Hamamatsu Photonics K.K. · TSE:6965
Hamamatsu Photonics K.K — Technical Presentation (September 2020)
21 slides from Hamamatsu Photonics K.K's technical presentation, September 2020

Slide 1: Slide Preparation Training
Slide Preparation Training Hamamatsu Photonics K.K. 🄫🄫 Hamamatsu Photonics K.K. and its affiliates All Rights Reserved. 1

Slide 2: Index
Index ■ Slide preparation ■ Slide dimensions and requirements ■ Histology artefacts to avoid ■ Cutting tissue samples - Microtome ■ Slide labels ■ Coverslip ■ Barcode formats ■ References ■ Important notice This document is for training purposes only and is not a substitute for the ‘Instructions for

Slide 3: Slide Preparation
Slide Preparation Regardless of the whole slide scanner used, slide preparation is the key to achieving high quality digital images. Since poor quality slide preparation could lead to non-diagnosable images, the following information outlines the optimum slide preparation that will help attain the h

Slide 4: Slide dimensions and requirements
Slide dimensions and requirements In addition to slide preparation, it is also Label Area Tissue Placement Area important to make sure that the slides match the scanner specifications, for example: 24.7 mm - 26.5 mm Slides should not be chipped, cracked or scratched. Corner may be clipped, howev

Slide 5: Histology artefacts to avoid
Histology artefacts to avoid During slide preparation, please ensure the slides do not contain the following: Dirt Tissue folds Tissue overhanging Scratches Excessive mounting media Marker on slide Air bubbles Damaged microtome blade We will now cover each of these artefacts in more

Slide 6: Dirt
Dirt If dirt appears on the surface of the slide, there is a risk that the scanner will focus on this rather than the tissue, causing unfocused areas. 🄫🄫 Hamamatsu Photonics K.K. and its affiliates All Rights Reserved. 6

Slide 7: Tissue folds
Tissue folds Tissue folds can compromise image quality. It is therefore important to minimize the occurrence of these folds during slide preparation. We are aware however, that there are variables in tissue types and the temperatures at which they can be optimally cut can cause the occurrence of tis

Slide 8: Tissue overhanging
Tissue overhanging In order for the scanner to focus on the tissue, it requires the coverslip to be positioned correctly on all sections. 🄫🄫 Hamamatsu Photonics K.K. and its affiliates All Rights Reserved. 8

Slide 9: Scratches
Scratches Please ensure that there are no visible scratches on the surface of the slide. 🄫🄫 Hamamatsu Photonics K.K. and its affiliates All Rights Reserved. 9

Slide 10: Excessive mounting media
Excessive mounting media Excessive mounting media can result in reduced image quality, therefore please avoid applying too much mounting media during preparation. 🄫🄫 Hamamatsu Photonics K.K. and its affiliates All Rights Reserved. 10

Slide 11: Pen marks
Pen marks Please avoid using pen to mark individual section(s) of the slides. This can cause the scanner to focus on the markings rather than the tissue sample. Hamamatsu recommend using digital marking tools to prevent this. 🄫🄫 Hamamatsu Photonics K.K. and its affiliates All Rights Reserved. 11

Slide 12: Air bubbles
Air bubbles Please be aware, if air bubbles occur during slide preparation, there is a risk that the scanner will focus on these bubbles rather than the tissue sample. 🄫🄫 Hamamatsu Photonics K.K. and its affiliates All Rights Reserved. 12

Slide 13: Microtome
Microtome When cutting tissue samples, please make sure that the following steps are carried out: Microtome should be placed on a steady bench to prevent any movement while cutting the tissue. Any movement may cause vibration during tissue sectioning. There should be an optimal blade tilt. Bla

Slide 14: Slide labels
Slide labels Slides with overhanging or lifting labels will cause the scanner to drop the slide. To prevent the scanner from stopping, it is important to make sure that the slide label is positioned correctly on the label area, without any overhanging sections. This document is for training purposes

Slide 15: Slide labels
Slide labels Do not stack labels (this will cause the loader to become unbalanced). Make sure the label is not peeling. No excess adhesive residue. Place the label on the designated area. The label must be placed at the top of the slide. 🄫🄫 Hamamatsu Photonics K.K. and its affiliates…

Slide 16: Coverslip
Coverslip All slides must be cover-slipped. It is advised to use glass cover slips rather than plastic, to avoid scratches on the surface which compromise image quality. No oil should be used – this is likely to damage the system. No coverslips should be overhanging since this will lead to s

Slide 17: Barcodes
Barcodes Example of barcode type supported by NanoZoomer * Barcode name Type Default Note CODE-39 1D Enable CODE-128 1D Enable CODE-2-of-5 Interleaved 1D Enable Coda bar 1D Enable EAN-8 1D Enable EAN-13 1D Disable Patch Codes 1D Disable UPC-A 1D Disable UPC-E 1D Enable Barcode Option Datamatrix 2D D

Slide 18: Barcodes
Barcodes Example of Barcode Option Datamatrix Example of Barcode Option QR Code supported by NanoZoomer * supported by NanoZoomer * Figure 1 Figure 2 * This information is cited from the NanoZoomer instructions for use. This document is for training purposes only and is not a substitute for the ‘Ins

Slide 19: References
References 1. Evans AJ, Salama ME, Henricks WH, Pantanowitz L. Implementation of Whole Slide Imaging for Clinical Purposes: Issues to Consider From the Perspective of Early Adopters. Arch Pathol Lab Med. 2017;141(7):944-959. doi:10.5858/arpa.2016-0074-OA 2. Hashimoto, Noriaki. (2016). Practical Appl

Slide 20: Important Notice
Important Notice Following products are CE marked under EU’s In Vitro Diagnostics Directive (IVDD) for in vitro diagnostic use: NanoZoomer-SQ, NanoZoomer S210, NanoZoomer S60, NanoZoomer S360 including optional software e.g. NDP.view2 (U12388-21), NDP.view2 plus (U12388-22) and NDP.serve3 software (

Slide 21: Cat. No. SBIS0131E01 SEP/2020 HPK 🄫🄫 Hamamatsu Photonics K.K. and its affiliates All Rights
Cat. No. SBIS0131E01 SEP/2020 HPK 🄫🄫 Hamamatsu Photonics K.K. and its affiliates All Rights Reserved. 21
Source: Internet Archive copy of nanozoomer.hamamatsu.com
More decks from Hamamatsu Photonics K.K.
FY2026 Earnings Presentation44 slides · November 2026
Q3 FY2026 Earnings Presentation32 slides · August 2026
Q2 FY2026 Earnings Presentation29 slides · May 2026
Q1 FY2026 Earnings Presentation16 slides · February 2026
FY2025 Earnings Presentation51 slides · November 2025
Q3 FY2025 Earnings Presentation28 slides · August 2025