Honeywell International Inc. · NASDAQ:HON

Honeywell International — Investor Presentation (2017)

64 slides from Honeywell International's investor presentation, 2017

  1. Slide 1: Connected Campus. Customized Solutions.

    CONNECTED CAMPUS. CUSTOMIZED SOLUTIONS.

  2. Slide 2: NOTIFIER network solutions can be customized for complex requirements

    NOTIFIER’s network solutions for multi-building or large scale building applications can be customized to meet the most complex and challenging requirements  Central, single interface connecting separate, disparate systems giving you total control over your life safety system, increasing operationa

  3. Slide 3: Single Interface Solution

    (N)) NOTIFIER’ by Honeywell

  4. Slide 4: Networking is Key to a Single Interface Solution

    Product and Service Solutions Networking is Key to a Single Interface Solution 4

  5. Slide 5: What is Networking?

    What is Networking?  Allows multiple panels/products (referred to as “nodes”) be interconnected together, with the ability for inputs on one node to activate outputs on other nodes  UL requires there to be at least one network display node that can annunciate all nodes  NCA-2, ONYXWorks® Workstat

  6. Slide 6: NOTIFIER Networking

    NOTIFIER Networking Value Solution  Unified response - All  NOTI-FIRE-NET panels operate  LAN or WAN independently  Connect using wire, fiber or  Enhanced survivability IP (hybrid too!) – communications loss  Industry leading network will not compromise life node/panel capacity – up safety to

  7. Slide 7: ONYXWorks Single Interface Solution

    ONYXWorks® Single Interface Solution  ONYXWorks®  Monitoring fire and security  Custom floor plans pinpoint the exact location of events  Control of the system determined by user profiles  UL 864 (Fire) and 2572 (Mass Notification) listed  2572 listed Central Control Station Next generation in

  8. Slide 8: ONYXWorks

    ONYXWorks® Graphical User Interface (GUI) software that currently operates on Microsoft Windows 10 that supports the following clients:  Client Software  NOTIFY-IP  ONYX-Notify  NFN Gateway  Standard NFN and High Speed NFN  Receivers Gateway  Integrate any fire and security system via a DACT

  9. Slide 9: ONYXWorks Reduce Response Time with Fast Event Notification

    ONYXWorks® Reduce Response Time with Fast Event Notification  Centralized monitoring and control of multi-panel / multi-building fire alarm networks  Intuitive graphical display of emergency events overlaid on the building floor plan  Pinpoint the exact location of an emergency  Events are color

  10. Slide 10: ONYXWorks System Integration

    ONYXWorks® System Integration  Full control of fire only or integrated systems  NOTIFIER systems  Monitoring of third party fire  Monitoring of security systems  Interoperability of dissimilar systems and allows previously separate systems to be controlled as a single building system  Provide

  11. Slide 11: ONYXWorks Simple & Secure

    ONYXWorks® Simple & Secure Simple Maintenance Secure Access  Reports and flags trouble  Operator events on a real-time basis Login/Logout/Change  Valuable diagnostic tool so Password Function maintenance personnel monitoring the system are immediately alerted  Only authorized  History log allow

  12. Slide 12: ONYXWorks Home Screen

    ONYXWorks®— Home Screen FLOORPLAN 123\NO02\Screen 2 SUPERVISORY [i TROUBLE SECURITY DISABLED New Events (1) FREALARIA ADVISE Or RESTORE AMARA, Acknovledged Events (3) ACKED TROUBLE OTHER NOTIFIER by Honeywell

  13. Slide 13: ONYXWorks - Alarm

    ONYXWorks® - Alarm Automatic screen navigation based on event priority 13

  14. Slide 14: ONYXWorks - Trouble

    ONYXWorks® – Trouble Customizable colors represent each event type 14

  15. Slide 15: ONYXWorks - Disable

    ONYXWorks® - Disable Easy event identification 15

  16. Slide 16: ONYXWorks - History Manager

    ONYXWorks® - History Manager 16

  17. Slide 17: ONYXWorks Dual Monitors

    ONYXWorks® Dual Monitors Configurable Display for Dual Monitors 17

  18. Slide 18: ONYXWorks Embedded Gateway

    ONYXWorks® – Embedded Gateway  Can be connected via Ethernet IP using the NFN- GW-EM-3 to an entire NOTI-FIRE-NET network  Ethernet IP connection can be on shared IP or private network  Interfaces with NOTIFY-IP and DVCs Any Town, Anywhere Perfect solution for Wide Area Use 18

  19. Slide 19: ONYXWorks NOTIFY-IP

    ONYXWorks® – NOTIFY-IP  System of interconnected software and hardware that broadcasts live or prerecorded voice messages on DVCs  NOTIFY-IP gives you:  Wide Area Capability  Country to Country  State to State  City to City  Large Campuses 19

  20. Slide 20: ONYXWorks ECS and NOTIFY-IP

    ONYXWorks® – ECS and NOTIFY-IP ONYXWorks TM DVC w/NCA-2 Attention… with NOTIFY-IP Attention… DAL (Digital Audio Loop) NOTI-FIRE-NETTM TCPIP DAA-50 Series Amplifiers (up to 32) DAL (Digital Audio Loop) DVC (Digital Voice Command) with NFN Gateway 20

  21. Slide 21: Receivers Gateway

    Receivers Gateway  An intelligent gateway interface to digital alarm communicator receivers (DACR) for the ONYXWorks facilities monitoring workstation  Enables the ONYXWorks workstation to monitor remote fire and security panels equipped with Contact ID capable digital alarm communicator transmitt

  22. Slide 22: Digital Alarm Communications (DACT/DACR)

    Digital Alarm Communications (DACT/DACR) IPACT-2 UDACT COM PORT Ethernet FACPs ONYXWorks/ VisorAlarm Plus DACT IPACT-2 DACR-GW Integrate NON-NOTIFIER products into a common network for a Single Interface 22

  23. Slide 23: ONYX Series Integration Gateways

    ONYX Series Integration Gateways Product Application BACNET-GW-3 Integration with BACnet clients such as Building Management Systems MODBUS-GW Integration with Modbus clients such as DCS systems in industrial applications CAP-GW Integration with CAP compliant clients such as At-Hoc 23

  24. Slide 24: BACnet Gateway (BACNET-GW-3)

    BACnet Gateway (BACNET-GW-3)  Interface between an ONYX Series panel or NOTI•FIRE•NET and a network using the BACnet/IP communication protocol  Panel information available to BACnet /IP Client 24

  25. Slide 25: MODBUS Gateway (MODBUS-GW)

    MODBUS Gateway (MODBUS-GW)  Provides a communication link between networks that use the Modbus/TCP communication protocol and Fire Alarm Control Panels (FACPs) resident on an NFN network 25

  26. Slide 26: Common Alerting Protocol Gateway (CAP-GW)

    Common Alerting Protocol Gateway (CAP-GW)  Translates event information to industry standard CAP messages for use with CAP-compliant systems 26

  27. Slide 27: FirstVision

    FirstVision™ Revolutionary navigational tool for first responders Intuitive, interactive touch-screen displays critical information:  Source and spread of fire  Chemical or Physical Hazards in a building  Water Supplies  Evacuation Routes  Access Routes  Gas, Power & HVAC Shut-Offs  Common

  28. Slide 28: FirstVision

    FirstVision™  Campus view highlights areas of concern  Auto-navigation to event floor plan location  Time sequence display tracks progression of a fire Critical Information. Rapid Assessment. Effective, Strategic Response. 28

  29. Slide 29: FirstVision

    FirstVision™  Graphic and Text display of:  Fire  Supervisory  Security  Medical events  Interfaces with ONYX Series panels or NOTI-FIRE-NET over Ethernet  22” LCD Touch-screen 29

  30. Slide 30: Quickly Identify and Respond to Emergency Events

    QUICKLY IDENTIFY AND RESPOND TO EMERGENCY EVENTS

  31. Slide 31: NOTIFIER Emergency Communication Systems

    NOTIFIER Emergency Communication Systems Value Solution  Up-to-the minute  Digital Voice Command information  Broadcasting live  Inform everyone  Building  Reduce risk  Campus  Save lives  Multi-building spread across a city/state/global  Save property  Integrated, Expandable systems Prot

  32. Slide 32: Fire Alarm & Emergency Communication Systems

    Fire Alarm & Emergency Communication Systems ONYXWorks TM NOTIFIER 3030 with NOTIFY-IP with Digital Voice Notification Devices (Indoor Voice) LED Signage WAN w/Live Voice Outdoor Voice Email Text Messages 3rd Party Audio Integration Personal Notification Net-Centric Management Console Cisco IP Phone

  33. Slide 33: NOTIFIER ECS: Digital Voice Command (DVC)

    NOTIFIER ECS: Digital Voice Command (DVC)  Integrate with single FACP or part of Noti-Fire-Net  8 channel digital audio  Supports Firefighters Telephone  Local or Remote Paging  Analog Audio Option  Voice over IP Option  Integration with Third Party Systems: LED signage and Whelen “Giant Voic

  34. Slide 34: NOTIFIER ECS: DVC

    NOTIFIER ECS: DVC  Up to 32 Digital Audio Amplifiers can be connected to a DVC center  Each Digital Audio Amplifier is configurable as a primary or backup amplifier  Larger applications can be accommodated with additional DVC centers  Each networked DVC adds support for another 32 Digital Audio

  35. Slide 35: Third Party Integration

    Third Party Integration  DVC audio can be integrated into Third Party systems, such as Whelen Giant Voice  Ability to activate the Whelen system with high level audio from a speaker circuit  Proprietary NOTIFIER ~ Whelen interface  No control modules required! 35

  36. Slide 36: DVC Third Party Integration

    DVC Third Party Integration  Third Party Audio, such as Whelen Giant Voice, can be easily integrated into the DVC 36

  37. Slide 37: Digital Intelligent Signage

    Digital Intelligent Signage Value Solution  Pre-programmed or  Supplements emergency customizable emergency voice messaging with messages – examples: visual signage  Security Breach Reported  Fully integrated and  Lock Down supervised by ONYX  All Clear panels and ONYXWorks  Emergency message

  38. Slide 38: LEDSIGN-GW: ONYX integration gateway

    LEDSIGN-GW: ONYX integration gateway  Up to10 LED signs per gateway  Each sign can display a unique message based on programming  Encrypted communications to the sign  Bright LEDs with wide viewing angle 38

  39. Slide 39: NOTIFIER Web Server Gateway (NWS-3)

    NOTIFIER Web Server Gateway (NWS-3)  Access FACP status remotely over the internet or intranet  Send automatic emails or text messages (up to 50) View History Remotely Email Profile Configurations 39

  40. Slide 40: NOTIFIER ECS: Distributed Messaging

    NOTIFIER ECS: Distributed Messaging At-Hoc Integrates with NOTIFIER via the CAP-GW 40

  41. Slide 41: Progression of effectiveness in ECS technology

    Progression of effectiveness in ECS technology Ranging from indoor voice systems to full DRMNS functionality 41

  42. Slide 42: Solve Unique Detection Problems

    SOLVE UNIQUE DETECTION PROBLEMS Subtitle Here

  43. Slide 43: Advanced Intelligent Detection

    Advanced Intelligent Detection Value Solution  Separate pre-alarm from  Self-optimizing heat & smoke general evacuation alarm detectors combining thermal condition and photoelectrical  Prevent costly disruptions technologies  Reduced material and labor  Intelligent, multi-criteria costs detecto

  44. Slide 44: ONYX Intelligent Sensing Devices

    ONYX Intelligent Sensing Devices  Advanced Detectors – Widest range in the industry  ACCLIMATE™ Plus  IntelliQuad™  IntelliQuad PLUS™  VIEW™  Intelligent FAAST  SWIFT Wireless 44

  45. Slide 45: Advanced Aspiration Detection

    45 Advanced Aspiration Detection The broad and rapid development of safety solutions has allowed Advanced Detection ASD to expand from a few, targeted markets & applications to many… VESDA ECO VESDA VESDA Xenon VESDA Laser VESDA VLI OSID VLC-EX FAAST VESDA VEA 45

  46. Slide 46: Acclimate Plus – FAPT-851

    Acclimate Plus – FAPT-851 Over time, facilities are often used for many different purposes, forcing choices in fire detection that can mean reduced sensitivity or increased nuisance alarms  Acclimate Plus constantly monitors ambient conditions, adjusting detection parameters and alarm thresholds au

  47. Slide 47: IntelliQuad – FSC-851 (Multi-Criteria Detector)

    IntelliQuad – FSC-851 (Multi-Criteria Detector)  Using four sensing elements working together to address each element of a fire  Most accurate detection of the widest range of fires  Target building owners – especially those with a vested interest in maintaining operations or a progressive attitu

  48. Slide 48: IntelliQuad PLUS (FCO-851)

    IntelliQuad PLUS (FCO-851)  Maintains IntelliQuad advanced multi-criteria detection for smoke  Photoelectric  Thermal  Carbon Monoxide  Infrared  The carbon monoxide sensor provides a separate CO signal to the panel  Superior nuisance alarm rejection  Utilize B200S/B200S-LF* base for Temp- 4

  49. Slide 49: VIEW (Very Intelligent Early Warning) - FSL-751

    VIEW (Very Intelligent Early Warning) - FSL-751  VIEW laser system has an advanced laser light source and patented optical design  Addressable, spot detector. Alternative to aspirating systems in critical environments  Sensitivity that is 10 to 50 times higher than present photoelectric technolog

  50. Slide 50: Applications for ONYX Intelligent Sensing Devices

    Applications for ONYX Intelligent Sensing Devices 50

  51. Slide 51: SWIFT Wireless

    SWIFT Wireless  Smart Wireless Integrated Fire Technology  Patented proprietary wireless Mesh protocol For life safety and property protection in challenging environments 51

  52. Slide 52: NOTIFIER's SWIFT Wireless Overview

    NOTIFIER’s SWIFT Wireless Overview  SWIFT enables a Fire Alarm/Life Safety System to be hybrid configuration  Wired Intelligent Addressable Devices  Wireless Intelligent Addressable Devices  Consistent aesthetics as wired devices  Same addressing and programming parameters as wired devices 52

  53. Slide 53: SWIFT Components

    SWIFT Components FW-RM Relay Module 53

  54. Slide 54: Low Frequency

    LOW FREQUENCY Subtitle Here

  55. Slide 55: Solutions for Low Frequency

    Solutions for Low Frequency  Low Frequency Sounders  Low Frequency Sounder Base  Low Frequency Tones through Speakers 55

  56. Slide 56: Low Frequency Audible Solutions

    Low Frequency Audible Solutions Sounder Bases  B200S-LF (Intelligent, Addressable, Programmable)  Multiple Tones: Continuous, March Time, Temporal 3, and Temporal 4  Selectable volume: Low = 75 dB, High = 85 dB  Synchronization with System Sensor AV devices  B200SR-LF (Conventional)  Tones: Co

  57. Slide 57: Low Frequency Through Speakers

    Low Frequency Through Speakers DID YOU KNOW? All components involved in producing Low Frequency Tone must be tested to obtain UL listing Fire Alarm Control Panel Amplifier Speaker 520 Hz Tone 57

  58. Slide 58: DVC Low Frequency Documentation

    DVC Low Frequency Documentation  DVC and Digital Audio Amplifier Manuals address DVC and compatible amplifiers  Device Compatibility Document addresses compatible System Sensor Speakers and Speaker-Strobes 58

  59. Slide 59: NOTIFIER Differentiators

    NOTIFIER DIFFERENTIATORS Subtitle Here

  60. Slide 60: Global Presence, Local Knowledge

    Global Presence, Local Knowledge  Trusted Leader in Life Safety Technology  Delivering Innovative Life Safety Products for over 60 years  Over 400 independent global business partners (ESDs)  Trusted Provider of Life Safety Solutions  Fully backed by NOTIFIER  Design, Install, and Service tota

  61. Slide 61: Professional Services - FSG

    Professional Services - FSG  Factory support providing technical solutions, services, and support for your project.  Providing end-users one point of contact to assure superior service and support from Honeywell and Honeywell dealers.  Project services provided include:  Building Information Mod

  62. Slide 62: NOTIFIER – Fully Connected, Fully Protected.

    62 NOTIFIER – Fully Connected, Fully Protected. Feature Value NOTIFIER Offering  Central, single • Total control over your life • Network interface safety system Solutions/Applications  Customized and • Connected separate, integrated disparate systems • ONYXWorks/ solutions • Increased operational

  63. Slide 63: IMSA accreditation and contact information

    63 This program has been accredited by International Municipal Signal Association For more information please contact: Jeff Knight – IMSA International 800.723.IMSA IMSASafetey.org 63

  64. Slide 64: Questions?

    Questions? NOTIFIER by Honeywell

Honeywell International — Investor Presentation (2017) on 6ix