  1. Slide 1: Secure OPC Networking: OT to IT and the Cloud

    Slide 1: Secure OPC Networking: OT to IT and the Cloud

    SECURE OPC NETWORKING Xavier Mesrobian VP Sales and Marketing OT to IT and the Cloud xavier.mesrobian@skkynet.com

  2. Slide 2: Logistics

    Slide 2: Logistics

    • You are currently on mute • Please use Q&A to ask a question • Please use Chat for LOGISTICS assistance or if you have an immediate concern • Copies of the presentation and webinar link will be emailed to you SECURE INDUSTRIAL IoT REDEFINED 2

  3. Slide 3: Agenda

    Slide 3: Agenda

    • What are the risks of IIoT? • What are the risks associated with OPC? • OPC Networking • How the DataHub® helps • MQTT AGENDA • How the DataHub Helps • Live walk through of DataHub • Best practices • About Skkynet • Case Studies SECURE INDUSTRIAL IoT REDEFINED 3

  4. Slide 4: What are the risks in IIoT?

    Slide 4: What are the risks in IIoT?

    W H AT A R E T H E Department of Homeland security Honda Hacked: Japanese Car Giant Hacker ties to poison RISKS IN IIoT? confirms ransomware hit US gas pipeline Confirms Cyber Attack On Global water supply in Florida operator Operations Feb 18, 2020 June 10, 2020 Feb 8, 2021 Recent industrial cyber

  5. Slide 5: Governments get involved

    Slide 5: Governments get involved

    October 24, 2020 December 16, 2020 GOVERNMENTS GET INVOLVED In a rare joint release both NSA and CISA Revised Directive on Security of Network and Information recommend Systems (NIS2) immediate actions to Key Guideline: One or more reduce exposure DMZs are needed for the most secure, manageable, New

  6. Slide 6: Lessons learned

    Slide 6: Lessons learned

    LESSONS LEARNED Victims failed to implement robust segmentation between OT and IT Lack of OT / IT security 1. Compromise Windows-based assets on both the IT and OT networks: • HMIs, data historians, and polling servers • PLCs are rarely impacted 2. For international companies, impact is not geograph

  7. Slide 7: Purdue Model

    Slide 7: Purdue Model

    PURDUE MODEL SECURE INDUSTRIAL IoT REDEFINED 7

  8. Slide 8: Purdue Model

    Slide 8: Purdue Model

    PURDUE MODEL Vendors use VPNs to connect networks, assuming they are secure – they are not, bypassing firewalls SECURE INDUSTRIAL IoT REDEFINED 8

  9. Slide 9: OPC Networking

    Slide 9: OPC Networking

    OPC NETWORKING Security challenges

  10. Slide 10: OPC Networking: The Problem

    Slide 10: OPC Networking: The Problem

    OPC NETWORKING THE PROBLEM Plant Source Cloud OPC OPC DA/UA DA/UA Server Server Data direction Connection direction SECURE INDUSTRIAL IoT REDEFINED 10

  11. Slide 11: OPC Networking: The Problem (VPN)

    Slide 11: OPC Networking: The Problem (VPN)

    OPC NETWORKING THE PROBLEM VPN Plant Source Cloud OPC OPC DA/UA DA/UA Server Server • Connecting from a remote site requires an open an inbound firewall Data direction • VPNs have also proven inadequate Connection direction SECURE INDUSTRIAL IoT REDEFINED 11

  12. Slide 12: OPC Networking: Adding a DMZ

    Slide 12: OPC Networking: Adding a DMZ

    OPC NETWORKING ADDING A DMZ VPN Plant Source DMZ / IT Cloud OPC OPC OPC DA/UA Gateway UA Client • We still have an open inbound port in the Control network • Not secure Data direction Connection direction SECURE INDUSTRIAL IoT REDEFINED 12

  13. Slide 13: OPC Networking: How the DataHub Helps

    Slide 13: OPC Networking: How the DataHub Helps

    OPC NETWORKING H O W T H E D ATA H U B H E L P S (with DataHub) Plant Source DMZ / IT Cloud OPC DA/UA OPC Server UA Client DHTP OPC UA • Data is mirrored from the control network to the DMZ • Provides network isolation Data direction • Cloud OPC UA client connect via OPC UA Connection direction • Ne

  14. Slide 14: MQTT: One Potential Option

    Slide 14: MQTT: One Potential Option

    • MQTT is an OASIS standard MQT T network messaging protocol for the Internet of Things (IoT) • Publish/subscribe messaging transport • Lightweight and efficient • Bi-directional communications ONE POTENTIAL • Offers three defined quality of OPTION service levels • 0 - at most once • 1- at least onc

  15. Slide 15: OPC Networking Using MQTT

    Slide 15: OPC Networking Using MQTT

    OPC NETWORKING USING MQTT Plant Source Cloud MQTT MQTT client Broker • MQTT seems to be a right solution, but still requires network mapping Data direction • Most plant networks do not have access to the Internet Connection direction SECURE INDUSTRIAL IoT REDEFINED 15

  16. Slide 16: What About MQTT? Broker in the DMZ

    Slide 16: What About MQTT? Broker in the DMZ

    OPC NETWORKING W H AT A B O U T M Q T T ? Plant Source DMZ Cloud MQTT MQTT MQTT client Broker Client • Moving the Broker to the DMZ /IT • Requires the cloud service to connect to the broker Data direction • Most cloud services like Azure, AWS, Google IoT are not MQTT clients Connection direction SEC

  17. Slide 17: What About MQTT? Broker chaining

    Slide 17: What About MQTT? Broker chaining

    OPC NETWORKING W H AT A B O U T M Q T T ? Plant Source DMZ / IT Cloud MQTT MQTT MQTT client Broker/Client Broker • Moving the Broker to the DMZ / IT • MQTT Broker chaining is unreliable Data direction • Quality of service does not chain Connection direction • Connection status does not chain SECURE

  18. Slide 18: OPC Networking: How the DataHub Helps (MQTT)

    Slide 18: OPC Networking: How the DataHub Helps (MQTT)

    OPC NETWORKING H O W T H E D ATA H U B H E L P S (with DataHub) Plant Source DMZ / IT Cloud OPC DA/UA MQTT Server Broker DataHub DHTP DataHub MQTT • Data is mirrored from the control network to the DMZ • No open inbound firewall ports, no VPNs Data direction • Data is published to the cloud using MQ

  19. Slide 19: DataHub Live Walkthrough

    Slide 19: DataHub Live Walkthrough

    D ATA H U B ® LIVE WA L K T H O U G H SECURE INDUSTRIAL IoT REDEFINED 19

  20. Slide 20: Best Practices

    Slide 20: Best Practices

    • Keep your firewall ports closed • Eliminate all VPNs on your control network • Segment your control network • Level 1 – Level 5 with firewalls • Use DMZs whenever possible bridging between network levels BEST • Never provide internet access to the control PRACTICES network • Including mail servers

  21. Slide 21: DataHub Best Practices

    Slide 21: DataHub Best Practices

    • DataHub installation should only be accessible by Administrators • Users should be restricted from installation directories • On the tunnel master: • Disable “Accept plain-text connections” on service/port D ATA H U B ® • Install a valid certificate issued by a recognized certificate authority BES

  22. Slide 22: About Skkynet

    Slide 22: About Skkynet

    • 20,000+ installations in 86 countries • Used by 10 of 10 top automation providers worldwide • Certified AVEVA technology partner with ABOUT many case studies available on our website SKKYNET • OEM relationships with many hardware and software providers • Covering energy, discreet manufacturing, Cr

  23. Slide 23: Cogent DataHub

    Slide 23: Cogent DataHub

    C O G E N T D ATA H U B ® Connects to virtually any industrial system using OPC, Modbus TCP, MQTT, and ODBC to support networking, server- server bridging, aggregation, data logging, redundancy and any cloud connection https://cogentdatahub.com SECURE INDUSTRIAL IoT REDEFINED 23

  24. Slide 24: Case Studies

    Slide 24: Case Studies

    CASE STUDIES SECURE INDUSTRIAL IoT REDEFINED 24

  25. Slide 25: Real-time OPC A&E networking: Trans Anatolian Natural Gas Pipeline

    Slide 25: Real-time OPC A&E networking: Trans Anatolian Natural Gas Pipeline

    • Real-time monitoring and control of an 1,850 km pipeline • 7 compressor stations, Trans Anatolian Natural Gas Pipeline • 4 measuring stations, • 11 pigging stations, • 49 block valve stations, and • 2 off-take stations • DataHub middleware makes it possible to network over Real-time OPC 2.1 millio

  26. Slide 26: Secure OPC networking between power plants and company offices

    Slide 26: Secure OPC networking between power plants and company offices

    Energy Automation, Italy Secure OPC networking • Requirements called for highly between power secure means of data transmission, plants and with the minimal risk of break-ins company offices • Connect Power plants to Corporate network SECURE INDUSTRIAL IoT REDEFINED 26

  27. Slide 27: Tunnelling and aggregation to network OPC data through a firewall

    Slide 27: Tunnelling and aggregation to network OPC data through a firewall

    • Connect new control applications through several Tu n n e l l i n g a n d OPC stations to an existing SCADA network aggregation to • The OPC servers and SCADA systems were on network OPC data different computers, separated by a company firewall through a firewall • Each SCADA system needed to acce

  28. Slide 28: DataHub used for connectivity and integration

    Slide 28: DataHub used for connectivity and integration

    • Integrating the production data from all the city’s seven pumping stations for storage and DataHub used for analysis connectivity and • Reliable and secure integration • Read only with no write-back • Share the data with 3rd party systems • Required redundancy at several locations SECURE INDUSTRIA

  29. Slide 29: Thank You

    Slide 29: Thank You

    • Visit our website at cogentdatahub.com • Get more details on secure OPC THANK YOU networking: cogentdatahub.com/connect/secure-ot-it/ Secure Real-Time Data Communication for the Industrial IoT and Industrie 4.0 • Software downloads are available on our website • Check out our upcoming webinars cog

Source: Internet Archive copy of skkynet.com

More decks from Skkynet Cloud Systems, Inc.

All 12 Skkynet Cloud Systems decks