Slide 1: Exchange filing cover letter: Data Center Presentation
Anant Raj Lilllited CIN : L45400HR1985PLC021622 Head Off: H-65, Connaught Circus, New Delhi-110 001 Tel: 011-43034400, 23324127, 23323880, 43582879 E-mail: info@anantrajlimited.com Website: www.anantrajlimited.com Anant Raj Limited Regd. Office: CP-1, Sector-8, IMT Manesar, Haryana-122051 Tel: (0124
Slide 2: Strong Foundation, Stronger Future
Strong Foundation Stronger Future anantrajcloud.com
Slide 3: A Vision Turned Into Reality
A Vision Turned Into Reality Shri Ashok Sarin (Grandson of Shri. Rai Sahab Shadi Ram Sarin) started his Journey into the Construction & Development Business at a very early age. With the blessings of his parents Lala Anant Ram Sarin and Smt. Raj Kumari Sarin, established the Brand “Anant Raj” (named
Slide 4: Expansion into commercial property leasing and real estate verticals
Building on its well-established Construction Business, the Company ventured into leasing of Commercial Properties in prime areas of Delhi. The first property leased by the Company in the year 1978 which it still owns. The Company was fortunate enough not to need to sell any of its Commercial Proper
Slide 5: Why Data Center In India
Why Data Center In India India is witnessing robust growth in Data Center market, 01 based on an unprecedented surge in virtualization, cloud computing and public data generation. The market is expected to grow at 12% CAGR from 2019 to 2024 02 (Synergy Research Group), and cloud spending is expected
Slide 6: Favourable Political Climate with Planned Incentives
Favourable Political Climate with Planned ´Several Policy Growth Drivers for Data and Data Incentives Center in India, namely:- Digital India Initiative Data Protection & Localization Bill 2019 National E-Commerce Policy Aim to promote and incentivize Data Center and Updating of IT ACT Localized Dat
Slide 7: Advancements in Data Generation & Computing are driving growth
Advancements in Data Generation & Computing are Growth drivers for the Data Center market in India: driving growth Greater penetration of IoT Increase and widespread usage of Cloud Computing Massive transition from 2G/3G to 4G and Data Storage requirement to exceed 2000 MW IT subsequently 5G Load Ca
Slide 8: ARL Data Center: Upcoming Data Center Projects
ARL Data Center Upcoming Data Center Projects By ARL
Slide 9: Next Generation Development - Data Centre Manesar (Haryana)
Next Generation Development - Data Centre Manesar (Haryana) 01 Scale Capacity to develop to 300 MW of IT load Super Structure of 150 MW of IT Load ready 02 Efficiency Option of Standardized & Flexible designs Efficient PUE World Class Vendors & technology 03 Sustainability Energy-efficient building
Slide 10: Certifications
Certifications Indian Green Building Council (IGBC) hereby precertifies Anant Raj Cloud Pvt. Ltd., Data Center Manesar (IGBC Registration No: DC 21 018) The project has demonstrated an intent to design and build «a high performance Green Building in accordance with IGBC Green Data Center Rating Syst
Slide 11: Strategic Alliance with TCIL
Anant Raj Cloud Pvt. Ltd. (Wholly owned subsidiary of ARL) is proud to enter into a Strategic Alliance Partnership with TCIL (Telecommunications Consultants India Limited) , Govt. of India (PSU), for Data Centers. TCIL is a wholly owned Government of India undertaking & largest telecom engineering p
Slide 12: Business partner of RailTel
Anant Raj Cloud Pvt. Ltd. (Wholly owned subsidiary of ARL) is proud to be a business partner of RailTel, Govt. of India (PSU), for providing Data Center Services. RailTel is a Government of India undertaking & one of the largest neutral telecom infrastructure providers in the country.
Slide 13: Commenced Data Center at IMT Manesar
Commenced DATA Center at IMT Manesar Dedicated cabinets / exclusive secured cages/suites for ensuring data security Highly energy-efficient DCs with low PUE Carrier-neutral with 4 fibre path redundancy 2 HDAs/ floor -> High bandwidth connectivity N+N redundancy for UPS & telecom infrastructure (Tier
Slide 14: Schneider Racks & IT design by Cisco, CommScope
Schneider Racks (ER 6222) & IT design by CISCO, COMMSCOPE Fast deployment Fully assembled Key features for fast deployment APC solution compatibility Standardization Several heights, widths, depths for any IT Standardize on a single platform from edge to data center Base building block of data cente
Slide 15: HVAC - PAHUs & HSUs by Mitsubishi – Climaveneta
HVAC - PAHUs & HSUs (N+1) by Mitsubishi – Climaveneta Cooling with Hybrid system – Water cooled Chillers & Air Cooled Chillers (N+1) * For SERVER Room - “Precision Air Handling Units” of 50 Tr each with a N+1 Configuration CFD Analysis for Thermal * EC Fans for precision control scanning by simulati
Slide 16: Raised Access Floor Tiles with Provision for Services
Raised Access Floor Tiles with Provision for Services
Slide 17: Security Parameters for Data Center @ IMT Manesar
Security Parameter’s for DATA Center @ IMT Manesar Multiple Security Layers Property Boundary with Signage & Fencing. Secure Perimeter – Main Entry Gate, Overlapping Cameras, Building Access – Car Under Belly Check, Biometric, Access card and ID Baggage Scanners, DFMD, Hand held detectors. Data Secu
Slide 18: NOVEC Gas Suppression system & ELV system by Johnson Controls
NOVEC Gas Suppression system with Acoustic Nozzles & ELV system by JOHNSON Controls India JCI ELV services by JCI : •Access Control •CCTV •Rodent Repellant •VESDA •FA & PA System •WLD system
Slide 19: Actual Pictures of Server Hall & Services
Actual Pictures of Server Hall & Services
Slide 20: Actual Pictures of Server Hall & Services
Actual Pictures of Server Hall & Services
Slide 21: On Floor Electrical Panels & 500 KVA UPS
ON Floor Electrical Panels & 500 KVA UPS ( Schneider make) Power is being drawn From 2 sources through 2 different Shaft Paths, from the Existing Main Panels Fed to 2 UPS input Panels on the Floor Each Input panel is feeding to the UPS 1 & 2 This is fed into the 2 UPS Output panels Then to the PDUs
Slide 22: Lithium-ION Battery Bank at Data Centre Manesar
Lithium-ION BATTERY BANK AT DATA CENTRE MANESAR Longer Life 15 yrs. (Li-ion Batteries) vs 3 yrs. (for VRLA Batteries) Compact Size - Space required for Li-B is 65% lesser than VRLA Light Weight - Weight Reduction by 76% for Li-B as compared to VRLA batteries Monitoring system through BMS - easy Pred
Slide 23: Building Management System Room with Controlled System
Building Management System Room with Controlled System
Slide 24: Actual Pictures of Server Hall & Services
Actual Pictures of Server Hall & Services
Slide 25: Actual Pictures of Manesar Data Center
Actual Pictures of Manesar DATA CENTER
Slide 26: Data Center Development: Our Future Endeavours
Anant Raj Limited Data Center Development Our Future Endeavours
Slide 27: ARL Tech Park, Manesar-Haryana
ARL Tech Park Manesar-Haryana Area: 10 Acres Constructed Area: 1.8 Mill Sq. Ft Location: 10 Km from Gurugram – an IT/ITES and BPO Hub of NCR ( Anant Raj Tech Park,) Sector 8, IMT Manesar, Gurugram, Haryana 122051) Status: TIA-942 Tier III Certification received for 1st Phase 21 MW Data Center. 3 MW
Slide 28: ARL Trade Center, Rai-Haryana
ARL Trade Center Rai -Haryana Area: 25 acres Developable Area: 5.1 Mill Sq. Ft. Location: 5 km from NCR; Connected to Airport, Gurugram and Manesar by the operational KMP expressway (Anant Raj Tech Park, Plot No. TP-1, Near HSIIDC Ethnic City, Sector 38, Rai, Haryana 131029)) Constructed Building: 2
Slide 29: ARL Tech Park, Panchkula-Chandigarh
ARL Tech Park Panchkula- Chandigarh Area: 9.5 Acres Developable Area: 1.8 Mill Sq. Ft. Location: Anant Raj Tech Park, Plot no. 1 , Sector 22, Panchkula, Haryana 134109 Status: 0.6 Mill Sq. Ft. IT Building with Commercial Offices is operational Potential: 5.25 acres green field available with FSI of
Slide 30: Thankyou