Business
Teuton Resources Reports Completion of IP Survey on Harry Property
(TheNewswire) Vancouver, Canada –– TheNewswire - Teuton Resourc...

About this update from Teuton Resources Corp.
[{"type":"text","content":"Teuton Resources Reports Completion of IP Survey on Harry Property\n \n \n (TheNewswire)\n \n \n \n \n \n \n \n \n \n Vancouver, Canada ––\n \n \n TheNewswire -\n \n \n Teuton Resources Corp.\n \n \n (“Teuton” or “the Company”)\n(TSXV:TUO)\n \n \n (OTC:TEUTF)\n \n \n (Frankfurt:TFE)\n \n \n has received another progress report from its\noptionee, Optimum Ventures inc., (“Optimum”) stating that it has\nnow completed an induced polarization (IP) and magnetic geophysical\nsurveying on the Harry property located north of Stewart, BC, within\nthe Golden Triangle.\n \n \n \n \n Optimum reports that IP surveying has yielded new and\nimportant information that will help guide drilling and surface\nexploration work. This survey was carried out to outline known\nstructures and uncover unknown structures due to overburden in the\narea. This has outlined areas of sulphide concentrations as well as\nareas of quartz – sulphide stock works. The final survey report has\ndemonstrated the program's success by outlining numerous\nanomalies.\n \n \n \n \n IP Survey Highlights (see URL at the end of the release\nfor a Plan Map showing IP Results)\n \n \n :\n \n \n \n \n -Twenty-seven chargeability anomalies (first to third\norder) have been identified, which are interpreted and presented in\nthe attached map.\n \n \n \n \n -Drilling targets can now be selected from the first\npriority on the 2D sections for future exploration follow-up.\n \n \n \n \n -The east side of the Grid (L7E, L8E, and L9E), depict\nthe strongest chargeability at both extents of the profiles.\n \n \n \n \n -The western profiles (L5E, L6E, and L11E) depict the\nstrongest chargeability in the central parts of the sections\n \n \n \n \n -Discovery of new zone Ursula South\n \n \n \n \n -\n \n \n The first\nand second priority zones are relatively shallow compared to the third\npriority zone, which extends to a depth of more than 300m. Aside from\nanomalous zones, overall chargeability is in the high range, which\nreflects major amounts of pyrite and high sulphide percentage in the\nsurvey area. The chargeability zones are generally controlled by the\nsub-vertical faults.\n \n \n \n \n The IP resistivity models display a\nsubsurface resistivity variation range from 200Ωm to 20000+Ωm. The\nsurvey area gene...