Perceptive Capital Solutions Corp · NASDAQ:PCSC

Perceptive Capital Solutions — SPAC Merger (July 2026)

17 slides from Perceptive Capital Solutions's SPAC merger presentation, Jul 9, 2026

  1. Slide 1: SimpleScreen v2 sPMA Top-Line Readout

    July 9th, 2026 SimpleScreen v2 sPMA Top-Line Readout

  2. Slide 2: Disclaimer: Forward Looking Statements

    Disclaimer Forward Looking Statements Certain statements included in this Presentation that are not historical facts are forward-looking statements. Forward-looking statements generally are accompanied by words such as “believe,” “may,” “will,” “estimate,” “continue,” “anticipate,” “intend,” “expect

  3. Slide 3: Disclaimer (Cont'd)

    Disclaimer (Cont’d) If any of these risks materialize or PCSC’s or Freenome’s assumptions prove incorrect, actual results could differ materially from the results implied by these forward-looking statements. There may be additional risks that neither PCSC nor Freenome presently know or that PCSC and

  4. Slide 4: SimpleScreen CRC v2 met all primary and secondary endpoints

    Endpoint CRC v1 (US Census adjusted) CRC v2 (US Census adjusted) N Value (95% CI) N Value (95% CI)I Pass (Yes/No) Sensitivity for CRC (Primary) 72 81.1% (71.3%, 88.1%) 89 80.4%, (70.2%, 87.7%) Yes Sensitivity for Advanced Precancerous Lesions (APL) (Primary) 2567 13.7% (12.4%, 15.0%) 1570 18.2%, (16

  5. Slide 5: SimpleScreen CRC v2 improved APL/HGD detection while maintaining CRC sensitivity in line with v1

    SimpleScreen CRC v2 improved APL/HGD detection while maintaining CRC sensitivity in line with v1 v2 detects more invasive Stage I T2 lesions, while detecting fewer Stage I T1 lesions (interpretability limited due to small sample size). US Census adjusted sensitivity by lesion category and CRC stage

  6. Slide 6: Performance improvements with SimpleScreen CRC v2 across all APL subtypes

    Performance improvements with SimpleScreen CRC v2 across all APL subtypes Advanced Precancerous Lesion (APL) Subtypes Subcategory Label Definition HGD/CIS APL 2.1 Adenoma with high-grade dysplasia (HGD) or carcinoma in situ (CIS), any size Villous / tubulovillous APL 2.2 Adenoma, villous growth patt

  7. Slide 7: SimpleScreen CRC v2 reduces modeled CRC cases and deaths while increasing life-years gained

    SimpleScreen CRC v2 reduces modeled CRC cases and deaths while increasing life-years gained per 100,000 people screened CRC cases CRC deaths Life-years gained Projected lifetime impact per 100K adults screened from ages 45 to 75 using the COSMOS-CRC model 1 Key Health Economic Model Inputs: Screenin

  8. Slide 8: Relative projected impact of APL sensitivity, adherence, and CRC sensitivity on health outcomes

    Relative projected impact of APL sensitivity, adherence, and CRC sensitivity on health outcomes Projected Lifetime Impact per 100K Screened CRC Cases (Fewer) CRC Deaths (Fewer) Life-Years Gained 1% Increase in APL Sensitivity -91 -32 +342 1% Increase in Adherence -39 -18 +206 1% Increase in CRC Sens

  9. Slide 9: Freenome Company Roadmap

    Freenome Company Roadmap

  10. Slide 10: Multiple value-driving catalysts on the horizon in CRC, lung, and PCD

    Multiple value-driving catalysts on the horizon in CRC, lung, and personalized cancer detection (PCD)* Early Access Program (EAP); Analytical/Clinical Validation (AV/CV): United States Preventive Services Task Force (USPSTF); Laboratory Developed Test (LDT); In Vitro Diagnostic (IVD) Anticipated Mil

  11. Slide 11: Freenome Appendix

    Freenome Appendix

  12. Slide 12: Test Versioning Programs

    Test Versioning Programs Final v2 Design DNA Extraction ✓ NGS Conversion ✓ NGS Platform (Library Prep, Multiplex, Capture, Sequencing) ✓ Process/reagent variability reduction (Mitigate degradation) ✓ Computational ✓ Assay Analytical Performance ~3x cfDNA molecule recovery compared to v1 Analytical P

  13. Slide 13: Modeled CRC v2 sensitivity when standardized to external study case mixes

    When standardized to external study case mixes, modeled CRC v2 sensitivity is 83% to 85% and APL remains near 18% Table below shows the estimated performance when considering the stage and APL subtype proportions from other blood-based CRC screening studies PREEMPT included a higher proportion of ea

  14. Slide 14: CRC and APL Sensitivity: Observed and US Census Adjusted Performance

    CRC and APL Sensitivity: Observed and US Census (IUP) Adjusted Performance Table 09.02.01.01.EC CRC-V2 as Index Test Evaluable Cohort (EC N=9001) Evaluation Endpoint Observed Fraction Observed Value (95% CI)I US Census Weighted Fraction US Census Weighted Value (95% CI)I Pass (Yes/No) CRC-V2 Primary

  15. Slide 15: High-Grade Dysplasia Sensitivity: Observed and US Census Adjusted Performance

    High-Grade Dysplasia Sensitivity: Observed and US Census (IUP) Adjusted Performance Table 09.02.02.01.HGD for CRC-V2 as Index Test HGD Set (HGD N=157) Evaluation Endpoint Observed Fraction Observed Value (95% CI)I US Census Weighted Fraction US Census Weighted Value (95% CI)I Pass (Yes/No) CRC-V2 Se

  16. Slide 16: Specificity: Observed and US Census Adjusted Performance

    Specificity: Observed and US Census (IUP) Adjusted Performance Table 09.03.01.01.EC Diagnostic Accuracy: Other Diagnostic Performance for CRC-V2 as Index Test Evaluable Cohort (EC N=9,001) Evaluation Endpoint Observed Fraction Observed Value (95% CI)I US Census Weighted Value (95% CI)I CRC-V2 Specif

  17. Slide 17: Additional Information about the Proposed Business Combination and Where to Find It

    Additional Information about the Proposed Business Combination and Where to Find It As previously disclosed, Perceptive Capital Solutions Corp. (“PCSC”), Freenome Holdings, Inc. (“Freenome”), StarNet Merger Sub I, Corp., a Delaware corporation and a wholly-owned subsidiary of PCSC, and StarNet Merge

Perceptive Capital Solutions — SPAC Merger (July 2026) on 6ix