing on ROW United States Linacs Per Million Ireland Denmark Sweden Germany Norway Belgium Japan Netherlands Switzerland UK France S.Korea Greece

  55. Slide 55: Global adoption of IBA proton therapy

    Slide 55: Global adoption of IBA proton therapy

    Global adoption of IBA proton therapy 26 IBA reference centers - 25,000 patients treated - 57

  56. Slide 56: United States - Momentum building

    Slide 56: United States - Momentum building

    United States - Momentum building Unfavorable to PT Favorable to PT - PT Remains high profile investment - MediCare reimbursement rate back up - Slow economic recovery - Clinical Evidence is growing - Acceptable Care anxiety - Prostate less impactful in PT Mix - New indications Reimbursement Rates p

  57. Slide 57: Global Distribution of IBA Proton Therapy

    Slide 57: Global Distribution of IBA Proton Therapy

    Global Distribution of IBA Proton Therapy Mainly Direct Mainly Indirect Asia Americas Europe /MEA IBA leadership in China Direct augmented by Direct augmented by agents supporting network of partnerships with key with in-country credibility distributors/agents industry players - 59-

  58. Slide 58: Operating and under construction centers

    Slide 58: Operating and under construction centers

    Operating and under construction centers Operating & under construction IBA Varian Mevion Hitachi Protom - 60

  59. Slide 59: Proteus ONE is a commercial game-changer

    Slide 59: Proteus ONE is a commercial game-changer

    Proteus®ONE is a commercial game-changer A typical Sales Cycle Feasability Study CON Submission RFP Process ProteusPLUS Financing Contract Negotiation Construction Installation Ramp Up Smaller Investment ProteusONE Simple financing Significant Risk Faster Installation Reduction Fast ramp up - 61

  60. Slide 60: Commercial confidence

    Slide 60: Commercial confidence

    Commercial confidence North America Sales Requirements for Success  Pipeline Health: 10:3:1  Qualification discipline critical  Head quarter assist during cycle key differentiator Tactics  Bottoms up; proactive pipeline development  Strategic/National Account Focus  Aligned with Industry Partn

  61. Slide 61: Our Message: Unrivalled experience in proton therapy

    Slide 61: Our Message: Unrivalled experience in proton therapy

    Our Message: Unrivalled experience in proton therapy 25+ 25+ 25,000+ YEARS OF CENTERS SOLD PATIENTS TREATED EXPERIENCE • Ensures a strong integrated solution for its customers • Reliable and Stable equipment which provides for today’s needs and the future. • Resources within IBA ensure step by step

  62. Slide 62: Financials

    Slide 62: Financials

    FINANCIALS Olivier Legrain, IBA Chief Executive Officer Protect, Enhance, and Save Lives - 62 -

  63. Slide 63: Financial highlights 1H 2013

    Slide 63: Financial highlights 1H 2013

    Financial highlights 1H 2013 H1 2013 H1 2012 Variation (EUR 000) (EUR 000) (EUR 000) % Sales & Services 97 379 106 091 -8 712 -8.2% REBITDA 10.297 8 672 1 626 18.7% % of Sales 10.6% 8.2% REBIT 8 291 6 341 1 950 30.8% % of Sales 8.5% 6.0% Net Profit 4 129 -1 407 5 536 N/A % of Sales 4.2% -1.3%  Reve

  64. Slide 64: 1H 2013: Proton Therapy and Accelerators

    Slide 64: 1H 2013: Proton Therapy and Accelerators

    1H 2013: Proton Therapy and Accelerators H1 2013 H1 2012 Variance Variance (EUR 000) (EUR 000) (EUR 000) % Net Sales 74 962 82 110 -7 148 -8.7% - Proton Therapy 56 100 65 527 -9 427 -14.4% - Accelerators 18 862 16 583 2 279 13.7% REBITDA 6 900 4 436 2 464 55.5% % of Sales 9.2% 5.4% REBIT 5 196 2 534

  65. Slide 65: H1 2013: Dosimetry

    Slide 65: H1 2013: Dosimetry

    H1 2013: Dosimetry H1 2013 H1 2012 Variance Variance (EUR 000) (EUR 000) (EUR 000) % Net Sales 22 417 23 981 -1 564 -6.5% REBITDA 3 398 4 236 -838 -19.8% % of Sales 15.2% 17.7% REBIT 3 096 3 807 -711 -18.7% % of Sales 13.8% 15.9%  Sales impacted by slowdown in global radiotherapy market – only 1% p

  66. Slide 66: H1 2013: IBA Molecular

    Slide 66: H1 2013: IBA Molecular

    H1 2013: IBA Molecular  IBA Molecular distribution network (kept @ 40%):  Revenues still under pressure but stabilizing:  Strategic initiatives under way  Piramal’s new diagnostic imaging agent  Develop regional synergies  IBA New Compound Development (JV – 60%)  Business case under review: 

  67. Slide 67: Update on legacies & asset disposals

    Slide 67: Update on legacies & asset disposals

    Update on legacies & asset disposals  Essen  All LOI’s signed - Final signature of all documentation and closing by end of year  Operations and maintenance contract to begin upon closing  1st patient treated, 29th May  IBA Molecular  SK Capital confirmed EUR 20 million on c.EUR 24 million clai

  68. Slide 68: IBA net debt

    Slide 68: IBA net debt

    IBA net debt  Net debt of EUR 58.0 million including Trento of EUR 31.5 million. Pro forma since repayment announced today 26,5 million.  With acceptance of first Trento treatment room, outstanding amount paid this week  Post Trento repayment, final settlement of Essen and disposal of Bioassays,

  69. Slide 69: Guidance

    Slide 69: Guidance

    GUIDANCE Olivier Legrain, IBA Chief Executive Officer Protect, Enhance, and Save Lives - 69 -

  70. Slide 70: Guidance - high visibility on IBA's revenue

    Slide 70: Guidance - high visibility on IBA's revenue

    Guidance - high visibility on IBA’s revenue Based on:  High backlog level (EUR 211M) = high visibility over the next 12 to 24 months  Still expect to conclude approx. 8 PT rooms sales in 2013  Further penetration of compact system market expected especially in 2014 with the full FDA approval of P

  71. Slide 71: Guidance - high visibility on IBA's revenue

    Slide 71: Guidance - high visibility on IBA's revenue

    Guidance - high visibility on IBA’s revenue  IBA anticipates mid-single digit decrease in Group revenues in 2013  Confident of annual compound revenue growth of 5% to 10% over next three years and operational profit margin of 10% by end 2014  Efficiencies and restructuring initiatives expected to

  72. Slide 72: Summary

    Slide 72: Summary

    Summary  IBA re-positioned for growth, benefiting from increasing market adoption of proton therapy  Significant PT market growth potential driven by:  Growing adoption of PT internationally  Single room, compact PT system ProteusONE  PBS and broadening of PT cancer indications  Continued upta

  73. Slide 73: IBA best positioned in a game-changing market

    Slide 73: IBA best positioned in a game-changing market

    IBA best positioned in a game-changing market Clinical Advantage with PBS Affordable ProteusONE Leveraging Installed Base Protect, Enhance, and Save Lives - 73 -

  74. Slide 74: Thank you – Q&A

    Slide 74: Thank you – Q&A

    THANK YOU – Q&A Protect, Enhance, and Save Lives - 74 -

Source: Internet Archive copy of iba-worldwide.com

More decks from Ion Beam Applications SA

All 22 Ion Beam Applications SA decks