Business
First Energy Metals Intersects 12.1 metre wide cobalt-copper mineralization at Phyllis Cobalt Property in Ontario
VANCOUVER, April 30, 2019 /CNW/ - First Energy Metals Ltd. (CSE: FE) (the "Company) is pleased to announce assay results for the Phase 1 Drill Program at its Ph

About this update from Linear Minerals Corp.
[{"type":"text","content":" VANCOUVER, April 30, 2019 /CNW/ - First Energy Metals Ltd. (CSE: FE) (the \"Company) is pleased to announce assay results for the Phase 1 Drill Program at its Phyllis Cobalt Property (the \"Phyllis Property\") in Ontario. Drill Hole PC-19-02 intersected 12.1m with 0.10% Cobalt (Co), 0.79% Copper (Cu), and 0.08% Nickel (Ni); and Drill Hole 19-01 intersected 4.4m with 0.09% Co, 0.54% Cu, 0.16% Ni. Highlights of drill results are presented in the following table: Table: Drilling Results Highlights Hole ID To (m) From (m) Width* (m) Co (%) Cu (%) Ni (%) PC-19-01 10.5 14.9 4.4 0.09 0.54 0.16 including 10.5 12.5 2 0.1735 1.032 0.07485 PC-19-02 12.1 24.2 12.1 0.1 0.79 0.08 including 14.2 18.6 4.4 0.23 0.75 0.17 and 12.1 14.2 2.1 0.004 2.09 0.023 *Reported widths are drill intercept widths and do not represent true thickness. True thickness is not known at this time. The program comprised of two AW size (1.9 inches or 48.26 mm ID) diamond core drill holes, totalling eighty-two (82) metres drilled by Ombabika Development Corporation of Nipigon, Ontario. The first drill hole (PC-19-01) was drilled at 60-degree angle towards 070-degree azimuth to a depth of 40 m, and the second hole (PC-19-02) was drilled vertical to a depth of 42 m. A total of twenty-nine (29) samples were taken from the core for cobalt-nickel-copper (Co-Ni-Cu) analysis. These samples were submitted to Activation Laboratories in Thunder Bay, Ontario, and were tested either at its Thunder Bay or Ancaster labs in Ontario. Actlabs is an independent group of laboratories accredited to both ISO 17025 with CAN-P-1579 for specific registered tests. The recovery percent per each hole was 76% for PC-19-01 and 79% for hole PC-19-02. The samples for this program were assayed using the following ACTLABS packages:- Code 8 AR ICP-MS: A 0.5 g sample is digested in aqua regia and diluted volumetrically to 250 ml with 18 megaohm water. CANMET reference materials for the appropriate elements are digested the same way and are used as a verification standard(s). Samples are analyzed on a Varian Vista 735 ICP-OES or ICP-MS.(Source: Actlabs website). The program was aimed at testing the central Phyllis Cobalt Zone below surface to see the depth and size of the gabbroic intrusion and related cobalt -copper-nickel mineralization. All core samples were logged and split by hydrau...