Slide 1: TB-LAMP: New validation study and its importance to find the missing millions
“TB -LAMP: New validation study and its importance to find the “missing millions” Dr. Sunil Sethi Professor, Department of Medical Microbiology Post Graduate Institute of Medical Education & Research, Chandigarh

Slide 2: Introduction
Introduction • Tuberculosis- very high morbidity and mortality among infectious disease • 10 million cases globally in 2018. • India has the highest burden of TB with ~25% of global TB (~2.8 million new cases/year). WHO TB Report 2017 • In India, problem is more complex due to - Higher incidence - I

Slide 3: The Problem of Missing the Millions
The Problem of “Missing the Millions” Total Suspects: 40-45 Mn • Though, patients enrolled under DOTS program increased, yet it is not reaching to 100% target SSM ~20 million • Many people are escaping diagnosis due to insufficient capacity even after instituting ACF campaign Xpert TruNat (3-5 (2-3

Slide 4: India's End TB 2025
India’s End TB 2025 Which test is actually required for TB diagnosis ? 1. Can be performed at peripheral settings 2. Minimal requirement of training 3. Better or equal sensitivity and specificity than the existing tests at peripheral health settings 4. Rapid and cost effective , simple - help in tre

Slide 5: Current TB diagnostics tests
Current TB diagnostics tests • Smear Microscopy - 50-60% sensitive and misses almost every alternate case • Culture - 2 to 4 weeks to become positive • The NAAT’s(PCR based ) like Xpert MTB/RIF/ True Nat(Mol bio)- - Needs a costly infrastructure - Trained staff - Limited to tertiary and secondary ca

Slide 6: Current available tests
Test Sensitivity Essential Requirements Penetration Limitations Cost / Cost of Current available tests instrument Diagnosis Smear 50-60% (LED Sputum Processing, Staining, Until the CHC •Subjective , Rs 1-1.5 Rs 75-100/test Microscopy Microscopy is Manual intervention, (approx. 20000 • tedious sample

Slide 7: The Proposed Solution: TB-LAMP Assay
The Proposed Solution: TB-LAMP Assay • Isothermal amplification Method • High sensitivity and specificity • Visible detection of positive samples (through fluorescence) • No cold chain requirement and can be performed in room temperature conditions

Slide 8: Our Experience
Our Experience Evaluation of In-House Loop-Mediated Isothermal Amplification (LAMP) Assay for Rapid Diagnosis of M. tuberculosis in Pulmonary Specimens Sethi S et al. JCLA, 2013 First Indian Study on in-house TB-LAMP assay

Slide 9: Combination of adenosine-deaminase and nucleic acid amplification assays for tuberculous pleural effusion
Combination of adenosine-deaminase and nucleic acid amplification assays for diagnosing tuberculous pleural effusion Sethi S et. al. J Infect. 2014

Slide 10: LAMP assay for Mycobacterium tuberculosis in infertile women
Loop-mediated isothermal amplification assay for detection of Mycobacterium tuberculosis complex in infertile women Sethi S et al. Indian J Med Microbiol. 2016 • Sensitivities of ZN smear, culture, HPE, PCR and LAMP were 2.94%, 10.29%,8.82%, 95.59% and 66.18%, respectively. • Concordance between PCR

Slide 11: The WHO Endorsed TB-LAMP Assay (Eiken, Japan)
The WHO Endorsed TB-LAMP Assay (Eiken, Japan) • TB-LAMP (Eiken, Japan) – WHO endorsed in 2016 • Based on isothermal amplification and strand displacement principle, no requirement of costly PCR based instrument • High sensitivity (>95%) and specificity (~98%)- (LOD of 100 CFU/ml) • 15% more patients

Slide 12: TB-LAMP Workflow – Quick and Reliable!
TB-LAMP Workflow – Quick and Reliable! 1 2 3 4 Sample Pure DNA Reaction mix Result transfer LAMP reaction extraction preparation reading & lysis Time to result approx.1-1,5h 16 tests/run

Slide 13: How TB-LAMP will help in diagnosis of Missing millions
How TB-LAMP will help in diagnosis of Missing millions • Can reach up to CHC level, making it the only option which gives fast and accurate diagnosis • Through battery/solar power, can reach to even remote areas (thus making access/sample collection easy) • Increase of scale will reduce the cost/tes

Slide 14: TB-LAMP Test Performance - WHO Policy Guideline 2016
TB-LAMP Test Performance -WHO Policy Guideline 2016 Gray et al. study featured 2 Indian sites – PGIMER, Chandigarh and MGIMS, Wardha

Slide 15: TB-LAMP Test Performance - WHO Policy Guideline 2016
TB-LAMP Test Performance -WHO Policy Guideline 2016 Pooled sensitivity-77-80% Specificity-97-98%

Slide 16: Evaluation of the TB-LAMP assay in Northern India
INT J TUBERC LUNG DIS 21(10):1150-1153 © 2017 The Union http://dx.doi.org/10.5588/ijtld.17.0035 Evaluation of the TB-LAMP assay for the rapid diagnosis of pulmonary tuberculosis in Northern India R. Yadav,* N. Sharma,* R. Khaneja,* P. Agarwal,** A. Kanga,’ D. Behera,” S. Sethi* *Department of Medica

Slide 17: Diagnostic accuracy of TB-LAMP assay in pulmonary TB patients from North India
Determination of diagnostic accuracy of TB - LAMP assay in pulmonary tuberculosis patients from North India • Total samples(n)= 234 • 120 TB suspects+ 117 pulmonary disease(other than TB) Group Name of the Test Sensitivity Specificity Positive Negative predictive value Predicative Value Overall Xper

Slide 18: TB-LAMP assay for diagnosis of pediatric tuberculosis
TB-LAMP assay for diagnosis of pediatric tuberculosis: A prospective cohort study • Respiratory samples(n)= 187 • (GA/GL/BAL/Sputum) Sensitivity Specificity PPV NPV TB-LAMP 80% (95% CI, 96.1% (95% CI, 76.9%(95% CI, 96.7%(95% CI, 93- 59.3-93.2%) 91.6-98.5%) 59.8-88.2%) 98.5%) Xpert MTB/RIF 84%(95% CI

Slide 19: TB-LAMP is part of WHO EDL
TB-LAMP is part of WHO EDL Still need high quality studies under programmatic conditions in India at peripheral level

Slide 20: Multi-centric validation of WHO approved TB-LAMP assay
“Multi-centric validation of WHO approved TB-LAMP assay for detection of Mycobacterium tuberculosis in suspects of Pulmonary tuberculosis in peripheral settings” Objectives of the study- 1. To elucidate the diagnostic accuracy of TB-LAMP assay in sputum samples of suspected tuberculosis patients at

Slide 21: Methodology
Methodology • A total of 2400 TB suspects will be enrolled at 5 peripheral sites in different states. ( The sample size was calculated taking the sensitivity of 78% and specificity of 98% with a desired precision of 7% at 95% confidence interval. Using these parameters, the sample size is 2251. If w

Slide 22: Participating Sites
Participating Sites • PGIMER, Chandigarh (Parent Institute) • MGIMS, Wardha • Lucknow • Guwahati, Assam • Kochi, Kerala • Punjab

Slide 23: Level of Training required
Level of Training required • TB-LAMP can be operated by a minimally trained technician – could be paramedic, lab technician or a physician. • Such people need to be trained on sputum sample collection and handling in a bio- safety environment • 3-day hands-on training which will be imparted by the P

Slide 24: Thanks
Thanks
Source: Internet Archive copy of eiken.co.jp
More decks from Eiken Chemical Co., Ltd.
Q2 FY2027 Earnings Presentation19 slides · Oct 29, 2026
Q1 FY2027/3 Earnings Presentation11 slides · Jul 30, 2026
Q1 FY2025 Earnings Presentation19 slides · Jul 31, 2024
Technical Presentation (October 2023)17 slides · October 2023
Technical Presentation (March 2020)12 slides · March 2020
The 50th Union World Conference on Lung Health 201915 slides · Nov 2, 2019