DuPont de Nemours, Inc. · NYSE:DD

DuPont de Nemours — DuPont — Investor Presentation (August 2015)

36 slides from DuPont de Nemours's investor presentation, August 2015

  1. Slide 1: Tychem ThermoPro: 360° protection in 1 solution

    Tychem® ThermoPro 360o protection in 1 solution.

  2. Slide 2: Agenda

    AGENDA 1. Snapshot 2. Combined Chemical & FR protection 3. Offering you 360o protection 4. The applications 5. Zoom on the products 6. Chemical performance 7. Thermal performance 2

  3. Slide 3: Snapshot

    360° protection

  4. Slide 4: 360° Protection

    Snapshot 360o Protection When Chemical protection meets Heat, Flame & Arc protection 278g/m2 CAT III THERMAL & ARC // Type 3-B: EN 14605: 2005+A1:2009 CE flame & arc standards: // Type 4-B: EN 14605: 2005+A1:2009 // EN ISO 11612:2015 (Heat & flame) // Type 5-B: EN ISO 13982-1:2004 // Type 6-B: EN 13

  5. Slide 5: Combined Chemical & FR protection

    Combined Chemical & FR protection

  6. Slide 6: Multiple protection need against chemical & heat/flame

    Many users are facing the challenge of a multiple protection need against chemical & heat/flame hazards Question to type 3 users: Do you currently use Question to type 3 users: Any fire risk in addition to the high-end chemical protection coveralls which Chemical one? also have FR? Yes – high risk 2

  7. Slide 7: Typical Organic Chemicals & their flammability

    Typical Organic Chemicals & their flammability Inorganic Compounds Organic Compounds Hydrogen Sulfide Hydrocarbons Dry chemical Phenol Hydrogen Chloride Mercaptans Hydrochloric Acid Furfural Carbon Monoxide Glycol Sodium Hydroxide Butanone (MEK) Phosphoric Acid Amines Sodium Carbonates Polynuclear A

  8. Slide 8: FR & Thermal Performance

    An innovation at the junction of chemical & heat/flame protection Long Duration Structural CRFR solution Thermal Exposure Firefighting Gear Flash fire Escape Nomex® IIIA Clothing* FR & Thermal Performance Does Not Ignite Slow Burn, FR - PVC Self-Extinguish Rainwear Stop, Drop & Roll Chemical Barrier

  9. Slide 9: Offering you 360° protection

    Offering you 360°protection

  10. Slide 10: The fabric

    The fabric Inside: Outside: Nomex® Tychem® nonwoven barrier 360o protection Latest innovation combining into 1 single garment 2 unique DuPont technologies: NOMEX® & TYCHEM®

  11. Slide 11: 360° peace of mind

    360o peace of mind Tychem® ThermoPro brings you:  360o Peace of mind (2 highest protection into 1 solution)  Practicality & Comfort (no need to combine 2 coveralls anymore) Nomex in a heat application as it would have a dual purpose then. Chemical as well as fire protection

  12. Slide 12: The applications

    The applications

  13. Slide 13: Facing the challenge of a dual protection need

    Facing the challenge of a dual protection need against chemical & heat/flame OIL AND GAS / UNIVERSITY LABS PETCHEM FFIGHTERS / LAW ENFORCEMENT ER TEAMS SEMI-CONDUCTOR MFG 13 Flammable liquids / chemicals / solvents - Electrostatic risk - Powder / dust explosion - Sparks / welding

  14. Slide 14: Tychem ThermoPro in the Oil & Gas application

    Tychem® ThermoPro in the Oil & Gas application IN CRUDE OIL DISTILLATION (FRACTIONATION) Even though these are closed processes, heaters and exchangers in the atmospheric and vacuum distillation units could provide a source of ignition, and the potential for a fire exists should a leak or release oc

  15. Slide 15: Tychem ThermoPro in the Oil & Gas application

    1. Tychem® ThermoPro in the Oil & Gas application IN ALTERATION PROCESS The potential for a fire exists should a release of reformate gas or hydrogen occur or leak contact a source of ignition such as the heater. In March 2005 several explosions and a fire occurred during the startup of the isomeriz

  16. Slide 16: Tychem ThermoPro in the Oil & Gas application

    1. Tychem® ThermoPro in the Oil & Gas application OTHER REFINERY OPERATIONS Other Operations consist of Heat Exchangers, Coolers, Process Heaters, steam generators, Pressure-Relief and Flare Systems, Wastewater Treatment, Cooling Towers, Gas and Air Compressors, Marine, Tank Car, and Tank Truck Load

  17. Slide 17: Laboratories

    2. Laboratories Laboratory workers with potential exposure to flammable liquid splash and ignition hazards (flammable & toxic dust) • Industrial and academic • All company personnel and contractors • Protection of workers/students • flammable chemicals • pyrophoric (spontaneous combustion) chemical

  18. Slide 18: University Lab Explosion (Germany)

    University Lab in Explosion (Germany), 16 injured and 10 000 € damages (16.1.14) Organic chemistry research lab experiment : - 24 year old student - Potassium Nitrate (often used in fertilizer or gun powder production) and sulphuric acid 18 - 16 injured (glass splinters and gas inhalation) in the ex

  19. Slide 19: Law enforcement

    3. Law enforcement Law Enforcement dealing with of illegal Chemical Operations Why? • Criminals do not obey worker safety and environmental laws • Environments often involve highly flammable chemicals, stored incorrectly/together with a probability of fire flash over • Chemical organic compounds Ope

  20. Slide 20: Semi-conductor fabrication

    4. Semi-conductor fabrication Young industry (30 yrs) experiencing exponential growth. However at the expense of process-related fires that have caused devastating property damage, production interruption and loss of market share Combination of a highly sophisticated and vulnerable production proces

  21. Slide 21: Ammonium Nitrate Disasters – Fertilizer Plants

    5. Ammonium Nitrate Disasters – Fertilizer Plants > 20 major incidents since 1921 Source: Wikipedia 21

  22. Slide 22: Firefighters / ER teams

    6. Firefighters / ER teams • To protect others, emergency responders need the best protection for themselves. Whether responding to a traffic accident or containing an industrial emergency, responders need a garment that will protect them from many hazards. • Nomex® , the name firefighters have valu

  23. Slide 23: The products

    DuPont Tychem ThermoPro

  24. Slide 24: Tychem ThermoPro range

    Tychem® ThermoPro range FULL PROTECTION FULL PROTECTION PARTIAL PROTECTION FLEXIBILITY WITH 2 PIECE FRONTAL EXPOSURE Coverall Bib Overall & Jacket Combo Gown TP 198T OR TP 750T OR TP 275T OR 24

  25. Slide 25: Tychem ThermoPro Coverall - TP 198T OR

    Tychem® ThermoPro Coverall - TP 198T OR Category III, Type 3B,4,5,6 • Taped seams provide strong chemical resistance against heavy liquid splashes. A sewn seam is covered with a strip of compatible chemical- resistant material through heat sealing. • Attached respirator-fit hood with drawstring to p

  26. Slide 26: Tychem ThermoPro Bib Overall & Jacket Combo - TP 750T OR

    Tychem® ThermoPro Bib Overall & Jacket Combo - TP 750T OR Category III, Type 3B,4,5,6 • Jacket and bib overall combination ensemble. Jacket and bib overall not sold separately. • Sewn with Nomex® thread • All garment components are flame resistant and thermally stable • Garment developed to meet the

  27. Slide 27: Tychem ThermoPro Gown - TP 275T OR

    Tychem® ThermoPro Gown - TP 275T OR Category III, Partial Body type 3 • Provides frontal protection • For flash fire and electric arc hazards, partial body protective Tychem® ThermoPro garments must be used in conjunction with primary flame resistant clothing that is rated for the fire/arc hazard. •

  28. Slide 28: Considerations for Complimentary Compatible PPE

    Considerations for Complimentary Compatible PPE  Flash-fire tested, full-face respirators  Flash-fire tested gloves  Foot and head protection 28

  29. Slide 29: The Chemical performance

    The Chemical performance

  30. Slide 30: Protects against organic chemicals

    • Chemical Permeation: Tested against >260 chemicals • Permeation Barrier against organic chemicals (as for Tychem® F) • All available on SafeSpec Protects against organic chemicals 30

  31. Slide 31: The Thermal protection

    The Thermal protection

  32. Slide 32: Thermo-Man Instrumented Manikin

    Thermo-Man® Instrumented Manikin To assess flash fire performance of garment systems in flash fire environments  Developed in 70’s by U.S. Military & DuPont  ASTM F 1930 Method  Three Facilities in North America  DuPont (UL Certified)  N.C. State University (UL Certified)  University of Albert

  33. Slide 33: Thermal Hazard Science

    Thermal Hazard Science Realistic Flash Fire Exposure Conditions • Controllable Heat Flux and Exposure Time • Reflects Actual Industrial Exposures Full Size Instrumented Manikin • With > 100 Sensors Sensors Measure Heat Transfer • Through Test Garment(s) Total Body Area, Degree, and Location of Predi

  34. Slide 34: Nomex: your safest choice

    Nomex®: your safest choice Most Flash Fire Exposures Will Cause Burn Injury to Exposed Skin And Ignite Flammable Clothing

  35. Slide 35: ThermoPro results on Thermo-Man

    ThermoPro results on Thermo-Man® Results of the Tychem® ThermoPro on the Thermo-Man® are outstanding (from 6.6% down to 0% body burns after 4 sec exposure) Thermo-Man 4s results (NO 3rd degree burns) 35

  36. Slide 36: 360° protection

    360° protection UPON Tychem > DuPont™ Tychem® ThermoPro SINGLE LAYER, TRIPLE PROTECTION

DuPont — Investor Presentation (August 2015) on 6ix