Slide 1: Rotary preparation
ZVDW Rotary preparation
Slide 2: Requirements for shaping
Requirements for shaping ▪ Retention of the original path of the canal ▪ Consistently conical canal path from the coronal to the apical part ▪ Preservation of the apical constriction ▪ The identified working length and the preparation length must match. Avoid over- or under-instrumentation 2
Slide 3: Preparation errors
Preparation errors Zip Isthmus Apical Lateral Ledge (elbow) perforation perforation 3
Slide 4: The VDW Endo-System
The VDW Endo-System The remix taking rotary preparation to the next level 14.06.2021 VDW.ROTATE 4
Slide 5: VDW.ROTATE – Instruments
VDW.ROTATETM – Instruments Scouting C-Pilot #10 Basic sequence Glide Path15.04 for the majority 20.05 of the cases Option 1 Option 2 for the majority of cases for narrow / highly curved canals incl. apical curvature 25.06 25.04 30.06 30.04 Shaping of larger 35.06 35.04 canal anatomies Mix and match
Slide 6: VDW.ROTATE – Product Features
VDW.ROTATETM – Product Features Continuous Rotation 11 mm handle Shaft ISO color coding (Nickel plating) Blue silicone stop Rings for taper identification 14.06.2021 VDW.ROTATE 6
Slide 7: VDW.ROTATE – Product Features
VDW.ROTATETM – Product Features 3 instrument lengths: 21, 25, 31 mm Active length: 16 mm White Radiopaque Calibration Rings Instrument length Calibration rings at: 21 mm 18, 19, 20 mm 25 mm 18, 19, 20, 22 mm 31 mm 18, 19, 20, 22, 24 mm 14.06.2021 VDW.ROTATE 7
Slide 8: VDW.ROTATE – Sizes
VDW.ROTATETM – Sizes 1 ring 2 rings 3 rings 15.04 .04 .05 .06 20.05 25.04 25.06 30.04 30.06 35.04 35.06 40.04 40.06 50.04 60.04 14.06.2021 VDW.ROTATE 8
Slide 9: VDW.ROTATE – Dimensions Basic Sequence
VDW.ROTATETM – Dimensions Basic Sequence D13 D3 D0 0,67 0,27 0,15 15.04 0,85 0,35 0,20 20.05 1,03 0,43 0,25 25.06 0,77 0,37 0,25 25.04 14.06.2021 VDW.ROTATE 9
Slide 10: VDW.ROTATE – Retreatment File
VDW.ROTATETM – Retreatment File ISO 25.05 Same shaft, taper and ISO color coding SE NiTi wire Active tip Blue silicone stop 21 mm length only 14.06.2021 VDW.ROTATE 10
Slide 11: VDW.ROTATE - Heat Treatment
VDW.ROTATETM - Heat Treatment ▪ Blue and grey colors result from one unique heat treatment ▪ Oxide layer forms differently on flutes vs shaft 14.06.2021 VDW.ROTATE 11
Slide 12: VDW.ROTATE - Heat Treatment
VDW.ROTATETM - Heat Treatment Steel SE NiTi VDW.ROTATETM rigid flexible Schematic illustration 14.06.2021 VDW.ROTATE 12
Slide 13: VDW.ROTATE - Benefits
VDW.ROTATETM - Benefits VERSATILITY RESPECT OF THE NATURAL CANAL ANATOMY ▪ VDW.ROTATE™ includes an intuitive 3 file basic sequence ▪ by choosing between taper .04 or .06 according to the → great for GPs shape of the canals ▪ plus a wide range of larger files (ISO 15-60) → highly ▪ The instruments wi
Slide 14: Summary of internal lab tests
Summary of internal lab tests VDW.ROTATE… ▪ Is up to 30% faster* ▪ Is up to 30% more flexible* ▪ Has 2.5x less canal transportation* ▪ Has increased space for debris removal** ▪ Is up to 12x more resistant to cyclic fatigue* ▪ Is up to 4x more resistant to cyclic fatigue*** *compared to other VDW co
Slide 15: VDW.ROTATE – System
VDW.ROTATETM – System Matching paper points, gutta-percha cones and Guttafusion obturators with size verifiers 14.06.2021 VDW.ROTATE 15
Slide 16: VDW.ROTATE - Paper Points
VDW.ROTATETM - Paper Points ▪ Content: 180 pieces ▪ Assortment 60 × 25.06 60 × 30.04 30 × 35.04 30 × 25.04 ▪ Calibration Rings 3 markings = 6% Taper 2 markings = 4% Taper 14.06.2021 VDW.ROTATE 16
Slide 17: VDW.ROTATE – Gutta-Percha
VDW.ROTATETM – Gutta-Percha Injection Molded ✓ Superior apical fit ✓ Improved melting and flow characteristics, better heat conductivity ✓ Manufacturing tolerances +/- 0.03 mm ▪ Shape matching the instrument outline ▪ ISO color code identification ▪ Same radiopacity as other VDW gutta-percha 14.06.2
Slide 18: VDW Guttafusion & Size Verifiers
VDW Guttafusion & Size Verifiers The existing products also match VDW.ROTATETM ▪ Clinical benefits: ✓ The crosslinked gutta-percha core compacts the gutta-percha with a hydraulic force that sends it flowing equally in three dimensions – throughout the entire canal system. ✓ Easy to remove ✓ Easy hol
Slide 19: How to use VDW.ROTATE
How to use VDW.ROTATETM ▪ Pecking or Brushing motion is possible ▪ After the 15.04 and 20.05 choose between the 25.06 (majority of the canals) or 25.04 (narrow and highly curved canals) ▪ If further apical enlargement is needed, use ISO 30 and/or larger 14.06.2021 VDW.ROTATE 19
Slide 20: VDW.ROTATE – Motor Settings
VDW.ROTATETM – Motor Settings If not preset, use “Dr’s Choice” to enter the settings into your existing VDW motors and use 350 rpm. 14.06.2021 VDW.ROTATE 20
Slide 21: How to use VDW.ROTATE – Step by Step
How to use VDW.ROTATETM – Step by Step ▪ Scout and estimate working length ▪ Irrigate the canal 14.06.2021 VDW.ROTATE 21
Slide 22: How to use VDW.ROTATE – Step by Step
How to use VDW.ROTATETM – Step by Step ▪ You can use the instrument in either a pecking or brushing (on the outstroke) motion 14.06.2021 VDW.ROTATE 22
Slide 23: How to use VDW.ROTATE – Step by Step
How to use VDW.ROTATETM – Step by Step ▪ Create a glide path with 15.04 and prepare to working length with 20.05 ▪ Irrigate at every step and check patency 14.06.2021 VDW.ROTATE 23
Slide 24: How to use VDW.ROTATE – Step by Step
How to use VDW.ROTATETM – Step by Step ▪ Depending on canal size and curvature, use 25.06 or 25.04 for final step of basic preparation .06 OPTION .04 OPTION 14.06.2021 VDW.ROTATE 24
Slide 25: How to use VDW.ROTATE – Step by Step
How to use VDW.ROTATETM – Step by Step ▪ Dry and fill the canal OR 14.06.2021 VDW.ROTATE 25
Slide 26: Preparation with VDW.ROTATE: Basic sequence
Preparation with VDW.ROTATE™ Basic sequence
Slide 27: The VDW solution: The efficient NiTi System
The VDW solution The efficient NiTi System 27
Slide 28: Design
Design S-shaped cross-section Minimal ▪ Small instrument core giving high flexibility radial contact ▪ Two efficient cutting edges ▪ Deep and large chip space for dentine removal Maximum chip space for ▪ Low radial wall contact dentine removal 28
Slide 29: Design
Design Leaner cross-section of instruments with higher ISO sizes and tapers Minimal radial contact Benefits ▪ Maintains the flexibility of the instruments ▪ Ensures safe shaping with larger apical preparations (e.g. Mtwo® 35/.06) Maximum chip space for dentine removal 29
Slide 30: Design
Design Progressive pitch 25/.06 ▪ Good collection and uniform automatic removal of the dentine chips in the coronal direction ▪ Less resistance – breakage resistance ▪ Instrument can be easily advanced in the apical direction Progressive pitch ▪ No screw-in effect 30
Slide 31: Design
Design Short shaft Non-cutting instrument tip ▪ 11 mm long shaft, 5 mm ▪ Rounded instrument tip shorter than standard instruments prevents via falsa ▪ Considerably easier access to molars 31
Slide 32: Design
Design Instrument marking 10/.04 Taper identification using rings on the shaft Mtwo® Taper .04 1 ring Mtwo® Taper .05 2 rings Mtwo® Taper .06 3 rings Mtwo® Taper .07 4 rings ISO colour-coded markings 16 mm Depth markings Working length Depth marking at 21 mm 18, 19 and 20 mm 22 mm 18, 19, 20 and 22
Slide 33: Design
Design Working part in 16 mm and 21 mm for the instruments in the basic sequence 21 mm 16 mm working working part part The advantage of 21 mm: at the same time as preparation of the root canal, blockages in the pulp chamber are removed while protecting substance 33
Slide 34: Design
Design 10/.04 and 15/.05 for the preparation of an mechanical glide path ▪ Enlargement of the manual glide path ▪ Initial conical shaping to the full length of the root canal ISO 10 ISO 15 Taper .04 Taper .05 34
Slide 35: Design
Design Specific design for every instrument ▪ The large constant pitch angle of the 10/.04 allows a progressive movement in the apical direction (automatic penetration) ▪ The pitch angle changes for the larger instruments from small to large and ensures efficient dentine removal and high lateral cut
Slide 36: Design
Design Specific design for every instrument ▪ The small sizes have more thread turns and recessions which increases the stability ▪ The larger files have a progressive pitch, fewer turns and enable very good removal of dentine in the coronal direction (no blockages) 36
Slide 37: Paths to success = simultaneous shaping
Paths to success The right technology: ▪ Mtwo® cuts during the penetration and laterally ▪ The instrument advances automatically and successively from the coronal to the apical direction in brushing motion = simultaneous shaping 37
Slide 38: Paths to success: Single length technique - video
Paths to success Single length technique - video Brushing motion on the outstroke Source: Mtwo 4 Solo by Stefan Hilmer 38
Slide 39: Paths to success: Single length technique
Paths to success Single length technique Using Mtwo® instruments with the correct brushing movement is of the utmost importance, because this helps to reduce stress on the instruments and leads to optimum preparation results. 1 2 3 4 Insert the rotating instrument Exerting light pressure, Make small
Slide 40: The Mtwo basic sequence
The Mtwo® basic sequence 4 instruments for all canal anatomies 1. 2. 3. 4. 10/.04 15/.05 20/.06 25/.06 40
Slide 41: Clinical case study
Clinical case study Before treatment During treatment After treatment Tooth 4.6: Dr Nicola Grande, Rome 46
Slide 42: Summary of preparation
Summary of preparation Basic sequence Preparation of larger canal anatomies Obturation procedures 10/.04 Cold obturation 1 15/.05 30/.06 45/.04 2 5 8 20/.06 35/.06 50/.04 3 6 9 Warm obturation 25/.06 40/.06 60/.04 4 7 10 10/.04 30/.06 35/.06 40/.06 1 Warm obturation 5 6 7 15/.05 2 25/.07 20/.06 5 3
Slide 43: Obturation options
Obturation options Cold obturation Warm obturation (carrier based) Warm obturation (vertical compaction) Insert an Mtwo® gutta-percha point according Insert a GUTTAFUSION® according to the Insert an Mtwo® gutta-percha master point, to the size of the last instrument used and, as verified size of the
Slide 44: Recommendations
Recommendations Frequency of use of the instruments Interim cleaning of the instruments ▪ Single use is the safest option ▪ Remove debris from the flutes during ▪ The number of uses depends on the stress the preparation ▪ Documentation with the help of control stickers ▪ Using an Interim Stand with
Slide 45: Recommendations
Recommendations Use of LavEndo For cleaning instruments in the thermal disinfector 52
Slide 46: Retreatment with Mtwo
Retreatment with Mtwo® The right retreatment instruments in the sizes R15/.05 and R25/.05 with 16 mm working part ▪ Cutting tip for easy ▪ Efficient removal of root canal penetration into the gutta-percha fillings with only one instrument R15/.05 for narrow R25/.05 for wide and root canals moderate
Slide 47: Retreatment with Mtwo
Retreatment with Mtwo® Use ▪ Enlarge canal entrance with a Gates-Reamer ▪ Remove the gutta-percha in the coronal third ▪ Place the tip of the retreatment instrument on the gutta-percha filling and allow the instrument to rotate without applying pressure (280 rpm) ▪ Remove the gutta-percha with circu