  1. Slide 1: POLESTAR Trial

    Slide 1: POLESTAR Trial

    POLESTAR Trial Project to look for early discharge in patients undergoing TAVI with ACURATE 30-day results of an international early discharge program By Joris Ooms, MD. On behalf of the POLESTAR investigators CAUTION: In Europe, ACURATE neo2 Aortic Valve System is CE-marked. In the USA, ACURATE neo

  2. Slide 2: Potential conflicts of interest

    Slide 2: Potential conflicts of interest

    Potential conflicts of interest Speaker's name : Joris Ooms, MD ☑ I have the following potential conflicts of interest to declare: Receipt of grants / research support: Institutional grant from Boston Scientific CAUTION: In Europe, ACURATE neo2 Aortic Valve System is CE-marked. In the USA, ACURATE n

  3. Slide 3: Why this study?

    Slide 3: Why this study?

    Why this study? • TAVI in severe aortic stenosis (AS) has matured • Potential for early discharge (ED) is evident • Prospective patient selection with use of risk factors for non-ED could improve ED-pathways • Not all valve platforms are equally represented in ED studies CAUTION: In Europe, ACURATE

  4. Slide 4: What did we study?

    Slide 4: What did we study?

    What did we study? • Aim: evaluation of the safety and feasibility of ED in patients selected pre-TAVI using the ACURATE NEO valve • International prospective observational single-arm study (NCT03910751) • ED: discharge to patients home environment ≤48hrs • Main outcomes are VARC III defined safety

  5. Slide 5: How was the study executed?

    Slide 5: How was the study executed?

    How was the study executed? • Conducted in Netherlands, Belgium, Canada, United Kingdom • Pre-TAVI identification of AS patients suitable for ED • Inclusion: ≥18yrs, severe AS, eligible for TF-TAVI with ACURATE • Exclusion: LVEF<35%, severe MR, PHT, complex CAD, high degree AV-block/RBBB, BMI>35, CO

  6. Slide 6: What are the essential results? – Baseline & Discharge

    Slide 6: What are the essential results? – Baseline & Discharge

    What are the essential results? – Baseline & Discharge Baseline Overall ED Non-ED p-value n = 252 n= 173 n = 79 Age - yrs 82 [78-85] 82 [78-84] 82 [76-85] 0.40 Overall Non-ED Female 133 (53) 89 (51) 44 (56) 0.53 100% *Death (1%) *Social situation (1%) Patient not willing (2%) BMI – kg/m2 27 ± 3.9 27

  7. Slide 7: What are the essential results? – Primary Outcomes

    Slide 7: What are the essential results? – Primary Outcomes

    What are the essential results? – Primary Outcomes Clinical outcomes Overall 30 Landmark 2 Landmark >48hr until 30-days days days N = 251 N = 250 Non early discharge Early discharge p-value Safety1 34 (13.5) 19 (7.6) 7 (9.0) 12 (7.0) - OR 0.84 [0.31-2.26] 0.73 Efficacy2 39 (15.5) 37 (14.9) 12 (15.4)

  8. Slide 8: What are the essential results? – Clinical Outcomes

    Slide 8: What are the essential results? – Clinical Outcomes

    What are the essential results? – Clinical Outcomes Death Major Bleeding Stroke Major Vascular New PPM % % % % % 10 10 10 10 10 8 8 8 8 8 6 6 6 6 6 4 4 4 4 4 2 2 2 2 2 0 0 0 0 0 30D <48h >48h 30D <48h >48h 30D <48h >48h 30D <48h >48h 30D <48h >48h Rehospitalization - 30 days Conduction % • Overeall

  9. Slide 9: What are the essential results? – Neo and Neo 2

    Slide 9: What are the essential results? – Neo and Neo 2

    What are the essential results? – Neo and Neo 2 Clinical Outcomes – 30 Days TTE: Aortic regurgitation post TAVI % 25 100% Neo Neo 2 P=0.45 20 80% 15 60% 10 40% 5 20% 0 0% Neo Neo 2 < Mild Mild Moderate CAUTION: In Europe, ACURATE neo2 Aortic Valve System is CE-marked. In the USA, ACURATE neo2 is an

  10. Slide 10: Why is this important?

    Slide 10: Why is this important?

    Why is this important? • One third was discharged after 48hrs with low readmission rates • No penalty in composite endpoints between discharge groups • Low PM rates, conduction remains important factor in decision for ED • POLESTAR identifies targets for length of stay reduction • Limitations: Selec

  11. Slide 11: The essentials to remember

    Slide 11: The essentials to remember

    The essentials to remember • Early discharge < 48 hours after TAVI with ACURATE Neo platform is safe & feasible in selected patients • Refined selection criteria for early discharge after TAVI in elderly patients requires further research CAUTION: In Europe, ACURATE neo2 Aortic Valve System is CE-ma

  12. Slide 12: PCRonline.com

    Slide 12: PCRonline.com

    PCR PCRonline.com

  13. Slide 13: All trademarks are property of their respective owner. CAUTION: The law restricts these devices

    Slide 13: All trademarks are property of their respective owner. CAUTION: The law restricts these devices

    All trademarks are property of their respective owner. CAUTION: The law restricts these devices to sale by or on the order of a physician. Indications, contraindications, warnings and instructions for use can be found in the product labelling supplied with each device. Products shown for INFORMATION