Sartorius AG · XETR:SRT

Sartorius — Technical Presentation (March 2021)

57 slides from Sartorius's technical presentation, March 2021

  1. Slide 1: Biostat D-DCU: Your Fast Lane to Production

    Biostat® D-DCU Your “Fast Lane” to Production March 2021

  2. Slide 2: Content

    Content Introduction System Overview Hybrid Solution 2

  3. Slide 3: Drivers of Standardization for Stainless Steel Fermentation Systems

    Introduction Drivers of Standardization for Stainless Steel Fermentation Systems Key Drivers for Standardization ▪ Optimized and proven design ▪ Simplified and fast project execution ▪ Spare part availability ▪ Trained service technicians close to your operation ▪ Fast delivery ▪ Reduced costs ▪ Qui

  4. Slide 4: Biostat D-DCU Ideal Platform for

    Introduction Biostat® D-DCU Ideal Platform for ▪ Process development ▪ Process optimization ▪ Up-scale and down-scale ▪ Production 4

  5. Slide 5: Content

    Content Introduction System Overview Hybrid Solution 5

  6. Slide 6: Your Fast Lane to Production

    System Overview Biostat® D-DCU Your “Fast Lane” to Production Biostat® D-DCU ▪ Standardized, fully-featured SIP | CIP -System ▪ Microbial and cell culture applications ▪ Process development to production ▪ Single or Twin configuration ▪ Working volumes 10L, 20L, 30L, 50L, 100L, 200L ▪ Hybrid process

  7. Slide 7: System Overview

    System Overview Biostat® D-DCU System Overview Supply unit : Open frame design : Thermostat system Control Tower : Gas inlet : Single or Twin configuration : Exhaust : DCU control System Culture vessel : Touch panel : Flat top plate : Integrated gassing system : Bottom agitation system : Integrated

  8. Slide 8: Control Tower

    System Overview Biostat® D-DCU Control Tower ▪ Control Tower ▪ Single or Twin Configuration ▪ 19” Color display with touch screen ▪ Industrial PC ▪ Integrated amplifier rack ▪ Integrated Gassing Module : Airflow (Microbial applications) : O2-Enrichment (Microbial applications) : Gas Flow Ratio Contr

  9. Slide 9: Gassing Strategy: Airflow

    System Overview Biostat® D-DCU Gassing Strategy “Airflow” ▪ Rotameter for Sparger flow ▪ Intermitted sparging of air controlled by DOT controller ▪ Option: DOT control via mass flow controller 9

  10. Slide 10: Gassing Strategy: O2-Enrichment

    System Overview Biostat® D-DCU Gassing Strategy ▪“O2-Enrichment” • Gassing system with O2 enrichment capability via solenoid valve • Rotameter for Total Sparger flow • Intermitted O2 enrichment controlled via DOT controller • Option: Mass Flow Controller for Total Sparger Flow 10

  11. Slide 11: Gassing Strategy: Gas Flow Ratio Control

    System Overview Biostat® D-DCU Gassing Strategy Gas Flow Ratio Control” ▪ Air flow gassing system with O2 supplementation capability via mass flow controller for Air and O2 ▪ Continuous gas flow control of Air and Oxygen via DOT controller ▪ Rotameter for Total Sparger flow ▪ O2 Supplementation auto

  12. Slide 12: Gassing Strategy: Advanced Additive Flow

    System Overview Biostat® D-DCU Gassing Strategy ▪ Advanced Additive Flow” • Mixing of up to four gases Air, N2, O2 and CO2 • Sparger and Overlay gas outlets • Air, O2, N2, CO2 routed to Sparger, Air routed to Overlay • Intermitted or Continuous gas flow control of Air, O2 and N2 via DOT controller •

  13. Slide 13: Pumps

    System Overview Biostat® D-DCU Pumps ▪ Integrated Pumps ▪ Up to 6 integrated peristaltic pumps per vessel - 1 & 2 fixed speed, on/ off controlled - 3 & 4 fixed speed, on/ off controlled or speed controlled - 5 & 6 speed controlled ▪ Watson Marlow pump heads ▪ Available pumps - fixed speed WM 114, 5

  14. Slide 14: Human Machine Interface (HMI)

    System Overview Biostat® D-DCU Human Machine Interface (HMI) Human Machine Interface (HMI) ▪ Intuitive to use ▪ Touch panel ▪ 19” TFT display ▪ Swivel-mounted 14

  15. Slide 15: Operation-Main

    System Overview Biostat® D-DCU Operation-Main Control Tower –Operation Main ▪ Vessel process value overview at a glance for Twin systems ▪ Unit vessel detail process value overview ▪ Controller status indication manual auto auto cascade 15

  16. Slide 16: Operation-Trend

    System Overview Biostat® D-DCU Operation-Trend Control Tower -Operation Trend Display ▪ Up to 8 process variables ▪ Display time selectable : 1 hour : 12 hours : 72 hours ▪ Selectable ranges : for each process value : % value of measurement range ▪ Temporary storage only 16

  17. Slide 17: Operation-Calibration

    System Overview Biostat® D-DCU –Control Tower Operation-Calibration Control Tower -Operation Calibration ▪ Single or Group calibration ▪ User guided calibration routines ▪ For pH, DOT, turbidity, redox probes ▪ For pumps (flow totalizer) ▪ For gas solenoids (gas totalizer) 17

  18. Slide 18: Operation-Controller

    System Overview Biostat® D-DCU Operation-Controller Control Tower Operation – Controller ▪ Operations : Mode selection : Servo controller selection : Set point changes : Parameter changes * min./ max. out put * PID parameter * Dead band : Alarm setting 18

  19. Slide 19: Operation Advanced DOT Controller

    System Overview Biostat® D-DCU Operation Advanced DOT Controller Advanced pO2 Controller ▪ Up to 4 servo controllers ▪ Free user configurable polyline for parallel or sequential control ▪ Starting points are depending on DOT controller output ▪ Selectable starting points 19

  20. Slide 20: Operation-Phases

    System Overview Biostat® D-DCU Operation-Phases Control Tower -Operation Phases Sequence control with interlocks for ▪ Sterilization - Full vessel, incl. gas inlet and exhaust line - Empty vessel incl. gas inlet and exhaust line - 4-Valve addition array - Separate Exhaust filter line - Sampling valv

  21. Slide 21: Measurement and Control Capabilities

    System Overview Biostat® D-DCU Measurement and Control Capabilities Measurement Control Comments Agitation speed X X Servo drive Temperature X X Controlled via closed loop thermostat system pH_1 & pH_2 X X Controlled via CO2 (Solenoid) or MFC / Acid pump + Base pump (analogue or digital) pO2_1 & pO2

  22. Slide 22: Supply Unit

    System Overview Biostat® D-DCU Supply Unit Supply Unit Open frame design with... ▪ Gas inlet and Exhaust line ▪ Thermostat system - Closed-loop pressurized water system with circulation pump and heat exchanger for cooling - Heating : 10-30L: Alternatively via stainless steel heat exchanger (cupper s

  23. Slide 23: Supply Unit Components: 10-30L

    System Overview Biostat® D-DCU Supply Unit Components: 10-30L 1 Pressure control valve 2 Sight glass buffer system DMS 3 Temperature control system 3a Pressure compensation vessel 3b Safety valve 3c Circulation pump 3d Heat exchanger 3e Variant: Electrical heating 4 Variant: Dual exhaust filter line

  24. Slide 24: Supply Unit Components: 50-200L

    System Overview Biostat® D-DCU Supply Unit Components: 50-200L 1 Pressure control valve 2 Sight glass buffer system DMS 3 Temperature control system 3a Pressure compensation vessel 3b Safety valve 3c Circulation pump 3d Heat exchanger 3e Auxiliary electrical heater 3f Continues controlled steam valv

  25. Slide 25: Gas Inlet

    System Overview Biostat® D-DCU Gas Inlet Sparger aeration ▪ Stainless steel filter housing ▪ Bypass line if no Overlay line is installed ▪ Option: WIT ready filter housing Overlay aeration (Cell culture) ▪ Stainless steel filter housing ▪ Option: WIT ready filter housing 25

  26. Slide 26: Exhaust

    System Overview Biostat® D-DCU Exhaust Exhaust filter, basic (10-30L only) ▪ Stainless steel filter housing directly mounted on Exhaust cooler ▪ High foam sensor included Exhaust filter line (10-200L) Single filter line or Dual parallel filter line for in process sterilization Stainless steel filter

  27. Slide 27: Exhaust Cooler / Pressure Control Valve

    System Overview Biostat® D-DCU Supply Unit Exhaust Cooler / Pressure Control Valve Exhaust Cooler (10-30L) ▪ Mounted on culture vessel lid ▪ Shell and tube heat exchanger Exhaust Cooler (50-200L) ▪ Mounted in piping skid ▪ Shell and tube heat exchanger Pressure control valve ▪ Mounted in piping skid

  28. Slide 28: Culture Vessel

    System Overview Biostat® D-DCU Culture Vessel Culture vessel ▪ Vessel with bottom agitation ▪ Working volume 10, 20, 30, 50, 100, 200L ▪ Aspect ratio H : D (total): 2:1 or 3:1 ▪ Jacketed stainless steel vessel with torospherical bottom ▪ Longitudinal viewing window ▪ Vessel fabrication: PED or ASME

  29. Slide 29: Volume Overview

    System Overview Biostat® D-DCU Volume Overview Working Volume Total Volume Vessel description [L] [L] 10-2 | 10-3 4,5 – 10 | 3,5 - 10 14 | 15 20-2 | 20-3 5.5 – 20 | 3.5 – 20 29 | 31 30-2 | 30-3 6.5 – 30 | 5.5 – 30 42 | 41 50-2 | 50-3 13 – 50 | 13 - 50 74 | 77 100-2 | 100-3 24 – 100 | 24 - 100 152 |

  30. Slide 30: Culture vessel port overview

    System Overview Biostat® D-DCU Culture vessel port overview Description Vessel 10 L 20 L 30L 50 L 100 L 200 L 1 x sight glass for illumination 1 x sight glass for illumination 1 x spare port DN 50 1 x port for Exhaust 1 x port for CIP - connection (2x 200L) Lid 9 x 19 mm port 1 x port for Exhaust Li

  31. Slide 31: Scalability via geometrical similarity

    System Overview Biostat® D-DCU Scalability via geometrical similarity Scale 10-2 20-2 30-2 50-2 100-2 200-2 10-3 20-3 30-3 50-3 100-3 200-3 Total volume [L] 14 29 42 74 152 313 15 31 41 77 152 323 Working volume [L] 10 20 30 50 100 200 10 20 30 50 100 200 Min. working volume [L] 3,5 5,5 6,4 13 24 47

  32. Slide 32: Lid Lifting Device

    System Overview Biostat® D-DCU Lid Lifting Device Lid lifting device ▪ Available for vessel sizes from 30 – 200L ▪ Pneumatic operated ▪ Swivel and lockable Lid lifting device 200L 32

  33. Slide 33: Agitation Shafts

    System Overview Biostat® D-DCU Agitation Shafts Agitation shaft sealing Double mechanical seal w/ buffer fluid system ▪ For microbial and cell culture application ▪ Lubricated by pressurized condensate - Compressed Air pressurization Option: Low level alarm monitoring - Steam pressurization ▪ Sealin

  34. Slide 34: Agitation Motor

    System Overview Biostat® D-DCU Agitation Motor Agitation motor ▪ Bottom agitation system ▪ Brushless DC Servomotor ▪ Gear and maintenance free ▪ Easy to clean due to smooth surface 34

  35. Slide 35: Impeller for Microbial Application

    System Overview Biostat® D-DCU Impeller for Microbial Application 6-blade disk impeller The 6-blade disk impeller produces a flow which moves radially away from the shaft and has a high energy dissipation density. This impeller breaks up air bubbles effectively and thereby improves oxygen transport

  36. Slide 36: Impeller for Cell Culture Application

    System Overview Biostat® D-DCU Impeller for Cell Culture Application 3-blade segment impeller 3-blade segment impellers for cell culture applications, especially for shear sensitive cells and microcarrier cultures. The impeller creates an axial downward flow (upward flow version available as option)

  37. Slide 37: Aeration Devices

    System Overview Biostat® D-DCU Aeration Devices Microbial and Cell Culture application ▪ Ring sparger for 25 mm upper side port ▪ Holes from bottom Cell culture application ▪ Micro sparger for 25 mm upper side port ▪ Sintered stainless steel frit 20 µm Ring sparger µ-sparger 37

  38. Slide 38: Addition Devices: Needle Kits

    System Overview Biostat® D-DCU Addition Devices: Needle Kits Needle assembly for 19 mm port Product description ▪ For installation 19 mm top plate port ▪ Available as : 1-Channel assembly : 3-Channel assembly Operation: 1. Sterilization in an autoclave together with the addition bottles 2. Steriliza

  39. Slide 39: Addition Devices: SACOVA

    System Overview Biostat® D-DCU Addition Devices: SACOVA fety Containment Valve (Sacova) Product description ▪ Sterile valve for a 19 mm top plate port ▪ 1-Channel or 3-Channel assembly available ▪ For tubing 3,2 x 1,6 mm Sacova valve closed ▪ High containment class Operation: 1. Sterilization in an

  40. Slide 40: Addition Devices: 4-Valve Addition Array

    System Overview Biostat® D-DCU Addition Devices: 4-Valve Addition Array 4-Valve Addition Array, auto Product description ▪ Automatic resterilizable valve array for 25 mm port ▪ For multiple sterile connections during the process ▪ Perfect fit for connection of bags using BioWelder ▪ High containment

  41. Slide 41: Addition Devices: 4-Valve Addition Array, man

    System Overview Biostat® D-DCU Addition Devices: 4 Valve Addition Array, man 4-Valve Addition Array, man Product description ▪ Resterilizable valve array for 25 mm port ▪ Automatic bioreactor, manual vales for steam, condensate and addition ▪ For multiple sterile connections during the process ▪ Per

  42. Slide 42: Sampling

    System Overview Biostat® D-DCU Sampling Resterilizable Sampling Valve, Keofit Product description ▪ Resterilizable Keofit sampling valve for TC 50.5 sanitary port ▪ For multiple samplings during the process ▪ Manual steam valve ▪ Incl. Sterile sleeve ▪ Optional: Automatic sterilization via automatic

  43. Slide 43: Containment Sampling

    System Overview Biostat® D-DCU Containment Sampling Resterilizable Containment Sampling System Product description ▪ Resterilizable Keofit sampling valve for TC 50.5 sanitary port ▪ For multiple sterile samplings during the process ▪ Manual steam and condensate valves ▪ Containment sampling bottle ▪

  44. Slide 44: Single-use Sampling

    System Overview Biostat® D-DCU Single-use Sampling Takeone® Single-use sampling ▪ Aseptic sampling system ▪ Ready to use ▪ NO cleaning, preparation and sterilization ▪ Quickseal®: aseptic tube sealing system ▪ Sampling bag sealed & disconnected in seconds 44

  45. Slide 45: Drain Valve

    System Overview Biostat® D-DCU Drain Valve Drain valve Product description ▪ Radial sealed with TC connection ▪ Manual or automatic operated ▪ Sterile sleeve or Condensate line w/ steam trap ▪ Optional: Automatic sterilization via automatic steam and condensate valves or Drain valve (100-200L) trans

  46. Slide 46: Temperature Measurement of Condensate Lines

    System Overview Biostat® D-DCU Temperature Measurement of Condensate Lines Temperature measurement of condensate lines • For all relevant condensate lines in sterile area • Contact temperature sensors • Monitoring via Control Tower Contact temperature sensor at addition valve array 46

  47. Slide 47: Transfer Valve Group

    System Overview Biostat® D-DCU Transfer Valve Group Transfer valve group (10-30L) ▪ Automatic valves for steam and Condensate lines ▪ Manual transfer valve Transfer valve group (50-200L) ▪ Automatic valves for steam and Condensate lines ▪ Automatic transfer and drain valve Transfer valve group (10-3

  48. Slide 48: Cleaning In Place (CIP)

    System Overview Biostat® D-DCU Cleaning In Place (CIP) Cleaning In Place For the use of an external CIP system, culture vessel is used as a batching tank ▪ Available for vessel sizes 10 – 200L ▪ SIP / CIP header ▪ Automatic CIP sequence for: : Culture vessel : Aeration line : Exhaust line : 4-valve

  49. Slide 49: mobile CIP Unit

    System Overview Biostat® D-DCU mobile CIP Unit mobile CIP Unit ▪ One system for all vessel sizes (10L – 200L) ▪ High & low conductivity measurement ▪ Pump dry run protection ▪ Up two integrated dosing stations ▪ D-DCU communication interface for automated CIP sequence control 49

  50. Slide 50: Supporting Documentation

    System Overview Biostat® D-DCU Supporting Documentation Supporting Documentation Pre-order: ▪ Data sheet ▪ Arrangement plan ▪ Reference P&ID Post-order: ▪ Reference 3D model for room planning ▪ Operating manual ▪ Consumable list ▪ Qualification package - As build P&ID - Material certificates - Funct

  51. Slide 51: Content

    Content Introduction System Overview Hybrid Solution 51

  52. Slide 52: Hybrid Solutions

    Hybrid Solutions Hybrid Solutions Flexboy® or Flexel® bags can be connected to the BIOSTAT® D-DCU for corrective agent and feed addition to reduce cleaning effort. Together with our media preparation system FlexAct® MP and our cell harvest FlexAct® CH, a completely hybrid upstream process solution c

  53. Slide 53: Common Stainless Steel Bioreactor Design

    Hybrid Solutions Common Stainless Steel Bioreactor Design Common stainless steel bioreactor design ▪ Stainless steel storage vessels for corrective agents and feeds ▪ SIP / CIP requirements for all vessels ▪ High Steam / WFI requirements ▪ High capital investment 53

  54. Slide 54: Example of a Hybrid Solution: Stainless Steel Bioreactor with Single-Use Bags

    Hybrid Solutions Example of a Hybrid Solution Stainless Steel Bioreactor with Single-Use Bags Advantages ▪ Single-use bags for media storage and harvest ▪ SIP / CIP requirement for bioreactor only ▪ Low Steam / WFI requirements ▪ Fully flexible ▪ Reduced cleaning validation ▪ Lower capital investmen

  55. Slide 55: Example of a Hybrid Solution: How to Connect Single-Use Bags?

    Hybrid Solutions Example of a Hybrid Solution How to Connect Single-Use Bags? Tube welding, the easiest way to connect Operation ▪ Autoclave re-usable valve with TPE tubing ▪ SIP of addition / harvest group after connection of the autoclaved valve ▪ Connect TPE tubing from bag and valve by welding v

  56. Slide 56: Biostat D-DCU Hybrid Solutions

    Hybrid Solutions Biostat® D-DCU BioSealer ® TPE tube sealer FlexAct ® MP: Media Preparation Flexel ® CH: Cell Harvest Liquid storage bag Sartoclear ® Depth filter Flexboy® BioWelder ® Media storage bag Sartopore ® 2 TPE tube welder Liquid Filter 56

  57. Slide 57: Thank you.

    Thank you.