Study Design 1st head-to-head comparison of ACURATE neo2 & SAPIEN 3 Ul Objective: To compare VARC-3 device and technical success (Primary Endpoint) and 30-day VARC-3 clinical endpoints (Secondary Endpoint) of ACURATE neo2 to SAPIEN 3 Ultra Head-to-Head Transfemoral TAVR n = 1356 Patients | 4 German
Essential Outcomes ACURATE neo2 & SAPIEN 3 Ultra ACURATE neo2 SAPIEN 3 Ultra p-value n=472 n=472 Pre-dilatation, n (%) 434 (91.9) 148 (31.4) <0.001 Post-dilatation, n (%) 211 (44.7) 69 (14.6) <0.001 Procedural time, min 45.0 [36.0 – 59.0] 46.0 [35.0 – 57.0] 0.472 Fluoroscopy time, min 9.8 [7.3 - 13.
Slide 6: Essential Matched Cohort Outcomes
Essential Matched Cohort Outcomes ACURATE neo2 & SAPIEN 3 Ultra Similar and low Rates of Lower Mean Lower Severe PPVL = 0.686 Gradients Before TAVR After TAVR Prothesis-Patient 43+9 vs 43+8 mmHg 9+4 vs 13+4 mmHg Mismatch P < 0.001 0.6% 1.1% 20.0% P = 0.940 32.8% ACURATE neo2 2.9% 2.9% Severe PPM 78.
Slide 7: Conclusions
Conclusions ACURATE neo2 & SAPIEN 3 Ultra • First direct head-to-head propensity score matched comparison of the 2nd generation ACURATE neo2 and 4th generation SAPIEN 3 Ultra valves Data from this study demonstrated: – Low and similar rates of Moderate/Severe PVL (0.6% vs 1.1%; p=0.723)* and Permane
Slide 8: Study Limitations
Study Limitations ACURATE neo2 & SAPIEN 3 Ultra This is a non-randomized study, which incorporates 1:1 propensity matching (PSM), which does not fully exclude selection biases. Site-reported data are reported. No independent Core-Laboratory or Clinical Event Committee adjudication have been used
Slide 9: Backup: Entire Population Baseline Characteristics and Essential Outcomes