DuPont de Nemours, Inc. · NYSE:DD

DuPont de Nemours — DuPont — Technical Presentation (2013)

55 slides from DuPont de Nemours's technical presentation, 2013

  1. Slide 1: The 3 Second Myth: FR Compliance vs Protection

    THE 3 SECOND MYTH FR Compliance vs Protection 1 Copyright© 2013 E.I. du Pont de Nemours and Company. “ This material is only intended for this (webinar) and may not be used for any other purpose without the expressed written consent of DuPont”

  2. Slide 2: Agenda

    AGENDA Industrial fires and standards Why the focus on “flash fires” Where did the 3 second duration come from How FR fabrics work Why exposure duration matters Why exposure intensity matters Testing your FR garments DuPontTM Nomex(R) is a registered trademark of E.I. duPont de Nemours & Company, In

  3. Slide 3: What You Should Know About Industrial Fires and Standards

    WHAT YOU SHOULD KNOW ABOUT INDUSTRIAL FIRES AND STANDARDS 3 Copyright© 2013 E.I. du Pont de Nemours and Company. “ This material is only intended for this (webinar) and may not be used for any other purpose without the expressed written consent of DuPont”

  4. Slide 4: Industrial Fire and Standard Misconceptions

    INDUSTRIAL FIRE AND STANDARD MISCONCEPTIONS Industry misconceptions may influence FR clothing selection The purpose of flame resistant clothing is to only protect workers from Flash Fire Hazards All, or most, fire hazards:  Are short duration (3 seconds or less)  Have the same intensity (2 cal/cm2

  5. Slide 5: What Are Industrial Fires?

    WHAT ARE INDUSTRIAL FIRES? Types and Sources of Industrial Fires Flash - Rapid Burning of Vapor Cloud Fuel Sources Jet - Burning of Pressurized Fuel Supply  Flammable Liquids Pool - Burning of Flammable Liquid Spill  Flammable Gases BLEVE - Explosion & Fireball from Catastrophic Failure of Contain

  6. Slide 6: What Are Typical Industrial Fires?

    WHAT ARE TYPICAL INDUSTRIAL “FIRES”? There are no “typical” industrial fires Three (3) Main Variables (Duration X Intensity = Magnitude)  Duration (Exposure Time, seconds) - 1 sec to “Time to Escape”  Intensity (Heat Flux) - <1 to >7 cal/cm2s”  Magnitude (Total Exposure Energy) - <1 to >20 cal/cm

  7. Slide 7: Industrial Fires: Recent Industrial Incidents

    INDUSTRIAL FIRES Recent Industrial Incidents May 4, 2009 Routine Excavation Veolia Environmental Services Gas Line Ruptured West Carrollton, OH Operator & Rig Engulfed Flammable Release from Waste Recycling Process to Atmosphere 2 Workers Seriously Injured 20 Residences Damaged 7 Copyright© 2013 E.I

  8. Slide 8: Industrial Fires: Recent Incidents, Chemical Safety Board

    INDUSTRIAL FIRES Recent Industrial Incidents – Refer to Chemical Safety Board July 19, 2009 Citgo HF Plant – Surveillance Camera Corpus Christi, TX Vapor Cloud + Jet Fire October 6, 2005 Formosa Plastics Point Comfort, TX Propylene Explosion 8 Copyright© 2013 E.I. du Pont de Nemours and Company. “ T

  9. Slide 9: Safety and Health Program: PPE Is the Last Line of Defense

    SAFETY AND HEALTH PROGRAM PPE is the last line of defense Personal Protective Equipment 4. PPE 3. Work Practices Proper Tools Clothing Proper Procedures Eye Protection Foot Protection Head Protection 2. Engineering Technical solutions Hand Protection to make equipment safer Hearing Protection Respir

  10. Slide 10: Employer Responsibilities – PPE Requirements

    EMPLOYER RESPONSIBILITIES – PPE REQUIREMENTS OSHA 29 CFR 1910.132 Personal Protective Equipment for General Industry (d)(1) The employer shall assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE). If s

  11. Slide 11: General PPE Requirements for Employer

    GENERAL PPE REQUIREMENTS FOR EMPLOYER OSHA 3151 – Personal Protective Equipment Guide Perform a Hazard Assessment of the Workplace Identify & Control Physical and Health Hazards Identify & Provide Appropriate PPE for Employees  OSHA 3151-12R 2003, “…select PPE that will provide a level of protectio

  12. Slide 12: Consensus Standards – Minimum Material Performance

    CONSENSUS STANDARDS – MINIMUM MATERIAL PERFORMANCE NFPA 2112: Standard on Flame Resistant Garments for Protection of Industrial Personnel Against Flash Fire Provides Minimum Requirements for FR Garments  Design  Construction  Evaluation  Certification Primarily for Manufacturers, not End-Users R

  13. Slide 13: Consensus Standards – Selection, Care, & Use

    CONSENSUS STANDARDS – SELECTION, CARE, & USE NFPA 2113: Standard on Selection, Care, Use, and Maintenance of Flame Resistant Garments for Protection of Industrial Personnel Against Flash Fire OSHA Recognized Tool for 29 CFR 1910.132 Perform Fire / Exposure Hazard Assessment Primarily for End-Users P

  14. Slide 14: Industry Focuses on Flash Fires... Why?

    INDUSTRY FOCUSES ON “FLASH FIRES”……WHY? 14 Copyright© 2013 E.I. du Pont de Nemours and Company. “ This material is only intended for this (webinar) and may not be used for any other purpose without the expressed written consent of DuPont”

  15. Slide 15: What Is a Flash Fire?

    WHAT IS A FLASH FIRE? Flash Fire: A non-explosive combustion of a vapor cloud from a release of flammable material into the open air Its duration, intensity, and magnitude depend on many factors Flammable gas generation rate (discharge rate) Total vapor cloud mass released (prior to ignition) Disper

  16. Slide 16: Why Focus on Flash Fire? Historical Reference

    WHY FOCUS ON FLASH FIRE? Common industry term when standards developed HISTORICAL REFERENCE “Flash Fire” was a common industry term used for fire events when the NFPA & CGSB standards were first developed in 2000. NFPA 2112 NFPA 2113 CGSB 155.20 16 Copyright© 2013 E.I. du Pont de Nemours and Company

  17. Slide 17: Why Focus on Flash Fire? Standard Evolution

    WHY FOCUS ON FLASH FIRE? NFPA 2112 and 2113 standard evolution NFPA 2112 & 2113 have been moving towards recognizing all fire/thermal hazards not just flash fires The wording in the standards purpose statement has added the term “short duration thermal exposure” NFPA 2112 – 2012, 1.2.1* This standar

  18. Slide 18: The Origin of 3 Seconds

    THE ORIGIN OF 3 SECONDS 18 Copyright© 2013 E.I. du Pont de Nemours and Company. “ This material is only intended for this (webinar) and may not be used for any other purpose without the expressed written consent of DuPont”

  19. Slide 19: The 3 Second Misconception

    THE “3 SECOND” MISCONCEPTION Why the industry thinks workers only need protection for 3 seconds? Early editions of NFPA 2113 described a flash fire as typically lasting 3 seconds in the appendix, this has since been removed  The OSHA 2010 memo to the Oil & Gas market indicated flash fires can last

  20. Slide 20: Aren't All Flash Fires 3 Seconds or Less?

    AREN’T ALL “FLASH” FIRES 3 SECONDS OR LESS? Actually, no (and flash fire is not defined this way per NFPA) 3.3.13* Flash Fire. A fire that spreads by means of a flame front rapidly through a diffuse fuel, such as dust, gas, or the vapor of an ignitable liquid, without the production of damaging pres

  21. Slide 21: Where Did 3 Seconds Originate?

    WHERE DID 3 SECONDS ORIGINATE? Testing helicopter pilot flight suit materials for the military 1970’s - U.S. military ran a test to determine total heat exposure received by pilots escaping through the burning fuel of a helicopter crash  Sensored and clothed manikin was pulled through burning pool

  22. Slide 22: Why Is 3 Seconds Used in the Manikin Test?

    WHY IS 3 SECONDS USED IN THE MANIKIN TEST? Standardized test method to reach minimum 6 cal/cm² protection value DuPont developed the manikin test to provide a repeatable test method that can easily and safely generate 6 cal/cm² total energy exposure needed by the military  Propane is a common, easi

  23. Slide 23: Flash Fire Duration Misconception

    “FLASH” FIRE DURATION MISCONCEPTION Consider Research Conducted by the U.S. Department of Energy1 In the graph of these tests, burn times reached more than 15 sec.  Highlights the need to understand the hazard The Fire Protection Engineering handbook has vapor cloud fire models2  Various flammable

  24. Slide 24: Flash Fire Intensity Misconception

    “FLASH” FIRE INTENSITY MISCONCEPTION All “Flash” fires are 2 cal/cm²s -> the intensity used in the NFPA 2112 thermal manikin test Experimental data1,3 has shown potential for significantly higher values DOE China Lake Experiments with Liquid Natural Gas Vapor Cloud Fires  Measured peak heat flux va

  25. Slide 25: How Flame-Resistant Fabrics Work: All FR Is Not Created Equal

    HOW FLAME-RESISTANT FABRICS WORK ALL FR IS NOT CREATED EQUAL 25 Copyright© 2013 E.I. du Pont de Nemours and Company. “ This material is only intended for this (webinar) and may not be used for any other purpose without the expressed written consent of DuPont”

  26. Slide 26: Purpose of Flame Resistant (FR) Fabrics

    PURPOSE OF FLAME RESISTANT (FR) FABRICS Reduce Burn Injury and Increase Chance of Survival Does Not Ignite and Continue to Burn Does Not Melt and Drip Maintains a Barrier Insulates the Wearer from Heat Resists Breaking Open Provides Valuable Escape Time However, Burn Injuries Can Occur In Spite Of T

  27. Slide 27: Types of Flame Resistant (FR) Fabrics

    TYPES OF FLAME RESISTANT (FR) FABRICS Not All FR Is Made The Same Inherent (e.g. Nomex®, Kevlar®, PBI®, Kermel®, etc) FR performance is present in the DNA / chemistry of the fiber at the time of production Fiber molecular structure does not support combustion Inherent Blends (e.g. Nomex® MHP , Tecas

  28. Slide 28: Nomex – Proven Performance

    NOMEX® - PROVEN PERFORMANCE Hazards are Unpredictable. Nomex® is Not. Heritage: 40 years of proven performance 40+ years of the best thermal protection Inherent flame-resistant protection Protection from heat & flame, arc, and welding Inherent (Not Treated) lightweight protection Lightweight single

  29. Slide 29: Why Does Exposure Duration Matter?

    WHY DOES EXPOSURE DURATION MATTER? 29 Copyright© 2013 E.I. du Pont de Nemours and Company. “ This material is only intended for this (webinar) and may not be used for any other purpose without the expressed written consent of DuPont”

  30. Slide 30: Duration Is a Variable of Total Exposure

    DURATION IS A VARIABLE OF TOTAL EXPOSURE You can generate total exposure by changing duration Heat Flux / Intensity Total Exposure Duration (sec) X (cal/cm²s) = (cal/cm²) 2.5 2.0 5.0 NFPA 3.0 2.0 6.0 2112 3.5 2.0 7.0 4.0 2.0 8.0 Total Exposure Energy = Duration X Intensity 7 oz/sy FR Treated Cotton

  31. Slide 31: Duration & Intensity Impact Predicted Body Burn Injury %

    DURATION & INTENSITY IMPACT PREDICTED BODY BURN INJURY % You can generate total exposure by changing duration or intensity NOMEX® IIIA - 6 oz/yd2 88/12 FR Treated Cotton / Nylon – 7 oz/yd2 3 seconds @ 2.02 cal/cm2s 3 seconds @ 2.02 cal/cm2s Total Exposure: 6.06 cal/cm2 Total Exposure: 6.06 cal/cm2 1

  32. Slide 32: Duration & Intensity Impact Predicted Body Burn Injury %

    DURATION & INTENSITY IMPACT PREDICTED BODY BURN INJURY % You can generate total exposure by changing duration or intensity 32 Copyright© 2013 E.I. du Pont de Nemours and Company. “ This material is only intended for this (webinar) and may not be used for any other purpose without the expressed writt

  33. Slide 33: Impact of Hazard & Apparel Selection on Survivability

    IMPACT OF HAZARD & APPAREL SELECTION ON SURVIVABILITY At NFPA 2112 conditions – Less variation in FR fabric performance EXAMPLE Total Exposure Energy: 6 cal/cm2 88/12 FRTC (7 oz) 12 99.5 Testing conditions: (ASTM F1930)  Intensity: 2 cal/cm2sec 4% variance  Duration: 3 seconds Nomex® (6 oz) 16 99

  34. Slide 34: Duration and Predicted Body Burn Injury %

    DURATION AND PREDICTED BODY BURN INJURY % You can generate total exposure by changing duration NOMEX® IIIA - 6 oz/yd2 88/12 FR Treated Cotton / Nylon – 7 oz/yd2 4 seconds @ 2.06 cal/cm2s 4 seconds @ 2.06 cal/cm2s Total Exposure: 8.24 cal/cm2 Total Exposure: 8.24 cal/cm2 43.4% Predicted Body Burn Inj

  35. Slide 35: Duration and Predicted Body Burn Injury %

    DURATION AND PREDICTED BODY BURN INJURY % You can generate total exposure by changing duration 35 Copyright© 2013 E.I. du Pont de Nemours and Company. “ This material is only intended for this (webinar) and may not be used for any other purpose without the expressed written consent of DuPont”

  36. Slide 36: Predicted Body Burn Injury % at Increased Duration

    PREDICTED BODY BURN INJURY % AT INCREASED DURATION NOMEX® IIIA, 6 oz/yd2  4 seconds @ 2.06 cal/cm2s  Total Exposure: 8.24 cal/cm2  Predicted Burn Injury: 43.4% 88/12 FR Treated Cotton / Nylon, 7 oz/yd2  4 seconds @ 2.06 cal/cm2s  Total Exposure: 8.24 cal/cm2  Predicted Burn Injury: 77.9% 36 Co

  37. Slide 37: Impact of Hazard & Apparel Selection on Survivability

    IMPACT OF HAZARD & APPAREL SELECTION ON SURVIVABILITY Your chance of surviving doubles with garments made of Nomex® EXAMPLE Total Exposure Energy: 8 cal/cm2 88/12 FRTC (7 oz) 42 78 Testing conditions:  Intensity: 2 cal/cm2s 35% variance  Duration: 4 seconds Nomex® (6 oz) 43 91 Body burns vary by 3

  38. Slide 38: Total Heat Exposure From Industrial Fires Can Be Variable

    TOTAL HEAT EXPOSURE FROM INDUSTRIAL FIRES CAN BE…… Real world fires (flash fire or other) 6 cal/cm2 Exposure (per NFPA 2112)  Body burns 12 – 16%  Survivability 99% + Regardless of FR fabric type 8 cal/cm2 Exposure  Body burns 43 – 78%  Survivability 42 – 91% Depends on FR fabric type NFPA 2112

  39. Slide 39: Why Does Exposure Intensity Matter?

    WHY DOES EXPOSURE INTENSITY MATTER? 39 Copyright© 2013 E.I. du Pont de Nemours and Company. “ This material is only intended for this (webinar) and may not be used for any other purpose without the expressed written consent of DuPont”

  40. Slide 40: Intensity Is a Variable of Total Exposure

    INTENSITY IS A VARIABLE OF TOTAL EXPOSURE You can generate total exposure by changing duration or intensity Heat Flux / Intensity Total Exposure Duration (sec) X (cal/cm²s) = (cal/cm²) 3.0 1.75 5.25 NFPA 3.0 2.0 6.0 2112 3.0 2.33 7.0 3.0 2.67 8.0 Total Exposure Energy = Duration X Intensity 7 oz/sy

  41. Slide 41: Intensity and Predicted Body Burn Injury %

    INTENSITY AND PREDICTED BODY BURN INJURY % FR Treated Cotton at 3 seconds with varying intensity 88/12 FR Treated Cotton / Nylon – 7 oz/yd2 88/12 FR Treated Cotton / Nylon – 7 oz/yd2 3 seconds @ 2.02 cal/cm2s 3 seconds @ 2.36 cal/cm2s Total Exposure: 6.06 cal/cm2 Total Exposure: 7.08 cal/cm2 11.5% P

  42. Slide 42: Intensity and Predicted Body Burn Injury %

    INTENSITY AND PREDICTED BODY BURN INJURY % FR Treated Cotton at 3 seconds with varying intensity 42 Copyright© 2013 E.I. du Pont de Nemours and Company. “ This material is only intended for this (webinar) and may not be used for any other purpose without the expressed written consent of DuPont”

  43. Slide 43: Intensity and Predicted Body Burn Injury %

    INTENSITY AND PREDICTED BODY BURN INJURY % NOMEX® IIIA at 3 seconds with varying intensity NOMEX® IIIA - 6 oz/yd2 NOMEX® IIIA - 6 oz/yd2 3 seconds @ 2.02 cal/cm2s 3 seconds @ 2.36 cal/cm2s Total Exposure: 6.06 cal/cm2 Total Exposure: 7.08 cal/cm2 16.4% Predicted Body Burn Injury 43.4% Predicted Body

  44. Slide 44: Intensity and Predicted Body Burn Injury %

    INTENSITY AND PREDICTED BODY BURN INJURY % NOMEX® IIIA at 3 seconds with varying intensity 44 Copyright© 2013 E.I. du Pont de Nemours and Company. “ This material is only intended for this (webinar) and may not be used for any other purpose without the expressed written consent of DuPont”

  45. Slide 45: Intensity and Predicted Body Burn Injury %

    INTENSITY AND PREDICTED BODY BURN INJURY % You can generate total exposure by changing intensity NOMEX® IIIA - 6 oz/yd2 88/12 FR Treated Cotton / Nylon – 7 oz/yd2 3 seconds @ 2.36 cal/cm2s 3 seconds @ 2.36 cal/cm2s Total Exposure: 7.08 cal/cm2 Total Exposure: 7.08 cal/cm2 43.4% Predicted Body Burn I

  46. Slide 46: Intensity and Predicted Body Burn Injury %

    INTENSITY AND PREDICTED BODY BURN INJURY % You can generate total exposure by changing intensity 46 Copyright© 2013 E.I. du Pont de Nemours and Company. “ This material is only intended for this (webinar) and may not be used for any other purpose without the expressed written consent of DuPont”

  47. Slide 47: Predicted Body Burn Injury % at Increased Intensity

    PREDICTED BODY BURN INJURY % AT INCREASED INTENSITY NOMEX® IIIA, 6 oz/yd2  3 seconds @ 2.36 cal/cm2s  Total Exposure: 7.08 cal/cm2  Predicted Burn Injury: 43.4% 88/12 FR Treated Cotton / Nylon, 7 oz/yd2  3 seconds @ 2.36 cal/cm2s  Total Exposure: 7.08 cal/cm2  Predicted Burn Injury: 83.6% 47 C

  48. Slide 48: Impact of Hazard & Apparel Selection on Survivability

    IMPACT OF HAZARD & APPAREL SELECTION ON SURVIVABILITY Chances of surviving nearly triples with garments made of Nomex® EXAMPLE Total Exposure Energy: 7.08 88/12 88/12 FRTC FRTC (7 (7 oz) 31 oz) 84 cal/cm2 Testing conditions: 41% variance  Intensity: 2.36 cal/cm2sec  Duration: 3 seconds Nomex® (6 N

  49. Slide 49: Key Duration & Intensity Takeaways

    KEY DURATION & INTENSITY TAKEAWAYS Industrial fires do not have a consistent duration and intensity Using 3 seconds as a “general rule of thumb” is not an accurate way to establish the level of protection workers need The 3 seconds concept is rooted in a test method developed for the military; and t

  50. Slide 50: DuPont Thermo-Man: How You Know You Picked the Right FR Clothing

    DUPONT THERMO-MAN® How you know you picked the right FR clothing 50 Copyright© 2013 E.I. du Pont de Nemours and Company. “ This material is only intended for this (webinar) and may not be used for any other purpose without the expressed written consent of DuPont”

  51. Slide 51: Why Do We Use DuPont Thermo-Man?

    WHY DO WE USE DUPONTTM THERMO-MAN®? When it comes to fire protection, companies need to be prepared for the worst-case scenario, not the best A UL manikin testing facility certified to NFPA 2112 Used for NFPA 2113 clothing performance assessments Enables a direct comparison of materials under the sa

  52. Slide 52: How Thermo-Man Helps You With NFPA 2113?

    HOW THERMO-MAN® HELPS YOU WITH NFPA 2113? Clothing systems designed to address your hazards Visit our Thermo-Man® facility in Richmond, VA Attend or host a Thermo-Man® event at your facility or conference with DuPont’s one of a kind traveling unit You can use the video and data from the testing to e

  53. Slide 53: Conclusions

    CONCLUSIONS NFPA 2112 compliance may not mean adequate protection Fires are unpredictable – duration and intensity matter Thinking all fires last 3 seconds is a misconception Thinking all fire intensities are equal (2 cal/cm2s) is a misconception NFPA 2112 garment compliance/certification does not m

  54. Slide 54: Thank You for Attending!

    Thank You for Attending! For additional questions, please visit www.nomex.com 54 Copyright© 2013 E.I. du Pont de Nemours and Company. “ This material is only intended for this (webinar) and may not be used for any other purpose without the expressed written consent of DuPont”

  55. Slide 55: Substantiation

    SUBSTANTIATION  “This information corresponds to our current knowledge on the subject and may be subject to revision as new knowledge becomes available. It is your responsibility to investigate other sources of information on this issue that more appropriately addresses your product and its intende

DuPont — Technical Presentation (2013) on 6ix