Blackline Safety — Investor Presentation (June 2019)
30 slides from Blackline Safety's investor presentation, June 2019
Slide 1: www.BlacklineSafety.com
www.BlacklineSafety.com
Slide 2: Who is Blackline Safety?
INTRODUCTION WHO IS BLACKLINE SAFETY? § Headquartered in Calgary, Alberta, Canada § Global connected safety technology leader behind G7 § Our talented team of designers and engineers create and manufacture everything in-house § In-house Safety Monitoring Center and Customer Care § We offer services
Slide 3: What is G7?
INTRODUCTION Standard Quad WHAT IS G7? Single § Work-everywhere, wearable, personal safety monitor with gas detection § 18 hours battery § 2-way texting § Deliver instant situational awareness § Manage fastest response § Intrinsically Safe
Slide 4: What is Bridge?
INTRODUCTION WHAT IS BRIDGE? § Portable satellite & cellular base station § Works with G7x to monitor your safety even when out of cell range § Delivers mass notifications § Is capable of connecting to up to five G7x devices with a range of 2km § 50 hours of battery -20 to 55C
Slide 5: Service Plans
INTRODUCTION SERVICE PLANS Self-monitored Blackline Monitored § Your team monitors your Blackline § Blackline Safety’s in-house Live account monitoring personnel monitor your team 24/7, 365 days a year § 99.5% of alerts responded to in under 1 minute
Slide 6: Hardware Details – G7x
HARDWARE DETAILS — G7x blacklinesafety Top lights @ Pending and warning @ Alerts @ LiveResponse Cartridge (Standard, SureSafe Single-gas or Quad-gas) @ SureSafe 4 blackline © LCD screen @ Speaker Metal belt clip SQ Up button P Down button OK button © Latch pull © Power button & Latch push button & M
Slide 7: Hardware Details – G7 Bridge
HARDWARE DETAILS – G7 BRIDGE Speaker Weatherproof Charging light enclosure SureSafe™ OK OK button Power button Up button Down button LCD screen Product label Base Charging port Sealing plug (removable) Side lights Alarm light
Slide 8: Mounting
MOUNTING Top of vehicle Dash On-site ALWAYS MAKE SURE G7 BRIDGE HAS A CLEAR VIEW OF THE SKY, ESPECIALLY WHEN OUTSIDE CELL COVERAGE
Slide 9: Power On / SureSafe Light
POWER ON SURESAFE LIGHT A blinking SureSafe Light means your device A solid SureSafe Light means you are is trying to connect. Don’t panic! It’s OK to connected to the Blackline Safety Network. have a blinking light for small amounts of time. Press the power button on G7 Bridge to Press the power bu
Slide 10: Emparejar el G7x
EMPAREJAR EL G7X El emparejamiento de nuevos dispositivos G7x es un paso de la configuración que solo se realiza una vez. Después del emparejamiento, el G7x y cualquier G7 Bridge de su organización se conectarán automáticamente el uno al otro cuando estén encendidos y dentro del rango necesario. G7x
Slide 11: Bump Test / Calibration
BUMP TEST / CALIBRATION Bump Test Calibration G7 will let you know it’s time to bump or calibrate upon start up. What do I do? Press and hold the up and down arrows to silence this reminder. Then, bump or calibrate using one of the methods on the next slide.
Slide 12: Bump Test / Calibration: two ways
BUMP TEST / CALIBRATION You can bump and calibrate in one of two ways: With G7 Dock: Manually: 1. Place G7 in dock 1. Press OK to access the menu 2. Close the lid 2. Use the up and down arrows to 3. Select bump test/calibration navigate to bump test from the menu 3. Select bump test 4. Let G7 Dock d
Slide 13: Wearing
WEARING Belt Chest DO NOT LEAVE G7 UNATTENDED WHEN POWERED ON, THIS CAN LEAD TO FALSE RED ALERTS
Slide 14: Yellow Pending Alarm
YELLOW PENDING ALARM YELLOW PENDING ALARM Fall detection Check-in timer No-motion What do I do? Are you OK? If yes, press the latch to return the device to normal function.
Slide 15: Yellow Pending Alarm escalation
YELLOW PENDING ALARM What happens if you don’t tell the device you’re OK? YELLOW PENDING ALARM RED ALERT If you don’t confirm you’re OK, the Yellow Pending Alarm escalates into Red Alert and notifies monitoring personnel. What do I do? Press and hold the up and down arrows to mute the device. Rememb
Slide 16: SOS Alert
SOS ALERT If you need to request help right away, you can trigger a SOS Alert. What do I do? How do I silence the alarm? Pull the latch! Press and hold the up and down arrows. Remember – this does not cancel the alert.
Slide 17: Red Gas Alert
RED GAS ALERT STEL TWA (SHORT TERM HIGH (TIME OL EXPOSURE ALERT WEIGHTED (OVER LIMIT) LIMIT) AVERAGE) G7 is informing you of something dangerous in your environment. For real-time customers, certain gas alerts will automatically generate a red alert and notify monitoring personnel. What do I do? Eva
Slide 18: Live Response
LIVE RESPONSE LIVERESPONSE The LiveResponse light will flash blue when monitoring personnel respond to your Alert using your company’s alert response protocol. When it shines on your device, it means someone will be contacting you to confirm you are OK. What do I do? Nothing! Wait for monitoring per
Slide 19: Yellow Warning Alarm
YELLOW WARNING ALARM YELLOW WARNING ALARM New message Network Low battery Bump Test Calibration • Low warning Connection alarm for gas Interruption • Sensor error • Under limit What do I do? After you’ve read the screen, press and hold the up and down arrows to silence the device Remember – Yellow w
Slide 20: Messaging
MESSAGING SENDING RECEIVING Sending a message: Receiving a message: 1. Press OK 1. Read your message 2. Select send message 2. Press and hold the up and down 3. Scroll to the message you want arrows for 3 seconds to send, press OK.
Slide 21: Configuration Modes: Entering a Mode
CONFIGURATION MODES Available Modes ENTERING A MODE What is seen on your device is dependent on your configuration profile in Blackline Live • Normal mode G7’s default for everyday operation • Pre entry For checking an atmosphere before entering, with or without pump. • SCBA For use with a supplied-
Slide 22: Configuration Modes: Extending a Mode
CONFIGURATION MODES EXTENDING A MODE When a mode timeout is reached, G7 will confirm that you’d like to stay in this mode. What do I do? Press the up arrow to extend the mode. Press the down arrow to exit the mode. If you do not confirm that you would like to extend your mode within 30 seconds, G7 w
Slide 23: G7 Multi-Pump Cartridge
G7 MULTI-PUMP CARTRIDGE Tubing Quick-connect Pump TURNING PUMP ON 1. Attach a multi-gas pump cartridge to G7 2. Enter a pumped mode, such as pre-entry or leak check 3. Perform a block test, following the steps on G7’s screen. 4. Pump will start automatically NOTE: if the block test fails, the device
Slide 24: Block Tests
BLOCK TESTS Block tests are performed to ensure your equipment is working properly before using pump to test the gas levels in an environment. Blackline’s G7 multi-pump cartridge has two types of block tests: AUTOMATIC BLOCK TEST MANUAL BLOCK TEST This is the block test that you can perform This is
Slide 25: Pump Menu Options
PUMP MENU OPTIONS When a G7 multi-pump cartridge is attached, a new secondary menu and main menu option appear. Pump options PUMP OPTIONS MENU The pump options menu is available from Back G7’s main menu, under settings. Sample time ON Hose length This is where you will set things such as: • Enabling
Slide 26: Power Off
POWER OFF Press and hold G7x’s power button for Press and hold G7 Bridge’s power button 3 seconds to turn the device off. for 3 seconds to power off. ! Always ensure that all connected G7x’s have been powered off before G7 Bridge. Before powering down, ensure you When all lights have stopped have a
Slide 27: Charging G7x
CHARGING G7x has an 18 hour battery life Remember to charge after every shift! What do I do? Put the clip into the base of the G7, then plug in the micro USB.
Slide 28: Charging G7 Bridge
CHARGING G7 Bridge has a 50 hour battery life Remember to charge after every shift! What do I do? Put the clip into the side of G7 Bridge then plug in the micro USB.
Slide 29: Questions?
QUESTIONS?
Slide 30: Support: support.BlacklineSafety.com
SUPPORT support.BlacklineSafety.com CUSTOMER CARE For technical support, please contact our Customer Care team. North America (24 hours) International (24 hours) Toll Free: 1-877-869-7212 +1-403-452-0327 support@blacklinesafety.com support@blacklinesafety.com