Masimo Corporation · NASDAQ:MASI

Masimo — Investor Presentation (January 2011)

25 slides from Masimo's investor presentation, January 2011

  1. Slide 1: Rainbow Acoustic Monitoring

    Rainbow Acoustic Monitoring

  2. Slide 2: RAM Overview

    RAM Overview • Respiration Rate and Pulse Oximetry • Methods • Acoustic Respiration Rate (RRa) • RRa Accuracy • RRa Testimonials • Clinical Samples

  3. Slide 3: Respiration Rate (RR): A Complement to Pulse Oximetry

    Respiration Rate (RR): A Complement to Pulse Oximetry • Oxygen saturation is affected by • Breathing rate and depth • Lung function • Heart function • Relationship of RR to oxygen saturation • Very low respiration rate can lead to oxygen desaturation • Oxygen desaturation also caused by things other

  4. Slide 4: Respiration Rate

    Respiration Rate Respiration Depression Increased Respiration •Narcotic Induced Apnea •Tachypnea • PCA Pumps • 1st sign of metabolic • Epidural Narcotics decompensation • Oral Narcotics • Early indicator of physiologic •Obstructive Sleep Apnea (OSA) instability •Neurologic Disorders • Induce Central

  5. Slide 5: Current Respiration Rate Methods

    Current Respiration Rate Methods • Physical assessment (intermittent) • Transthoracic impedance (continuous) • Requires monitor and ECG electrodes • As chest expands impedance changes • Respiration rate measured from cyclical changes in impedance • No capital or increased sensor price (if already EC

  6. Slide 6: Recommendations: Post-Surgical Patient Monitoring

    Recommendations: Post-Surgical Patient Monitoring • The combination of patient-controlled analgesia and lower staff-to-patient ratios on the general floor make it less likely that a clinician will be there to observe an avoidable adverse event. • The Anesthesia Patient Safety Foundation Recommends:

  7. Slide 7: Respiration Rate Monitoring

    Respiration Rate Monitoring • Respiration rate is a critical vital sign that provides early detection of respiratory compromise and patient distress • Continuous monitoring of respiration rate is especially important for post-surgical patients receiving patient-controlled analgesia (PCA) for pain ma

  8. Slide 8: Acoustic Respiration Rate (RRa)

    Acoustic Respiration Rate (RRa) • When used with other clinical variables, first-ever continuous and noninvasive monitoring of acoustic respiration rate (RRa) may help clinicians assess respiratory status and help determine treatment options

  9. Slide 9: Acoustic Respiration Rate (RRa): How It Works

    Acoustic Respiration Rate (RRa): How It Works • Masimo Rainbow Acoustic Monitoring • Using patented acoustic signal noninvasively and continuously processing that leverages Masimo’s measures respiration rate using an revolutionary Signal Extraction innovative adhesive sensor with an Technology (SET)

  10. Slide 10: FDA Accuracy Study: Methods

    FDA Accuracy Study: Methods • Healthy adult subjects were instructed to breath at rates ranging from 4 to 30 breaths per minute (brpm) • Waveforms were collected from both capnography and Rainbow Acoustic devices • Control reference was created • First obtained by a trained observer marking each bre

  11. Slide 11: RRa FDA Accuracy Results: Similar to Capnography

    RRa FDA Accuracy Results: Similar to Capnography FDA Submitted Accuracy, N=26 healthy volunteers

  12. Slide 12: RRa Accuracy: Manual Method Comparison

    RRa Accuracy: Manual Method Comparison • Comparison of manual respiratory rate by stethoscope to Rainbow Acoustic Monitor RRa in 25 post surgical recovery patients

  13. Slide 13: RRa vs. EtCO2 for Respiratory Pause Detection

    RRa vs. EtCO2 for Respiratory Pause Detection • Data retrospectively analyzed from PACU and General Floor monitoring episodes • Reference respiration rate determined by expert observer throughout each monitoring episode • Respiratory pause defined as 30 seconds with no breathing activity • 86 monito

  14. Slide 14: Masimo Rainbow Pulse CO-Oximetry and Rainbow Acoustic Monitoring

    Masimo Rainbow Pulse CO-Oximetry and Rainbow Acoustic Monitoring Allow you to noninvasively and continuously monitor key indicators of: Oxygenation (SpO2) Ventilation (RRa™) Circulation (PR) Bleeding (SpHb™) • Helping you meet APSF guidelines for monitoring post-operative patients • Offering a break

  15. Slide 15: Rainbow Acoustic Monitoring Clinical Applications

    Rainbow Acoustic Monitoring Clinical Applications • General Care Floor with or without PSN • Any patient on Pain Management drugs (opioids) • All patients on PCA pumps • All OSA patients • All bariatric patients • Conscious Sedation Procedures (endoscopy, bronchoscopy) • PACU Patients • Patients cur

  16. Slide 16: Rainbow Acoustic Monitoring Devices

    Rainbow Acoustic Monitoring Devices

  17. Slide 17: Clinical Samples

    Clinical Samples

  18. Slide 18: RRa - RAM, RR - EtCO2, SpO2

    -- RRa - RAM -- RR - EtCo2-- SpO2

  19. Slide 19: RRa - RAM, RR - EtCO2, SpO2

    -- RRa - RAM -- RR - EtCo2-- SpO2

  20. Slide 20: RRa - RAM, RR - EtCO2, SpO2

    -- RRa - RAM -- RR - EtCo2-- SpO2

  21. Slide 21: RRa - RAM, RR - EtCO2, SpO2

    -- RRa - RAM -- RR - EtCo2-- SpO2

  22. Slide 22: RRa - RAM, RR - EtCO2, SpO2

    -- RRa - RAM -- RR - EtCo2-- SpO2

  23. Slide 23: RRa - RAM, RR - EtCO2, SpO2

    -- RRa - RAM -- RR - EtCo2-- SpO2

  24. Slide 24: RRa - RAM, RR - EtCO2, SpO2

    -- RRa - RAM -- RR - EtCo2-- SpO2

  25. Slide 25: Patient with desaturations and multiple respiratory pauses

    -- RRa - RAM -- RR - EtCo2-- SpO2 Patient with desaturations and multiple respiratory pauses