Cummins India Limited · NSE:CUMMINSIND
Cummins India — Investor Presentation (2012)
43 slides from Cummins India's investor presentation, Jan 8, 2012

Slide 1: Pulse Batteries – Sealed Maintenance Free (SMF)
Pulse Batteries Sealed Maintenance Free (SMF)

Slide 2: Overview of Lead-Acid Batteries
Overview of Lead-Acid Batteries

Slide 3: Battery technology classification
Battery technology classification Batteries Primary Secondary Cannot be charged Rechargeable Alkali Based Acid Based Eg. Nickel Cadmium Maintenance free Flooded Most (VRLA Batteries) Eg. Conventional Auto batteries advanced tech for Gel Electrolyte AGM Batteries engine starting Thick Plate Thin Plat

Slide 4: Maintenance free VRLA battery
Maintenance free VRLA battery Oxygen evolved at +ve plate is made to diffuse through the Separator electrolytre and recombine at –ve electrode Electrolyte is immobilized either as gel or in an AGM +Ve Plate In AGM, separator is not fully -Ve Plate saturated and voids allow passage of Oxygen VRLA bat

Slide 5: Components of Monobloc Lead acid battery
Components of Monobloc Lead acid battery Grid is the skeleton that hold active material & acts as electrical conductor Plate consists of Grid pasted with +ve(PbO2) or –ve (Pb) active material +ve & -ve plates are alternately leaved with AGM separator to form stack Lugs of plates of same polarity are

Slide 6: Mono bloc Lead-acid Battery – Cut Section
Mono bloc Lead-acid Battery – Cut Section

Slide 7: Lead Acid battery parameters
Lead Acid battery parameters Charge Charging is process of putting electrical energy into battery for storage in the form of electro-chemical energy. When charging is completed, battery is ready to release stored energy when subjected to discharge Discharge It is the process of conversion of electro

Slide 8: Lead Acid battery parameters
Lead Acid battery parameters Depth of discharge (DOD) – It is the capacity or charge removed from battery as percentage of its rated capacity Cycle life – It is the number of useful cycles that a battery is expected to perform at a given depth of discharge Float application – An application in which

Slide 9: Genset Battery
Part No: Genset Rating KVA: 160 to 500 nance Genset Battery, \ NL

Slide 10: Pulse lite
Pulse lite Sealed Maintenance Free GENSET Battery COMPACT – HIGH PERFORMANCE – RELIABLE – COST SAVER Delivering the future first. first.

Slide 11: Requirements of an Engine Starting battery
Requirements of an Engine Starting battery High cranking current capability Ability to crank cold engines or engines in idle condition for long time Good high & low temperature performance Compact & light weight Faster recharge capability No emission of corrosive fumes Long life, both in storage & w

Slide 12: Important Customer requirements
Important Customer requirements Customer Flooded Battery Cummins Pulse lite Requirement Battery Reliability of Starting Satisfactory Excellent No Electrolyte Adjustment required Maintenance-free adjustment frequently Readiness for use Needs electrolyte filling and Ready to use (filled & charging at

Slide 13: Pulse lite – SMF battery
Pulse lite – SMF battery Pure Lead-Tin thin plate Valve Self-resealing pressure Regulated Lead-acid (VRLA) regulating valve battery Rugged ABS lid Unmatched peak power performance. Copper alloy terminals with high electrical conductivity. Awesome starting capability Rugged ABS container Reliable sta

Slide 14: Pure Lead Tin Technology
PURE LEAD TIN TECHNOLOGY Unlike conventional Lead Acid Batteries, which use relatively thick plates (~3mm), Pure Lead- Tin batteries use thin electrodes (~1mm). Thin plate technology maximizes plate surface area within a smaller footprint to efficiently deliver high cranking currents for engine star

Slide 15: Conventional vs PLT thin plates
CONVENTIONAL PLT-THIN PLATE(~3mm) PLATES(~imm) SURFACE AREA DETERMINES CHEMICAL ACTIVITY

Slide 16: Product Technology
Product Technology Product design used in Pure Lead Tin Vs Other applications like Battle tank Lead Acid Batteries starting and aircraft starting Normally flooded type lead- Pure Lead-Tin calcium alloys with thicker grids Very high surface area. are used in battery. Very low corrosion in Battery use

Slide 17: Comparison of Lead-acid battery technologies
Comparison of Lead-acid battery technologies Parameter Conventional Thick Plate Pulse lite Remarks Flooded AGM Grid Alloy Typically Lead- Typically lead- Pure lead-Tin PLT has least corrosion rate & antimony or calcium (PLT) longer life lead-calcium Grid Thickness 4-5 mm approx 3-4 mm approx 0.6 to

Slide 18: Pulse lite – Features & benefits
Pulse lite – Features & benefits Maintenance free VRLA design – No battery topping up or specific gravity checks, No spillage of electrolyte, No corrosion or sulphation of battery terminals Ready to use – Compact & lightweight for easy handling, factory charged Reliable performance – High power capa

Slide 19: Pulse lite sizing
Pulse lite sizing Current required to start the genset engine depends on following – Starter motor rating – Efficiency of starter motor – Resistance offered by the engine as a result of viscosity of the engine oil depending on its temperature – Ambient temperature – No. of starts & each crank durati

Slide 20: General Selection guideline
General Selection guideline Replaces batteries of type No of Generator Kva Battery Batteries Battery Model rating rating required No of Rating per Genset batteries 15 to 25 PLT 65-12A 12V 65 Ah 1 12V 88 Ah 1 30 to 140 PLT 65-12A 12V 65 Ah 1 12V 150 Ah 1 160 to 380 PLT 65-12A 12V 65 Ah 2 12V 180 Ah 2

Slide 21: Comparison with Conventional battery
Comparison with Conventional battery Capacity Ah Dimensions (mm) Approx. Pulse lite Model CCA Wt.(Kgs) L W H PLT 65 – 12A 65 330 168 200 720 25.0 Typical 130 505 223 238 700 41.9 Equivalent 135 508 222 257 750 44.4 Flooded Battery Delivering the future first. first. COMPACT – HIGH PERFORMANCE – RELI

Slide 22: Comparison with Conventional battery
Comparison with Conventional battery Capacity Dimensions (mm) Approx. Pulse lite Model Ah CCA Wt.(Kgs) L W H PLT 100 – 12A 100 410 175 240 1100 36.0 Typical 200 521 292 250 850 62.0 Equivalent Flooded Battery Capacity Dimensions (mm) Approx. Pulse lite Model Ah CCA Wt. L W H (Kgs) PLT 160 – 12A 160

Slide 23: Shakti 'Zero Maintenance' Truck Battery
Bi SHAKT ‘Zero Maintenance’ Truck Battery

Slide 24: LCV & HCV Pure Lead Tin SMF Batteries
COMPACT – HIGH PERFORMANCE – RELIABLE – COST SAVER LCV & HCV Pure Lead Tin Sealed Maintenance Free Batteries for Automotive Applications Delivering the future first. first.

Slide 25: Comparison with Conventional battery
Comparison with Conventional battery Dimensions (mm) Approx. Cummins Shakti Model Capacity CCA Wt.(Kgs) L W H Ah AX1006968 32 163 142 225 500 12.5 Typical Equivalent 70 260 173 220 430 17.5 Flooded Battery Delivering the future first. first. COMPACT – HIGH PERFORMANCE – RELIABLE – COST SAVER

Slide 26: Comparison with Conventional battery
Comparison with Conventional battery Capacity Ah Dimensions (mm) Approx. Cummins Shakti CCA Wt.(Kgs) L W H Model AX1006970 65 330 168 200 720 25.0 Typical 130 505 223 238 700 41.9 Equivalent 135 508 222 257 750 44.4 Flooded Battery Dimensions (mm) Cummins Shakti Capacity Ah CCA Approx. Model L W H W

Slide 27: Shakti – Selection Guidelines
Shakti – Selection Guidelines APPLICATIONS – 32Ah – AX1006868 Vehicle Type OEM Model Jeep / SUV Bajaj Matador-F305 & 307 /Traveler / TRAX /Gama/Town /Judo HM Trekker/Oka M&M Armada/Commander/ Bolero /Voyager/Commander,/Maxx,/Saveri, TELCO Safari/Sumo/TataMobile/ Sierra/Estate APPLICATIONS- 65Ah - AX

Slide 28: Shakti – Selection Guidelines
Shakti – Selection Guidelines APPLICATIONS – 65Ah – AX1006970 Vehicle Type OEM Model HCV Leyland Comet/Tusker/Taurus/Viking/Che etah APPLICATIONS – 80Ah – AX1006971 Vehicle Type OEM Model HCV: Tata Motors SD400/SA/SAK/1613TC/2516/151 2TC/3516/2213/SE1613/SK/LP/LP T/LPO Delivering the future first. f

Slide 29: Pulse hd+ Heavy Duty Zero Maintenance

Slide 30: Pulse hd+ battery

Slide 31: Heavy Earth Moving Machinery
COMPACT – HIGH PERFORMANCE – RELIABLE – COST SAVER Heavy Earth Moving Machinery Delivering the future first. first.

Slide 32: Comparison of Pulse hd+ Battery with typical conventional battery
Comparison of Pulse hd+ Battery with typical conventional battery Capacity Dimensions (mm) Approx. Pulse hd+ Model Ah CCA Wt.(Kgs) L W H AX1006972 100 410 175 240 1100 36.0 Typical 180/200 521 292 250 850 62.0 Equivalent Flooded Battery Capacity Dimensions (mm) Approx. Pulse hd+ Model Ah CCA Wt. L W

Slide 33: Applications – 100Ah – AX1006972
COMPACT – HIGH PERFORMANCE – RELIABLE – COST SAVER APPLICATIONS – 100Ah – AX1006972 Vehicle Type OEM Model Dumpers BEML 35-T BH-35 HM 35-T 1035 Dozer BEML 300HP- BD30W / D80 / D50 Excavator L&T 3.9 cu.m 300CK Telcon 2.3 cu.m EX400 / EX300/ 600/ KH500// BEML TFC280/EX200LC-1/EX210/LCH- V/EX100 2.2 cu

Slide 34: Applications – 160Ah – AX1006973
COMPACT – HIGH PERFORMANCE – RELIABLE – COST SAVER APPLICATIONS – 160Ah – AX1006973 Vehicle Type OEM Model Dumper BEML 85-T BH-85

Slide 35: Giant 85-T BEML Dumper BH-85
GIANT 85-T BEML DUMPER BH-85 Delivering the future first. first.

Slide 36: The Battery: 2 x Pulse hd+ 160-12A
COMPACT – HIGH PERFORMANCE – RELIABLE – COST SAVER THE BATTERY 2 X Pulse hd+ 160-12A REPLACES FLOODED 4 X 12V 180/200Ah Delivering the future first. first.

Slide 37

Slide 38: Quality Assured
COMPACT – HIGH PERFORMANCE – RELIABLE – COST SAVER Quality Assured Battery conforms to IEC 60095 Rugged ABS plastic lid and container Best available high purity raw materials Automated production facility Comprehensive testing prior to despatch

Slide 39: Pollution Prevention
Pollution Prevention Battery handling, disposition and disposal fall under the hazardous waste materials and are regulated by laws Batteries (Management & Handling) Rules, 2001 have been notified which regulates collection, transportation, scrap & recycling of used batteries These rules apply to eve

Slide 40: Safety Precautions
Safety Precautions EXPLOSIVE GASES: Batteries when excessively overcharged can generate explosive gases, which in the presence of spark can explode and may cause blindness and other serious injury. The safety vent opens releasing the explosive gases which are being generated (i.e., in the event of o

Slide 41: Safety Precautions
Safety Precautions ELECTRICAL SHOCK AND BURNS: All installation tools should be adequately covered with vinyl electrical tape, or suitable non- conducting material to minimize possibility of shorting across connections. Never lay tools or other metallic objects on modules as shorting, explosions and

Slide 42: Safety Precautions
Safety Precautions SULFURIC ACID BURNS: Batteries contain sulfuric acid, which can cause burns and other serious injury. In the event of contact with sulfuric acid, flush immediately and thoroughly with water. Secure medical attention immediately.

Slide 43: Thank you
Thank you em
Source: Internet Archive copy of cumminsindia.com
More decks from Cummins India Limited
Shareholder Meeting (August 2026)15 slides · Aug 6, 2026
Shareholder Meeting (August 2025)16 slides · Aug 8, 2025
Investor Presentation (February 2025)20 slides · Feb 17, 2025
Shareholder Meeting (August 2024)17 slides · Aug 7, 2024
Shareholder Meeting (August 2023)20 slides · Aug 3, 2023
Shareholder Meeting (August 2022)18 slides · Aug 10, 2022