Business
Hanstone Gold Announces Additional High Grade Intercepts Including an Outstanding Interval of 113.70 G/T Gold over 1.28 Metres at Its Flagship Doc Property in BC's Prolific Golden Triangle
Vancouver, British Columbia--(Newsfile Corp. - December 3, 2020) -   Hanstone Gold Corp. ...

About this update from Hanstone Gold Corp.
[{"type":"text","content":"Hanstone Gold Announces Additional High Grade Intercepts Including an Outstanding Interval of 113.70 G/T Gold over 1.28 Metres at Its Flagship Doc Property in BC's Prolific Golden TriangleVancouver, British Columbia--(Newsfile Corp. - December 3, 2020) -  Hanstone Gold Corp. (TSXV: HANS) (\"Hanstone\" or the \"Company\") is pleased to provide assay results from the balance of the Company's drill holes completed in the 2020 drill program at the Company's Doc Property, located in British Columbia's prolific Golden Triangle Mining District.Table 1: Doc Zone Gold Intersection Highlights Drill HoleInterval (m)Grade Au (g/t)DC-20-04 8.126.35including0.6053.10DC-20-057.7111.51including1.1750.12DC-20-0613.2812.01including1.28113.70 Ray Marks, President and Chief Executive Officer of Hanstone Gold, stated:\"This second round of 2020 drill results further confirms the existence of high grade gold mineralization on the Doc Property. These results have exceeded management's expectations having returned exceptional intersections of gold. The reported gold intercepts support management's previous geologic expectations that the Doc Property hosts significant mineralized systems, both near surface and at greater depths.\"Data from this round of results from the remaining drill holes totalling 1,251 metres has exceeded the positive results from the first set of drill holes announced on November 12, 2020. Drillhole assay results of gold intersection highlights from this final round of 2020 drilling, presented below, include:Table 2: Significant Doc Zone Drilling Intersections - Average Assay GradesHole NumberAzimuthDipAvg Grade Au (g/t)Avg Grade Ag (g/t)Cu (ppm)Zn (ppm)From Depth (m)To Depth (m)Interval (m)DC-20-04215°-60°6.3569.4877.608.12including10.5871.0074.503.50and53.10198.90416.0072.9073.500.60and17.6876.90920.9076.3077.000.70DC-20-05215°-75°11.5142.00129.83137.007.17including50.12176.70133.23134.401.17DC-20-06225°-70°2.7861.1061.550.4512.0152.70323.60229.10119.00132.2813.28including8.47119.00119.500.50and113.70495.30838.00728.10131.00132.281.28 Notes:Au analysis is by fire assay with Gravimetric finish (FA/Gravimetric 2 AT)Ag analysis is by aqua regia digestion ICP multi-element analysis (TSL Labs Method ICP-MS Aqua Regia)Ag values >100 ppm were reanalyzed by fire assay with Gravimetric fini...