Slide 1: Southern Natural Gas Company 2018 Outage Review Meeting
Southern Natural Gas Company 2018 Outage Review Meeting Customer con call and Webex June 20, 2018 1
Slide 2: Welcome
Southern Natural Gas Company, L.L.C. Welcome
Slide 3: Agenda
Agenda • Review of current and upcoming notable Outages- – June/July/August • Unscheduled outages • North System • South System • South Louisiana • EEC 2018 • Contacts 3
Slide 4: Disclaimers
Disclaimers • Anticipated Impacts are estimates. Actual nominations, market demand, weather and pipeline conditions, etc. will determine if, and through what level, restrictions become necessary. • Unless otherwise stated, all scheduled dates represent gas days as defined in the Southern Natural Gas
Slide 5: Color Key for Maps
Color Key for Maps • Yellow – Restrictions are possible – With extended duration, restrictions could be necessary from time to time – Lower than normal pressures may be experienced – Meter(s) affected are noted with (PIN #) • Red – Restrictions are probable 5
Slide 6: Southern Natural Gas Pipeline
Southern Natural Gas Pipeline Chattanooga Rome Hartwell SC Muldon North System GA MS McConnells Tarrant Bell Mills Atlanta Aiken Pell City DeArmanville Louisville Wrens Providence Ocmulgee Pickens Reform Ellerslie Hall Gate Bear Creek Onward Auburn Thomaston Elba Rankin Selma Elmore Holy Trinity Bie
Slide 7: Unscheduled Outage Update
Southern Natural Gas Pipeline Unscheduled Outage Update Chattanooga Unscheduled unit Rome maintenance at Pickens Hartwell SC compressor station. Seg. 400 Muldon North System Bell Mills GA capacity of 234 Mdth/d impacted up to 70 Mdth/d MS McConnells Tarrant Atlanta Aiken Reform DeArmanville Providen
Slide 8: SNG North System Maint. Review June/July/August
SNG North System Maint. Review June/July/August Chattanooga Huntsville Rome AL Muldon Storage Atlanta Tarrant Bell Mills MS McConnells Pell City Reform DeArmanville Providence Louisville Pickens GA Onward Bear Creek Storage Maint. Pigging 20” AL Logansport Tuscaloosa Supply line Bienville Rankin 8-1
Slide 9: SNG South System Maint. Review June/July/August
SNG South System Maint. Review June/July/August MS Unit maintenance at Ocmulgee compressor Hartwell station 6-25-18 to 10-31-18 Aiken Atlanta Seg. 530 capacity of 804 Mdth/d impacted up to Wrens 109 Mdth/d GA Ocmulgee Hallgate AL Ellerslie Auburn Thomaston Elba Gallion Selma Elmore Unit Maint. Thoma
Slide 10: SNG South Louisiana System Maint. Review June/July/August
SNG South Louisiana System Maint. Review June/July/August Gwinville Pearl River MS LA Franklinton P/L Maint. WCFLL 5-1-18 to 9-15-18 Segment 350 capacity of 701 Mdth/d impacted up to 150 White Castle and Shadyside Mdth/d West Leg unit maintenance White Castle 4-1-18 to 10-31-18 Segment 340 capacity
Slide 11: SNG North System Maint. Review remainder of year
SNG North System Maint. Review remainder of year Chattanooga Hydro-test on 2ndNML Huntsville Bear Creek Shut-in test 10-1-18 to 10-31-18 Maintenance At Logansport Rome 10-16-18 to 9:00 am 10-23-18 Segment 130 capacity of 563 and Bienville stations DIQ and DWQ allocated 64% Mdth/d reduced up to 288 A
Slide 12: SNG South System Maint. Review Remainder of year
SNG South System Maint. Review Remainder of year MS Hartwell Aiken Atlanta Wrens P/L Maint. On Macon GA Branch line Ocmulgee 10-8-18 to 10-12-18 Hallgate Unit Maint. at Gallion Sta. 9-10-18 to 10-26-18 AL Ellerslie Seg. 460 capacity of 2,273 Auburn Thomaston Mdth/d impacted up to Elba 146 Mdth/d Gal
Slide 13: SNG South Louisiana System Maint. review Remainder of year
SNG South Louisiana System Maint. review Remainder of year Gwinville Pearl River MS LA Franklinton West Leg White Castle Toca P/L maintenance on the SS 28 East Leg line 9-10-18 to 10-01-18. SNG will not be able to accept Shadyside receipts Compressor Station Southern will be conducting other general
Slide 14: EEC line 2018
EEC line 2018 Chattanooga Rome Hartwell SC Muldon North System Bell Mills GA MS McConnells Tarrant Atlanta Aiken Reform DeArmanville Providence Pell City Hall Gate Wrens Louisville Ocmulgee Pickens Ellerslie Bear Creek Onward Auburn Thomaston Logansport Elba Rankin Bay Springs Selma Elmore Maint. pi
Slide 15: Gas Control Contacts
Gas Control Contacts • Gina Mabry – Manager (713) – 420 – 3685 (office) (281) – 744-8666 (cell) gina_mabry@kindermorgan.com • Kal Dankovich – Outage Coordinator (713) – 420 – 7522 (office) kalman_dankovich@kindermorgan.com • Jimmy Reese – Lead Controller (713) – 420 – 7310 (office) jimmy_reese@kinde
Slide 16: Questions?
j Southern Natural Gas Company, L.L.C. a Kinder Morgan Questions? 16