Holley Inc. · NYSE:HLLY
Holley — Technical Presentation
35 slides from Holley's technical presentation

Slide 1: The Pinnacle of Programmable Power
Home e Shop by Product e ‘Shop by Vehicle e Apparel THE PINNACLE OF PROGRAMMABLE POWER! —— ‘© New modules coming throughout the year © Ultimate ignition control =—S ¢ USB Connection to your PC for programming * MSD View offers easy-to-run software Se © Micro-SD for unparalleled data acquistion —_ Ex

Slide 2: Power Grid
Power Grid • USB connection for ease of programming • Timing based on engine rpm, gear and time • Individual cylinder timing based on gear and time • Five retard stages for nitrous • Four rpm limits for Max Rev, Launch, burnout and spool • Output switch configured by rpm, time or both • Shift light

Slide 3: MSD Power Grid CAN Bus System
MSD Power Grid CAN Bus System FED 12V SW OUT BLACK - BATTERY (-) YELLOW. SHIFT UGHT ORANGE - BATTERY 12V GRAY -TACH WHITE - POINTS OUT — BRN/WHITE - RPM/TIME SWITCH LUT, BLUE - BURN OUT BLUE- LAUNCH. WHITE - POINTS IN BIN: STEP? VIOLET- STEP 2 TAN. STEP 3 LT, GREEN - STEP 4 GREEN. STEP 5 SWITCHED IG

Slide 4: Setting Timing
Setting Timing Set Maximum Timing normally same as crank trigger pickup setting Set Start Retard Set Individual Cylinder Timing Set Gear Retards Set Launch Retard (Timing By Time) Set Step Retards for NOS, (make sure to add Off Delay) Set Shift Retard

Slide 5: Setting Maximum Timing
Setting Maximum Timing ‘a MsdView 7730 Power Grid Controller File Edit Connect View Data Acquisition Window Help aaa oo a / SETTINGS \ IGNITION TIMING | REVLIMITER , DATAACQUISITION | NOTES / GENERAL | GEAR SHIFT | SHIFTLIGHT | OUTPUT SWITCH SETTINGS GENERAL Function Value Units Number of Cylinders

Slide 6: Setting a Start Retard
Setting a Start Retard Main Timing Right Click to Add a Dot then drag down Start Retard

Slide 7: Setting Gear Retards
Setting Gear Retards To select and make changes to a Timing Curve, click “Sel” Gear 1 Gear 2 Gear 3

Slide 8: Setting Individual Cylinder Timing
Setting Individual Cylinder Timing Set Firing Order Set Cylinder # 3 to retard 1.5 Degrees starting in 2 gear at 0.3 seconds

Slide 9: Setting Individual Cylinder Timing
Setting Individual Cylinder Timing .5 Degrees advanced at 0.80 seconds, resulting in a 1 degree retard in 2 gear.

Slide 10: Setting Launch Retard Time
Setting Launch Retard Time The Timing Map can be set to 0 to10 Seconds or 0 to10 Minutes.

Slide 11: Setting Launch Retard
Setting Launch Retard This Timing profile will start when the Dark Blue wire is released. Timing will change by time from 0 to 10 seconds.

Slide 12: Launch Retard with Zoom
Setting Launch Retard with Zoom To Zoom in “Right Click” and Zoom In

Slide 13: Step Retards With an Off Delay
Setting Step Retards With an Off Delay Special Note for Step 5 There are five Step Retards The “Off Delay will act as a safety for WOT step off. This will allow the 11 degrees to remain “ON” during a peddle. The NOS will turn off just not the Timing.

Slide 14: Setting Shift Retards
Setting Shift Retards “Shift Retard” is determined by “RPM Drop” from the peak of the shift. As the RPM drops, at 400 it will Retard 2 degrees for The RPM Drop can 0.07 seconds. be adjusted on the pull down tab Caution: Setting the “RPM Drop” too tight can activate on a bump on the track

Slide 15: Setting Rev Limiters
Setting Rev Limiters Burn out Rev Limiter is controlled by the Light Blue wire. Launch Rev Limiter is controlled by the Dark Blue wire. Maximum Rev Limiter will also over ride all limiters. Spool / Step 5 Rev Limiter is controlled by both Light and Dark blue wires powered at the same time. Safety Re

Slide 16: Setting Rev Limiters
Gl MsdView 7730 Power Grid Controller Setting Rev Limiters File Edit Connect View DataAcquisition Window Help ie Been Be | | SETTINGS | IGNITIONTIMING ) REVLIMITER \ DATAACQUISITION \ NOTES \ / SETTINGS \ REV LIMITER SETTINGS Function Value Units Burn Out Rev Limiter 7000 RPM Latched Launch Rev Limi

Slide 17: Data Acquisition
Setting Data Acquisition These are the channels that the Power Grid will record, 19 Channels

Slide 18: Data Acquisition to Start and Stop Recording
Setting Data Acquisition to Start and Stop Recording The Stop Recording Settings are: These are the factory default settings

Slide 19: Data Acquisition to Trouble Shooting
Setting Data Acquisition to Trouble Shooting Set the Stop Recording to 800 RPM To use the data logger to help trouble shooting adjust to “None”. Now it will start recording once the engine RPM is above 1000 RPM.

Slide 20: RacePak Channels
Setting RacePak Channels Using a V-Net T cable connected to the Power Gird, these channels will be sent to the Racepak data logger. Each will count as a Channel to Racepak. Make sure they are available in the Racepak, if not Enable what’s important

Slide 21: Channels Read into Racepak Show Up with MSD
Once the Channels are Read into the Racpak they will show up with “MSD” in front of the Channel name.

Slide 22: Live Dashboard
Live Dashboard SETTINGS \ IGNITION TIMING \ REVLIMITER | ‘| * |p / Monitor ) Gauge 1 ( Gauge 2 \ GENERAL \ GEARSHIFT | SHIFTLIGHT | 0‘ |” SETTINGS GENERAL Impot Settings] | ¢ Function Value Units : ; Number of Cylinders 8|-] Cylinders 5.0 : + to Maximum Timing Reference 28.0 DEG : STN Maximum Total

Slide 23: Starting the Engine and Setting Timing
Starting the Engine and Setting Timing Set the dash with these gauges, Once the engine is running bump the transbreak or clutch and “Gear” should read 1, Timing Retard should also read 0. Check Timing with a timing light and adjust to desired timing. That number should be entered to Max and Main Tim

Slide 24: How To Download a Recording
How To Download a Recording To open a recording click on “Recordings” or “F7” on the keyboard

Slide 25: Programmable 3 Stage Timer PN 7760
Programmable 3 ARC Module Boost Retard Boost Controller Stage Timer PN 7761 Module Module PN 7760 PN 7762 PN 7763/ PN 77631* • 3 individual • 2 Timing Curves to • Retards Timing Curve • 2 Selectable Boost Curves channels control engine power based on Boost Pressure • Over boost shut down • Programme

Slide 26: 7761 ARC Module
7761 ARC Module Mopute [D) face FFI PM USER PN7761 CONTROL CONFIGURABLE INPUT (PULSES PER DRIVE SHAFT REV) : 0% USER CONFIGURABLE OUTPUT (PULSES PER DRIVE ‘SHAFT REV) CONNECTS TO RACEPAK 3-PIN g iT USED S- GROUND eyerere se ACTIVE &-PIN TERIMINATED OUTPUT {SHAFT SENSOR. of GrSISNAs, WIRES: The wire

Slide 27: Drive Shaft: Curves
Drive Shaft: Curves Trace Edit Rev Limit Curve fe) Retard Curve A (o) Retard Curve B o Driveshaft RPM-33 Load Driveshaft RPM-33 Load Load trace from file. Load Time Fiom Drive Shaft Launch RPM | oo 0.70 2041 1.30 2895 246 4770 372 6291 468 7041 momoee? Drive Shaft RPM Drive Shaft RPM vs Time From La

Slide 28: File View Help
File View Help. ecoing Tee Too lst pet pa 7730_131_0086sGuP-44 | Pace? [Page [Page | Paget | Page] @ Erane RM 7730_131.0086-scuP-f i 8 Egee Teng Curl 6156212 Launch ‘Cur2: 3248.939 @ bum ox BY: 2907.27 few ates Oc aaa 28S @ sot Lane 7730_131_0086-scMP- @ ower Suach Engine Timing Bioworn cures ; @ to

Slide 29: Manual Launch Control – Connector Hub
Manual Launch Control 4 –Connector Hub PN 7751 PN 7740 • Change Launch RPM without Laptop • Allows to plug in up to 3 additional Modules • Displays Engine RPM • Adjust Shift Light brightness • Allows last minute global timing changes

Slide 30: 7764 Programmable Power Module
7764 Programmable Power Module

Slide 31: Power Module Output Settings
Suse i a Nee ee ae eee ee Fie Edit Connect View Data Acquisition Help ZEGREB | GENERAL SETTING] OUTPUT SETTINGS |QUTPUT DUTY CYCLE | TIMING | DATA ACQUISITION] » Monitor GaugeT =| 1-RED |2-ORANGE |3-PINK] 4-YELLOW] h OUTPUT SETTINGS: 1-RED \ et gn0l antes Function Value Units 06: Active State ON Sel

Slide 32: 7760 Programmable 3-Stage Delay Timer
7760 Programmable 3-Stage Delay Timer

Slide 33: Output Switch
OUTPUT SWITCH Edit Connect View Data Acquisition Data Acquisition Enable Select a 2 " OUTPUT SWITCH: Function Value Units RPM Switch Enabled Select RPM ON 0 RPM OFF Time Switch DEED Select Activation Point 0.00 SEC Duration 0.00 SEC LAUNCH INPUT OFF All Name. SWITCH_1 SWITCH_2 ‘SWITCH_3 LAUNCH INPUT

Slide 34: Multi Accessory CAN-Bus Connection
Multi Accessory CAN-Bus Connection

Slide 35: Wiring Connections
1- GREEN - STEP 5 2-LT GREEN - STEP 4 3 - BRNWHT - RPM/TIME SW 4 - YELLOW - SHIFT LIGHT 5 - BLUE - LAUNCH 6 - LT BLUE - BURN OUT 7 - PINK - STEP 4 8 - VIOLET - STEP 2 9 -TAN - STEP 3 LEGACY IGNITION/ 10 -WHITE - POINTS IN CAM SYNC 11 - RED - SWITCHED 12V 12 - GRAY - TACH A. GRN MAG(-), B. VIO MAG (+
Source: company website
More decks from Holley Inc.
Q2 2026 Earnings Presentation28 slides · Aug 5, 2026
Q1 2026 Earnings Presentation28 slides · May 6, 2026
Q4 2025 Earnings Presentation27 slides · Mar 4, 2026
Investor Presentation (2026)8 slides · 2026
Q3 2025 Earnings Presentation24 slides · Nov 7, 2025
Q2 2025 Earnings Presentation27 slides · Aug 6, 2025