  1. Slide 1: Heat Exchanger Library Overview

    Slide 1: Heat Exchanger Library Overview

    HEAT EXCHANGER LIBRARY Overview ©2021 Modelon.

  2. Slide 2: Agenda

    Slide 2: Agenda

    AGENDA ❑ About Heat Exchanger Library ❑ Key Features ❑ Key Capabilities ❑ Key Applications ❑ Library Contents ❑ Modelon Compatibility ❑ Latest Release ©2021 Modelon. 2

  3. Slide 3: About Heat Exchanger Library

    Slide 3: About Heat Exchanger Library

    ABOUT HEAT EXCHANGER LIBRARY • Modelica library by Modelon • Geometric, segmented heat exchanger models • Several flat tube and louvered fin designs • Plate heat exchangers with plain plates, Chevron or louvered fins • Inhomogeneous flow and temperature distribution • Heat exchanger stacking • Coupl

  4. Slide 4: Key Benefits

    Slide 4: Key Benefits

    KEY BENEFITS ©2021 Modelon. 4

  5. Slide 5: Key Benefits

    Slide 5: Key Benefits

    KEY BENEFITS • Geometric models of flat tube and plate heat exchangers • Geometric friction and heat transfer correlations • Air side interface allows heat exchanger stacking • Automatic area fraction calculations on flow segment level • 2D – discretized and lumped flow source and sensor components

  6. Slide 6: Key Capabilities

    Slide 6: Key Capabilities

    KEY CAPABILITIES ©2021 Modelon. 6

  7. Slide 7: Key Capabilities

    Slide 7: Key Capabilities

    KEY CAPABILITIES • Detailed geometric models of flat tube and plate heat exchangers • Geometric friction and heat transfer correlations • Air models with humidity allows for condensation modeling • Orientation of flow paths in 3D, 2D resolution of inlet and outlet air conditions. • Templates for sta

  8. Slide 8: Key Applications

    Slide 8: Key Applications

    KEY APPLICATIONS ©2021 Modelon. 8

  9. Slide 9: Key Applications

    Slide 9: Key Applications

    KEY APPLICATIONS • Stacking • Cross Flow Flattube HeatExchanger • Plate HeatExchanger 2018-08-08 ©2021 Modelon. 9

  10. Slide 10: Example: Four Heat Exchangers, Two Fans and One Bar Obstacle in Air Flow

    Slide 10: Example: Four Heat Exchangers, Two Fans and One Bar Obstacle in Air Flow

    EXAMPLE: FOUR HEAT EXCHANGERS, TWO FANS AND ONE BAR OBSTACLE IN AIR FLOW The stack is set up from a template by specifying dimensions and used in this test model. The different colors describe different fluids: Blue: Incompressible liquid, Green: Two-phase fluid, Orange: Gas. Light blue and grey are

  11. Slide 11: Example: Cross Flow Flattube

    Slide 11: Example: Cross Flow Flattube

    EXAMPLE: CROSS FLOW FLATTUBE • Cross-flow • Atmospheric air – inhomogeneous air inlet possible • Liquid, two-phase and gas medium on secondary side • Geometric friction and heat transfer correlations ©2021 Modelon. 11

  12. Slide 12: Example: Plate Heat Exchanger

    Slide 12: Example: Plate Heat Exchanger

    EXAMPLE: PLATE HEATEXCHANGER This experiment is for a liquid - two phase plate heat exchanger with plain plates and counter-current flow. The visualizer under the heat exchanger reports the heat flow between the liquid and two phase flow. The visualizer above the heat exchanger shows the general tem

  13. Slide 13: Library Contents

    Slide 13: Library Contents

    LIBRARY CONTENTS ©2021 Modelon. 13

  14. Slide 14: Library Contents

    Slide 14: Library Contents

    LIBRARY CONTENTS • HeatExchangers • Stacks • FlowSegmentation • Media • Sources and Sensors ©2021 Modelon. 14

  15. Slide 15: Library Contents: HeatExchangers

    Slide 15: Library Contents: HeatExchangers

    LIBRARY CONTENTS HeatExchangers There are two subsections of heat exchanger models: 1. Flat tubes 2. Plate Modeling Approach Horizontal • Geometries considered Coolant Segmentation Coolant path discretization: Unique temperature exposed to the wall in each segment. Several segments per pass and mult

  16. Slide 16: Library Contents: FlatTube HeatExchanger

    Slide 16: Library Contents: FlatTube HeatExchanger

    LIBRARY CONTENTS FlatTube HeatExchanger Vertical Horizontal • Cross flow • Liquid / two-phase – air (condensing) Microchannel flattube – louvered or offset strip fins • Gas – air, fins – fins • Liquid – air, fin – fin ©2021 Modelon. 16

  17. Slide 17: FlatTube HeatExchanger Channel Geometries

    Slide 17: FlatTube HeatExchanger Channel Geometries

    LIBRARY CONTENTS FlatTube HeatExchanger Channel geometries Several geometries are possible. • Free flow area, heat transfer area, etc. calculated automatically • Geometric friction and heat transfer correlations included Air Side Interface • The air flow through each segment assumes uniform flow and

  18. Slide 18: FlatTube HeatExchanger

    Slide 18: FlatTube HeatExchanger

    LIBRARY CONTENTS FlatTube HeatExchanger 1 1. External connector: Flow segmented by stream tubes, high resolution temperature profile, full stream field represented (not limited by HX outer edges) 2. Replaceable components 2 3 3. Discretized wall • Supports multiple layers. Arbitrary pass ordering •

  19. Slide 19: Plate HeatExchanger

    Slide 19: Plate HeatExchanger

    LIBRARY CONTENTS Plate HeatExchanger • Co- / counter-flow • Plate heat exchangers, plain & Chevron any combination of liquid, gas and two phase fluid • Plate – fin and fin – fin for gas and liquid • Any combination of local co- / counter flow arrangements and different number of passes allowed ©2021

  20. Slide 20: Plate Flow Scheme

    Slide 20: Plate Flow Scheme

    LIBRARY CONTENTS Plate Flow Scheme • The flow scheme is defined as arrays: • Passes_A = {2,2,2,2} • Passes_B = {4,4} Counter flow • Total number of channels for A and B must be equal Cocurrent flow ©2021 Modelon. 20

  21. Slide 21: Plate HeatExchanger

    Slide 21: Plate HeatExchanger

    LIBRARY CONTENTS Plate HeatExchanger • Plates with counter flow or concurrent flow • Often uses pressurized media • Plain or Chevron plate surfaces 1. Replaceable components 2. Discretized wall 2 1 ©2021 Modelon. 21

  22. Slide 22: Stack

    Slide 22: Stack

    LIBRARY CONTENTS Stack • In the Stacks package, there are different templates and experiments describing multiple different setups. This allows the user to get a better understanding of how to use the Stack components. ©2021 Modelon. 22

  23. Slide 23: Stream Tubes

    Slide 23: Stream Tubes

    LIBRARY CONTENTS Stream Tubes • For stack models, stream tubes concept is introduced along air flow. The segment edges are aligned with the heat exchanger components boundaries and depend on component size and position only. • A given number of additional points can be added in the largest gaps. • F

  24. Slide 24: Stream Tubes

    Slide 24: Stream Tubes

    LIBRARY CONTENTS Stream Tubes • Stream tube grid point are automatically added at component boundaries, and a given number of additional points can be added in the largest gaps. • The blue and red color indicates the additional grid points in y and z directions ©2021 Modelon. 24

  25. Slide 25: Stack

    Slide 25: Stack

    LIBRARY CONTENTS Stack • Example: Two heat exchangers without common edges. Partly covered by an obstacle causing lower flow rate through a segment. • Air flow straight through the heat exchanger stack is assumed. • The stack can now be built by directly connecting components. The component connecto

  26. Slide 26: Media and other basic components

    Slide 26: Media and other basic components

    LIBRARY CONTENTS Media and other basic components ©2021 Modelon. 26

  27. Slide 27: Modelon Compatibility

    Slide 27: Modelon Compatibility

    MODELON COMPATIBILITY ©2021 Modelon. 27

  28. Slide 28: Recommended Modelon Library Compatibility

    Slide 28: Recommended Modelon Library Compatibility

    RECOMMENDED MODELON LIBRARY COMPATIBILITY • HeatExchanger Library components are seamless compatible with Liquid cooling Library, VaporCycle Library, Engine Dynamics Library. • HeatExchanger Library compatible with Batch simulation in • MATLAB • Python • Excel ©2021 Modelon. 28

  29. Slide 29: Example: Batch Simulation in FMI Add-in for Excel

    Slide 29: Example: Batch Simulation in FMI Add-in for Excel

    EXAMPLE : BATCH SIMULATION IN FMI ADD-IN FOR EXCEL Experiment settings • Monte Carlo on the HX effectiveness multipliers (uniform distribution Parameter modifiers between 0.6 & 1) and the flow rate scaling factors (normal distribution with mean 1 and std dev 0.1) • Constant Speed drive cycle at 120

  30. Slide 30: Latest Release

    Slide 30: Latest Release

    LATEST RELEASE ©2021 Modelon. 30

  31. Slide 31: Release 2021.2 New Features and Enhancements

    Slide 31: Release 2021.2 New Features and Enhancements

    RELEASE: 2021.2 New Features • Two new two-phase-two-phase counter-flow heat exchangers with a plain plate/chevron surface developed Enhancements • Plate heat exchanger geometry records descriptions improved • The model components (HX, source blocks, correlations, geometry) of the flat tube and plat